header advert
Results 1 - 6 of 6
Results per page:

Aims

The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral.

Methods

The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 80 - 80
10 Feb 2023
Bin Ghouth S Williams S Reid S Besier T Stott N Handsfield G
Full Access

Cerebral palsy (CP) is a neural condition that impacts and impairs the musculoskeletal system. Skeletal muscles, particularly in the lower limb, have previously been shown to be significantly reduced in volume in CP compared to typical controls. Muscle volume is a gross measure, however, and does not capture shape characteristics which—if quantified—could offer a robust and novel assessment of how this condition impacts skeletal muscle form and function in CP. In this study, we used mathematical shape modelling to quantify not just size, but also the shape, of soleus muscles in CP and typically developing (TD) cohorts to explore this question.

Shape modelling is a mathematical technique used previously for bones, organs, and tumours. We obtained segmented muscle data from prior MRI studies in CP. We generated shape models of CP and TD cohorts and used our shape models to assess similarities and differences between the cohorts, and we statistically analysed shape differences.

The shape models revealed similar principal components (PCs), i.e. the defining mathematical features of each shape, yet showed greater shape variability within the CP cohort. The model revealed a distinct feature (a superior –> inferior shift of the broad central region), indicating the model could identify muscular features that were not apparent with direct observation. Two PCs dominated the differences between CP and TD cohorts: size and aspect ratio (thinness) of the muscle.

The distinct appearance characteristic in the CP model correspond to specific muscle impairments in CP to be discussed further. Overall, children with CP had smaller muscles that also tended to be long, thin, and narrow. Shape modelling captures shape features quantitatively, which indicate the ways that muscles are being impacted in CP. In the future, we hope to tailor this technique toward informing diagnosis and treatments in CP.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 924 - 932
1 Jul 2015
Lee MC Ha C Elmallah RK Cherian JJ Cho JJ Kim TW Bin S Mont MA

The aim of this study was to assess the effect of injecting genetically engineered chondrocytes expressing transforming growth factor beta 1 (TGF-β1) into the knees of patients with osteoarthritis. We assessed the resultant function, pain and quality of life.

A total of 54 patients (20 men, 34 women) who had a mean age of 58 years (50 to 66) were blinded and randomised (1:1) to receive a single injection of the active treatment or a placebo. We assessed post-treatment function, pain severity, physical function, quality of life and the incidence of treatment-associated adverse events. Patients were followed at four, 12 and 24 weeks after injection.

At final follow-up the treatment group had a significantly greater improvement in the mean International Knee Documentation Committee score than the placebo group (16 points; -18 to 49, vs 8 points; -4 to 37, respectively; p = 0.03). The treatment group also had a significantly improved mean visual analogue score at final follow-up (-25; -85 to 34, vs -11 points; -51 to 25, respectively; p = 0.032). Both cohorts showed an improvement in Western Ontario and McMaster Osteoarthritis Index and Knee Injury and Osteoarthritis Outcome Scores, but these differences were not statistically significant. One patient had an anaphylactic reaction to the preservation medium, but recovered within 24 hours. All other adverse events were localised and resolved without further action.

This technique may result in improved clinical outcomes, with the aim of slowing the degenerative process, leading to improvements in pain and function. However, imaging and direct observational studies are needed to verify cartilage regeneration. Nevertheless, this study provided a sufficient basis to proceed to further clinical testing.

Cite this article: Bone Joint J 2015;97-B:924–32.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 432 - 432
1 Dec 2013
Moon Y Kim K Han S Choi C Lee MC Bin S
Full Access

Purpose:

To investigate treatment patterns and efficacy of postoperative strong opioids in patients who underwent total knee arthroplasty (TKA) in Korea

Methods:

A prospective, non-interventional study of 301 patients who underwent TKA and received strong opioids following patient controlled analgesia (PCA) was conducted by reviewing patient charts and diaries from 19 teaching hospitals. Clinical characteristics, strong opioid treatment patterns, efficacy of strong opioid on a scale of 0–10, and opioid-related adverse events (AEs) were investigated during hospitalization and at first outpatient visit. Safety analysis was conducted on 301 patients, and efficacy analysis was conducted on full analysis set (FAS) which consisted of all the patients who had at least 1 efficacy result among 301 patients.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 122 - 122
1 Mar 2010
Oh J Oh C Kim S Jo K Bin S Yoon J
Full Access

We evaluated the outcome of hemiarthroplasty with bone block graft and low profile prosthesis (Aequalis® fracture prosthesis) for the comminuted proximal humerus fractures. Sixteen low profile prostheses were used since July 2004, and 11 patients were followed-up for average 19.9 (12–30) months. Their mean age was 67.3 (52–78) years. Cemented stem in all cases. Two bone block graft and cancellous chip bone from resected humeral head. Ten cases for Neer type 4 fracture, one case for type 3 fracture. During 6 weeks, abduction brace with neutral rotation position was maintained. Passive and active range of motion exercise started at 6 weeks. Pain and satisfaction visual analog scale (VAS), range of motion, and modified UCLA score for hemiarthroplasty were evaluated at every visit. Radiography was also checked for stem position, loosening, and tuberosity union.

Mean pain VAS was 2.7 (0–5), and mean satisfaction VAS was 8.4 (5–10). Mean active forward flexion was 137o (90–170), external rotation at side was 45.5o (25–70), and internal rotation at back was T10 (T7-L1). Modified UCLA score was 19 (12–30) at final visit. All stems were stable, and there were no loosening at the final follow-up. All tuberosities were united except two tuberosity absorptions. One complication case was infection.

The outcome of hemiarthroplasty with bone block graft and low profile prosthesis was comparable to other implants for comminuted proximal humerus fractures. This system had unique advantages for tuberosity union. Further study with more patients and longer follow-up period are necessary to clarify the effectiveness of this prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1304 - 1310
1 Oct 2008
Kim T Lee D Bin S

We carried out a prospective study to assess the clinical outcome, complications and survival of the NexGen Legacy posterior-stabilised-Flex total knee replacement (TKR) in a consecutive series of 278 knees between May 2003 and February 2005. Mean follow-up for 259 TKRs (98.2%) was 3.8 years (3.0 to 4.8). Annual follow-up showed improvement in the Knee Society scores (paired t-test, p < 0.05). At the last follow-up, the mean maximum flexion was 135° (110° to 150°). Two knees showed radiolucent lines, but revision was not required because the patients were asymptomatic. Revision was required in one case because of infection, but there were no prosthesis-related revisions. There were no other complications. The estimated survival rate at four years with revision for any reason and prosthesis-related problems was 99.6% and 100%, respectively.

This relatively large study indicates that the legacy posterior stabilised-Flex design provides excellent short-term outcome but warrants ongoing evaluation to confirm the long-term durability and functioning of the implant.