header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 115 - 115
1 Apr 2019
Bock R Cullen D McEntire B More K Leonard D Bal BS
Full Access

Introduction

The osteogenic capability of any biomaterial is governed by a number of critical surface properties such as surface energy, surface potential, and topography. Prior work suggested that the Si-Y-O-N phase(s) present in the form of a thin (<150 nm), interrupted film at the surface of an annealed silicon nitride bioceramic may be responsible for an observed upregulation of osteoblastic activity due to passive surface properties and dissolution of chemical species. In this study high- resolution analytical electron microscopy was utilized to identify the Si-Y-O-N phase present on the annealed silicon nitride surface, and dissolution studies were employed to elucidate mechanisms of the material's favorable cell interactions.

Materials and Methods

Si3N4 discs (12.7 mm diameter × 1 mm thick) containing Y2O3 and Al2O3 sintering aids were processed using conventional techniques and subsequently subjected to annealing in a nitrogen atmosphere. Pre-cultured SaOS-2 osteosarcoma cells at a concentration of 5 × 105 cells/ml were seeded onto sterile polished nitrogen-annealed Si3N4 discs in an osteogenic medium consisting of DMEM supplemented with about 50 µg/mL ascorbic acid, 10 mM β-glycerol phosphate, 100 mM hydrocortisone, and 10% fetal bovine calf serum. The samples were incubated for up to 7 days at 37°C with two medium replenishments. Transmission electron microscopy (TEM) images were acquired from focused ion beam (FIB)-prepared samples using a Hitachi HF-3300 TEM (300 kV). Scanning transmission electron microscopy (STEM) images were recorded using a Nion UltraSTEM 100 (60 kV). STEM high-angle annular dark-field (HAADF) imaging and energy dispersive X-ray spectroscopy (EDS) analyses were performed on a JEOL JEM2200FS (200 kV) equipped with a third-order CEOS aberration corrector and a Bruker XFlash silicon drift detector.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 116 - 116
1 Apr 2019
Bock R Pezzotti G Zhu W Marin E Rondinella A Boschetto F McEntire B Bal BS
Full Access

Introduction

Support of appositional bone ingrowth and resistance to bacterial adhesion and biofilm formation are preferred properties for biomaterials used in spinal fusion surgery. Although polyetheretherketone (PEEK) is a widely used interbody spacer material, it exhibits poor osteoconductive and bacteriostatic properties. In contrast, monolithic silicon nitride (Si3N4) has shown enhanced osteogenic and antimicrobial behavior. Therefore, it was hypothesized that incorporation of Si3N4 into a PEEK matrix might improve upon PEEK's inherently poor ability to bond with bone and also impart resistance to biofilm formation.

Methods

A PEEK polymer was melted and compounded with three different silicon nitride powders at 15% (by volume, vol.%), including: (i) α-Si3N4; (ii) a liquid phase sintered (LPS) ß-Si3N4; and (iii) a melt-derived SiYAlON mixture. These three ceramic powders exhibited different solubilities, polymorphic structures, and/or chemical compositions. Osteoconductivity was assessed by seeding specimens with 5 × 105/ml of SaOS-2 osteosarcoma cells within an osteogenic media for 7 days. Antibacterial behavior was determined by inoculating samples with 1 × 107 CFU/ml of Staphylococcus epidermidis (S. epi.) in a 1 × 108/ml brain heart infusion (BHI) agar culture for 24 h. After staining with PureBlu™ Hoechst 33342 or with DAPI and CFDA for SaOS-2 cell adhesion or bacterial presence, respectively, samples were examined with a confocal fluorescence microscope using a 488 nm Krypton/Argon laser source. Images were also acquired using a FEG-SEM in secondary and backscattered modes on gold sputter-coated specimens (∼20–30Å). Hydroxyapatite (HAp) deposition was measured using a laser microscope. Raman spectra were collected for samples in backscattering mode using a triple monochromator using a 532 nm excitation source (Nd:YVO4 diode-pumped solid-state laser).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 32 - 32
1 Jan 2016
McEntire B Bock R Rahaman M Bal BS Webster T Pezzotti G
Full Access

Silicon nitride spinal fusion cages have been successfully used in the treatment or correction of stenosis, disc herniation, trauma, and other deformities of the spinal column since 2008. To date over 14,000 devices have been implanted with perioperative and postoperative complication rates of less than 0.2%. This remarkable achievement is due in part to the material itself. Silicon nitride is an ideal interbody material, possessing high strength and fracture toughness, inherent phase stability, biocompatibility, hydrophilicity, excellent radiographic imaging, and bacterial resistance. These characteristics can lead to implants that aid in prevention of nosocomial infections and achieve rapid osteointegration. In this paper, we will review the various in vitro and in vivo studies that demonstrate silicon nitride's effective bacteriostatic and osteointegration characteristics, and compare these to the two most common cage materials – titanium and poly-ether-ether-ketone (PEEK). Human case studies will be also reviewed to contrast the clinical performance of these biomaterials. In comparison to the traditional devices, silicon nitride shows lower infection rates, higher bone apposition, and essentially no fibrous tissue growth on or around the implant. To better understand the mechanisms underlying these benefits, surface characterization studies using scanning electron microscopy coupled with XPS chemical analyses, sessile water drop techniques and streaming zeta potential measurements will be reported. Data from these studies will be discussed in relation to the physiochemical reasons for the observed behavior. Silicon nitride is a non-oxide ceramic in its bulk; but possesses a protective Si-N-O transitional layer at its surface. It will be shown that the chemistry and morphology of this layer can be modified in composition, thickness and structure resulting in marked changes in chemical species, surface charge, isoelectric points and wetting behavior. It is postulated that the needle-like grain structure of silicon nitride coupled with its enhanced wettability play important roles in inhibiting biofilm formation, while its surface chemical environment consisting of silicon diimide Si(NH)2, silicic acid Si(OH)4, and derivatives of ammonia, NH3, NH4OH, lead to improved bone reformation and bacteriostasis, respectively. Few materials have this combination of properties, making silicon nitride a unique biomaterial that provides improved patient care and outcomes with low comorbidities.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 34 - 34
1 Jan 2016
McEntire B Bal BS Lakshminarayanan A Bock R
Full Access

It has been seven years since silicon nitride (Si3N4) was first proposed as a new bearing material for total hip arthroplasty [1]. Although its introduction into this application has been hampered by regulatory and clinical hurdles, it remains a strong candidate for advancing the state of care in patients undergoing joint replacement. Si3N4 has a distinctive set of properties, such as high strength and fracture toughness, inherent phase stability, low wear, scratch resistance, biocompatibility, hydrophilicity, excellent radiographic imaging, and bacterial resistance, many of which are not fully realized with other bioceramics. This combination of properties is desirable for demanding structural implants in the hip, knee and other total joints. Of foremost concern to clinicians is the wear behavior of any new or novel bearing material. Minimization of wear debris and prevention of corresponding osteolytic lesions are essential regardless of whether the artificial implant is articulating against itself, a metallic or polymeric counterpart. In this regard, Si3N4 may have a unique advantage. Other bearing couples rely solely on the presence of a biologic lubricating film to minimize erosive wear. However, Si3N4 forms a tribochemical film between the articulation surfaces consisting of silicon diimide Si(NH)2, silicic acid Si(OH)4, and ammonia groups NH3, NH4OH. Depending upon the bearing couple, this tribochemical film generally produces low friction. It is self-replenishing and resorbable, leading to the minimization of wear debris within the joint capsule. In this paper, we will review the essential physical, mechanical, and surface chemistry of Si3N4, and contrast these properties with other available bioceramics. Results from hip simulator testing of Si3N4 femoral heads on conventional and highly cross-linked polyethylene will be presented and discussed. Data will demonstrate that various Si3N4 bearing couples have wear comparable to other bioceramics. Microscopy and spectroscopic examinations of surfaces will provide a view of the surface stoichiometry and chemical stability of Si3N4 in comparison to other bioceramics. Laboratory friction tests will be reported, which show that the tribochemistry of the lubricating film generated by Si3N4 favors the use of highly cross-linked polyethylene as a counterface material. Overall results will demonstrate that silicon nitride is poised to become a new generation biomaterial for total joint arthroplasty.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 86 - 86
1 Dec 2013
Bal BS Ivie C Davis M Crist B
Full Access

Introduction:

Patient-specific cutting guides (PSCG) built from imaging of the extremity can improve the accuracy of bone cuts during total knee replacement (TKR). Some reports have suggested that PSCG offer only marginal improvement in the accuracy of alignment and component positioning in TKA. We compared outcomes between TKRs done with PSCG versus standard, intramedullary-based instrumentation.

Methods:

Blood loss, duration of surgery, alignment of the mechanical axis of the leg, and implant position on standing, long-leg, and standard lateral digital radiographs were compared between a CT-guided, custom-built TKA implant (n = 50; ConforMIS iTotal, Boston, MA) implanted with PSCG, versus an off-shelf posterior stabilized TKA implanted with standard instrumentation (n = 50; NKII total knee, Zimmer, Warsaw, IN). The fraction of outliers (>3 degrees) was calculated for the two groups.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 129 - 129
1 Mar 2013
McEntire BJ Lakshminarayanan A Bal BS Webster T Ercan B Gorth D
Full Access

Objective

Superior bone ingrowth and resistance to bacterial infection are ideal for orthopaedic implants. We compared new bone formation, strength of bone bonding, and infection rates between silicon nitride ceramic (Si3N4; abbreviated SiN), medical-grade PEEK (PEEK), and titanium (Ti) in rat calvariae. PEEK and Ti are used in spinal and arthroplasty implants respectively, while SiN is a non-oxide ceramic used in spinal implants for the past 4 years.

Methods

Specimens of 10 mm × 10 mm by 1.75 mm size were implanted into experimental calvarial defects in 2-year old Wistar rats using standard surgical techniques (n's: SiN=48; PEEK=24; Ti=24). One group of animals was immediately inoculated with 1 × 104 Staphylococcus epidermidis; control animals received saline only. After sacrifice at 3 days, 7 days, 14 days, and 3 months post-inoculation (n=4 rats per time period), one calvarial sample each for PEEK and Ti, and two samples for SiN (per bacterial condition and time point) were retrieved for histology; remaining samples were used for sample push-out testing with a Micro Tester 5848 (Instron) with a 1-kN load cell, using published techniques. New bone formation was measured with tetracycline double-labeling at 11 and 4 days before the 14-day and 3-month time periods.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 8 - 8
1 Mar 2013
McEntire BJ Lakshminarayanan A Bal BS Webster T
Full Access

Oxide ceramics, such as alumina and zirconia have been used extensively in arthroplasty bearings to address bearing wear and mitigate its delayed, undesirable consequences. In contrast to oxide ceramics that are well-known to orthopaedic surgeons, silicon nitride (Si3N4) is a non-oxide ceramic that has been investigated extensively in very demanding industrial applications, such as precision bearings, cutting tools, turbo-machinery, and electronics. For the past four years, Si3N4 has also been used as a biomaterial in the human body; specifically in spinal fusion surgery. As a implantable biomaterial, Si3N4 has unique properties, such as high strength and fracture toughness, inherent chemical and phase stability, low wear, proven biocompatibility, excellent radiographic imaging, antibacterial advantages, and superior osteointegration. This property combination has proven beneficial and desirable in orthopaedic implants made for spinal fusion, spinal disc reconstruction, hip and knee arthroplasty, and other total joints (Fig. 1). The physical properties, shapes, sizes and surface features of Si3N4 can be engineered for each application – ranging from dense, finely polished articulation components, to highly porous scaffolds that promote osteointegration. Both porous and polished surfaces can be incorporated in the same implant, opening a number of opportunities for arthroplasty implant design. Crack propagation modes for in situ toughened Si3N4 differ favorably from those of conventional ceramics, rendering Si3N4 extremely resistant to catastrophic failure in vivo (Fig. 2). Most significantly, our recent work has shown that Si3N4 is resistant to bacterial biofilm formation, colonization and growth, when compared to medical-grade PEEK and titanium. These anti-infective characteristics are particularly valuable for in vivo implantation. We will present the unique properties and characteristics of Si3N4, and compare these to other ceramic and non-ceramic biomaterials. Si3N4 was once used only in industrial applications, but early data show that this novel biomaterial is positively impacting orthopaedic care and will continue to do so into the future.