header advert
Results 1 - 5 of 5
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1468 - 1474
1 Nov 2012
Hill JC Archbold HAP Diamond OJ Orr JF Jaramaz B Beverland DE

Restoration of leg length and offset is an important goal in total hip replacement. This paper reports a calliper-based technique to help achieve these goals by restoring the location of the centre of the femoral head. This was validated first by using a co-ordinate measuring machine to see how closely the calliper technique could record and restore the centre of the femoral head when simulating hip replacement on Sawbone femur, and secondly by using CT in patients undergoing hip replacement.

Results from the co-ordinate measuring machine showed that the centre of the femoral head was predicted by the calliper to within 4.3 mm for offset (mean 1.6 (95% confidence interval (CI) 0.4 to 2.8)) and 2.4 mm for vertical height (mean -0.6 (95% CI -1.4 to 0.2)). The CT scans showed that offset and vertical height were restored to within 8 mm (mean -1 (95% CI -2.1 to 0.6)) and -14 mm (mean 4 (95% CI 1.8 to 4.3)), respectively.

Accurate assessment and restoration of the centre of the femoral head is feasible with a calliper. It is quick, inexpensive, simple to use and can be applied to any design of femoral component.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 296 - 296
1 Jul 2008
Archbold HAP Mockford B Molloy D McConway J Ogonda L Beverland D
Full Access

Introduction: A critical determinant of early dislocation following total hip arthroplasty (THA) is correct positioning of the acetabular component. This challenging aspect of THA has not been lessened by the introduction of more minimally invasive techniques. In this paper we introduce a simple and reproducible technique, which uses the transverse acetabular ligament (TAL) to determine cup orientation. We have used this technique as the sole method of cup orientation in our last 1000 consecutive primary total hips.

Methods: One thousand consecutive patients were studied in order to determine the prevalence of early dislocation (within 3 months) following acetabular component placement determined by reference to the transverse ace-tabular ligament. All patients underwent primary total hip arthroplasty via a posterolateral approach with a posterior repair.

Results: At a minimum follow-up of 9 months (range 9–39 months) 6 of the 1000 hips (0.6%) had dislocated.

Conclusion: Although multiple factors are known to contribute to this rate correct placement of the acetabular component is critical. As our results compare favourably with other published series where a posterior repair has been performed by extrapolation we feel that that the TAL does provide an acceptable method of determining cup orientation. The fact that it is independent of patient position on the table and is easy to locate with a minimally invasive approach makes it an attractive method.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 320 - 320
1 Jul 2008
Molloy DO McConway J Archbold HAP Ogonda L Beverland MDE
Full Access

Patients and Methods: One hundred and fifty patients with pre-operative haemoglobin levels of 13.0g/dl or less were enrolled into a randomised controlled trial comparing the blood saving effect of intravenous tranexamic acid and topical fibrin spray on blood loss following primary total knee arthroplasty.

Those randomly assigned to the Tranexamic Acid group received 500mg intravenously five minutes prior to tourniquet deflation and a repeat dose three hours later. Those assigned to the Topical Fibrin Spray group received 10mls of the combined product intra-operatively. Those in the control group received no pharmacological intervention.

Results: There was a significant saving in total calculated blood loss for those in the topical fibrin spray group (p=0.016) and the tranexamic acid group (0.041) compared with the control group with losses of 1190mls, 1225mls and 1415mls respectively. The increased reduction in blood loss in the topical fibrin spray group was not significantly different to that in the tranexamic acid group (p=0.72).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 306 - 309
1 Mar 2007
Molloy DO Archbold HAP Ogonda L McConway J Wilson RK Beverland DE

We performed a randomised, controlled trial involving 150 patients with a pre-operative level of haemoglobin of 13.0 g/dl or less, to compare the effect of either topical fibrin spray or intravenous tranexamic acid on blood loss after total knee replacement.

A total of 50 patients in the topical fibrin spray group had 10 ml of the reconstituted product applied intra-operatively to the operation site. The 50 patients in the tranexamic acid group received 500 mg of tranexamic acid intravenously five minutes before deflation of the tourniquet and a repeat dose three hours later, and a control group of 50 patients received no pharmacological intervention.

There was a significant reduction in the total calculated blood loss for those in the topical fibrin spray group (p = 0.016) and tranexamic acid group (p = 0.041) compared with the control group, with mean losses of 1190 ml (708 to 2067), 1225 ml (580 to 2027), and 1415 ml (801 to 2319), respectively. The reduction in blood loss in the topical fibrin spray group was not significantly different from that achieved in the tranexamic acid group (p = 0.72).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 883 - 886
1 Jul 2006
Archbold HAP Mockford B Molloy D McConway J Ogonda L Beverland D

Ensuring the accuracy of the intra-operative orientation of the acetabular component during a total hip replacement can be difficult. In this paper we introduce a reproducible technique using the transverse acetabular ligament to determine the anteversion of the acetabular component. We have found that this ligament can be identified in virtually every hip undergoing primary surgery. We describe an intra-operative grading system for the appearance of the ligament. This technique has been used in 1000 consecutive cases. During a minimum follow-up of eight months the dislocation rate was 0.6%. This confirms our hypothesis that the transverse acetabular ligament can be used to determine the position of the acetabular component. The method has been used in both conventional and minimally-invasive approaches.