header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 1 - 1
1 Jul 2022
Clarke H Antonios J Bozic K Spangehl M Bingham J Schwartz A
Full Access

Abstract

Introduction

Periprosthetic joint infection (PJI) is a common cause of revision total knee surgery. Although debridement and implant retention (DAIR) has lower success rates in the chronic setting, it is an accepted treatment for acute PJI. There are two broad DAIR strategies: single debridement or a planned double debridement performed days apart. The purpose of this study is to evaluate the cost-effectiveness of single versus double DAIR with antibiotic beads for acute PJI in total knee arthroplasty (TKA).

Methodology

A decision tree using single or double DAIR as treatment strategies for acute PJI was constructed. Quality Adjusted Life Years (QALYs) and costs associated with the two treatment arms were calculated. Treatment success rates, failure rates, and mortality rates were derived from the literature. Medical costs were derived from both the literature and Medicare data. A cost-effectiveness plane was constructed from multiple Monte Carlo trials. A sensitivity analysis identified parameters most influencing the optimal strategy decision.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 42 - 42
1 Jul 2014
Goodman S Yao Z Ren P Gibon E Rao A Pajarinen J Antonios J Lin T Smith R Egashira K Keeney M Yang F Konttinen Y
Full Access

Summary

Wear particles from joint replacements may result in loosening and periprosthetic osteolysis. Interference with systemic macrophage trafficking to the implant, modulation of macrophage phenotype from M1 to M2, and inhibition of NFκB may mitigate these adverse effects.

Introduction

Joint replacement of the lower extremity is highly successful in alleviating pain, and improving ambulation and function. However, prosthetic byproducts of different materials, in sufficient amounts, may lead to loosening and periprosthetic osteolysis. Debris from polymers (such as polyethylene and PMMA), metals and ceramics are capable of inciting an adverse tissue reaction, which is orchestrated by cells of the monocyte/macrophage lineage. Three experimental approaches have been taken by our group to potentially mitigate the adverse biological sequela of particle disease. These include: 1) interfering with ongoing migration of monocyte/macrophages to the implant site by inhibiting the chemokine system 2) altering the functional activities of local macrophages by converting pro-inflammatory M1 macrophages to an anti-inflammatory pro-tissue healing M2 phenotype and 3) modulating the production and release of pro-inflammatory cytokines, chemokines and other potentially harmful factors by inhibiting the key transcription factor NFκB.