header advert
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 42 - 42
10 Feb 2023
Fary C Abshagen S Van Andel D Ren A Anderson M Klar B
Full Access

Advances in algorithms developed with sensor data from smart phones demonstrates the capacity to passively collect qualitative gait metrics. The purpose of this feasibility study was to assess the recovery of these metrics following joint reconstruction. A secondary data analysis of an ethics approved global, multicenter, prospective longitudinal study evaluating gait quality data before and after primary total knee arthroplasty (TKA, n=476), partial knee arthroplasty (PKA, n=139), and total hip arthroplasty (THA, n=395). A minimum 24 week follow-up was required (mean 45±12, range 24 - 78). Gait bouts and gait quality metrics (walking speed, step length, timing asymmetry, and double support percentage) were collected from a standardized smartphone operating system. Pre- and post-operative values were compared using paired-samples t-tests (p<0.05).

A total of 595 females and 415 males with a mean age of 61.9±9.3 years and mean BMI of 30.2±6.1 kg/m2 were reviewed. Walking speeds were lowest at post-operative week two (all, p<.001). Speeds exceeded pre-operative means consistently by week 21 (p=0.015) for PKA, and week 13 (p=0.007) for THA. The average weekly step length was lowest in post-operative week two (all, p<0.001). PKA and THA cases achieved pre-operative step lengths by week seven (p=0.064) and week 9 (p=0.081), respectively. The average weekly gait asymmetry peaked at week two post-operatively (all, p <0.001). Return to pre-operative baseline asymmetry was achieved by week 11 (p=0.371) for TKA, week six (p=0.541) for PKA, and week eight (p=.886) for THA. Double limb support percentages peaked at week two (all, p<0.001) and returned to pre-operative levels by week 24 (p=0.089) for TKA, week 12 (p=0.156) for PKA, and week 10 (p=0.143) for THA.

Monitoring gait quality in real-world settings following joint reconstruction using smartphones is feasible, and may provide the advantage of removing the Hawthorne effect related to typical gait assessments and in-clinic observations.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 14 - 14
1 Jun 2021
Anderson M Lonner J Van Andel D Ballard J
Full Access

Introduction

The purpose of this study was to demonstrate the feasibility of passively collecting objective data from a commercially available smartphone-based care management platform (sbCMP) and robotic assisted total knee arthroplasty (raTKA).

Methods

Secondary data analysis was performed using de-identified data from a commercial database that collected metrics from a sbCMP combined with intraoperative data collection from raTKA. Patients were included in this analysis if they underwent unilateral raTKA between July 2020 and February 2021, and were prescribed the sbCMP (n=131). The population consisted of 76 females and 55 males, with a mean age of 64 years (range, 43 – 81). Pre-operative through six-week post-operative data included step counts from the sbCMP, as well as administration of the KOOS JR. Intraoperative data included surgical times, the hip-knee-ankle angle (HKA), and medial and lateral laxity assessments from the robotic assessment. Data are presented using descriptive statistics. Comparisons were performed using a paired samples t-test, or Wilcoxon Signed-rank test, with significance assessed at p<0.05. A minimal detectable change (MDC) in the KOOS JR score was considered ½ standard deviation of the preoperative values.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 15 - 15
1 Jun 2021
Anderson M Van Andel D Israelite C Nelson C
Full Access

Introduction

The purpose of this study was to characterize the recovery of physical activity following knee arthroplasty by means of step counts and flight counts (flights of stairs) measured using a smartphone-based care platform.

Methods

This is a secondary data analysis on the treatment cohort of a multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total and unicondylar joint arthroplasty. Participants in the treatment arm that underwent primary total or unicondylar knee arthroplasty and had at least 3 months of follow-up were included (n=367). Participants were provided the app with an associated smart watch for measuring several different health measures including daily step and flight counts. These measures were monitored preoperatively, and the following postoperative intervals were selected for review: 2–4 days, 1 month, 1.5 month, 3 months and 6 months. The data are presented as mean, standard deviation, median, and interquartile range (IQR). Signed rank tests were used to assess the difference in average of daily step counts over time. As not all patients reported having multiple stairs at home, a separate analysis was also performed on average flights of stairs (n=214). A sub-study was performed to evaluate patients who returned to preoperative levels at 1.5 months (step count) and 3 months (flight count) using an independent samples T test or Fisher's Exact test was to compare demographics between patients that returned to preoperative levels and those that did not.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 13 - 13
1 Jun 2021
Anderson M Van Andel D Foran J Mance I Arnold E
Full Access

Introduction

Recent advances in algorithms developed with passively collected sensor data from smart phones and watches demonstrate new, objective, metrics with the capacity to show qualitative gait characteristics. The purpose of this feasibility study was to assess the recovery of gait quality following primary total hip and knee arthroplasty collected using a smartphone-based care platform.

Methods

A secondary data analysis of an IRB approved multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total knee arthroplasty (TKA, n=88), unicondylar knee arthroplasty (UKA, n=28), and total hip arthroplasty (THA, n=82). Subjects were followed from 6 weeks preoperative to 24 weeks postoperative. The group was comprised of 117 females and 81 males with a mean age of 61.4 and BMI of 30.7. Signals were collected from the participants' smartphones. These signals were used to estimate gait quality according to walking speed, step length, and timing asymmetry. Post-operative measures were compared to preoperative baseline levels using a Signed-Rank test (p<0.05).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 56 - 56
1 Oct 2020
Lombardi AV Berend KR Huddleston J Crawford D Peters C VanAndel D Anderson M DeHaan A Southgate R Duwelius PJ
Full Access

Background

The purpose of this study is to evaluate the early outcomes with the use of a smartphone-based exercise and educational platform after primary total hip arthroplasty compared to a standard of care control group.

Methods

A multicenter prospective randomized control trial was conducted evaluating the use of the mymobility smartphone-based care platform for primary total hip arthroplasty (THA). Patients randomized to the control group (198 patients) received the respective institution's standard of care. Those randomized to mymobility treatment group (167 patients) were provided an Apple Watch and mymobility smartphone application. The application provides pre and postoperative educational content, video directed exercise programs as well as tracks the patient's activity. Patients in the treatment group were not initially prescribed physical therapy, but could be if their surgeon deemed it necessary. Early outcomes assessed included 90-day hip range of motion, HOOS JR scores, 30-day single leg stance (SLS) and time up and go (TUG) test.

We also evaluated PT utilization, THA complications associated with readmissions, ER visits not associated with readmissions, urgent care (non standard of care) visits, and physician office visits.

Outcome scores include HOOS-Jr, EQ-5D-5L, single stance (SLS), Timed up and go (TUG).

Satisfaction scores for the procedure and the mymobility study group were also recorded.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 70 - 70
1 Oct 2018
Wodowski AJ Pelt CE Erickson J Anderson M Gililland J Peters CL Duensing I
Full Access

Introduction

Recent studies of novel healthcare episode payment models, such as the Bundled Payments for Care Improvement (BPCI) initiative, have demonstrated pathways for improving value. However, these models may not provide appropriate payments for patients with significant medical comorbidities or complications. The objective of this study was to identify risk factors for exceeding our institution's target payment, the so-called “bundle busters.”

Methods

After receiving an exemption from the Institutional Review Board, we queried our institutional data warehouse for all patients (n=412) that underwent total joint arthroplasty (TJA) of the hip (n=192), knee (n=207), or ankle (n=13), and qualified for our institution's bundled payments model during the study time period (July 2015 – May 2017). Patients with medical conditions that were not well controlled or were potentially optimizable were all sent for preoperative medical optimization prior to surgery. For each 90-day episode, patient characteristics, medical comorbidities, perioperative data, and payments from the Centers for Medicare and Medicaid Services (CMS) were obtained. Episodes where Medicare payments exceeded the target payment were considered “busters”. The busters were older, and had higher comorbidity scores (all, p<0.01). Variables were summarized using descriptive statistics and risk ratios were calculated using a modified Poisson regression analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 50 - 50
1 Jan 2018
Makarewich CA Christensen M Anderson M Gililland J Pelt C Peters C
Full Access

Total hip arthroplasty (THA) in the young patient has been associated with higher rates of revision and perioperative complications. For clinicians and patients alike, there remains a desire to better characterize the durability of THA in young patients. We reviewed secondary data from our institutional database for all patients who underwent primary THA from January 2000 to May 2015. Patients were identified using ICD-9 procedure code 81.51. Our primary interest was the survival of implants in patients 30 years of age or younger (n=167) while using a contemporaneous cohort of patients age 60 and older as a control (n=1359). Failure was defined as revision THA for any reason. Cox regression with robust standard errors was used to calculate hazard ratios. A population-averaged Poisson regression analysis was used to compare complication rates.

The rate of all-cause revision THA was 2.4 times greater (95% CI 1.10 – 5.37, p=0.028) in young patients (7%, 12/167) undergoing primary or conversion to THA compared to their elderly counterparts (3.7%, 50/1,359). Survival at 10 years was 89% (95% CI 82 – 94) in the young cohort and 96% (94 – 97) in the elderly cohort. The primary reasons for revision in young that patients compared to their elderly counterparts included metal-on-metal implants (IRR 8.12, 95% CI 2.04 – 32.38, p=0.003).

These data demonstrate that patients 30 years of age and younger substantially benefit from THA but should be warned of higher risk of subsequent revision.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 419 - 419
1 Nov 2011
Heuer D Williams M Moss R Butcher K Anderson M Milner R Alley C Gilmour L Scott M
Full Access

This study evaluated the biologic fixation of two different titanium porous coatings: a clinically successful sintered spherical bead coating [1] and a new sintered asymmetric particle coating (STIKTITE™, Smith & Nephew). The spherical bead coating has a porosity of about 50% and an average pore size of about 220 μm, whereas the STIKTITE coating has greater porosity (about 62%) and slightly smaller average pore size (about 200 μm). Biologic fixation was assessed using a load-bearing ovine model in which coated semi-circular disc implants were inserted into a defect created in the cancellous bone parallel to and approximately 3 mm below the medial tibial plateau [2] similar to the method reported by Ignatius [3]. The implants were slightly thicker than the defect created, producing a 0.2-mm overall pressfit. Initial implant stability was assessed using mechanical push-out (n = 3) immediately after implantation into cadaveric ovine bone. Quantitative mechanical push-out testing and qualitative histology (n = 9 and n = 2, respectively, per group per time point) was performed after six and 26 weeks in vivo.

The time-zero average peak push-out load (±S.D.) of the STIKTITE group (95±3 N) was found to be significantly greater (p < 0.02) than that of the spherical bead group (36±5 N). By six weeks in vivo, the average peak push-out load for the STIKTITE group was up to 1001±362 N, and that for the spherical bead group was up to 985±425 N, both representing a significant increase compared to their time-zero results (p < 0.0005). From six to twenty-six weeks in vivo, there was again a significant increase in the peak push-out load irrespective of group (p < 0.0005), with the average peak push-out loads up to 1620±406 N and 1444±446 N for the STIK-TITE and spherical bead groups, respectively. Histology revealed bone ingrowth in both groups that confirmed the findings of the mechanical push-out testing. While the STIKTITE group showed a trend toward greater biologic fixation, overall there was insufficient evidence to support differences between the two groups (p = 0.47) irrespective of the amount of time in vivo.

The results of this study confirm the ability of the STIK-TITE coating to achieve superior initial stability. This improved initial stability reduces the reliance on adjunct fixation (such as screws) or large amounts of press-fit to prevent micromotion and create an environment suitable for long-term bone ingrowth. The results also suggest that the STIKTITE coating had a tendency to initiate and maintain bone ingrowth under load-bearing conditions to a level greater than that of a clinically successful sintered bead coating. Because loading of the implant can cause micromotion at the bone/implant interface, models like the one used in this study likely provide a more challenging and realistic representation of anticipated clinical conditions than models with minimal implant loading.