Vol. 91-B, Issue SUPP_II | Pages 268 - 268
1 May 2009
Biasibetti A Aloj D Di Gregorio G Salomone C Massè A
Full Access

Aims: Clinical use of BMP-7: actual situation The tibial pseudoarthrosis. The Friedlander paper can be considered the only golden standard about the clinical application. It is a prospective, randomized clinical trial comparing BMP-7 with fresh bone autograft. The results of the BMP-7 are similar under to use of fresh bone autograft. Some cases of very serious pseudoar-throsis treated with BMP-7 have demonstrated an high percentual of clinical recovery. In UOA of traumatology and in I Orthopaedic Clinic of Turin University the pseudoarthrosis are treated with the Ilizarov’s technique, not with the autologous transplantation, so Friedlander’s results are not discriminant for the our work.

Methods: In our department the guide lines for BMP-7 application are:

Delayed union of the docking point in pseudoarthrosis of long bones treated with the Ilizarov technique (resection and distractional osteogenesis) and traditional techniques (decortication and fresh bone autograft) not suitable for application. The treatment of a pseudoartrhosis is based on our classification in type: I, II, III, IV (septic).

Traditional techniques failure.

Choice first treatment in very difficult cases of limb reconstruction and bone nonunion.

Results: From 30/09/2002 till 28/02/2007 55 patients have been treated with BMP-7. In 5 cases it has been associated with autologus bone graft. The material is: 24 cases of traditional techniques failure, 17 cases in wich traditional techniques were unfeasible to be treated and 9 docking point nonunions, in 5 particular cases. Mean age is 38 years. Before last intervention, mean number of porevious operation is 6,5 with mean time before BMP procedures is 3 years. 43 patients healed, 9 are under treatment and 3 are failure. The mean time of healing was 4 months.

Conclusions: The series is strictly observational but results are effective in front of the complexity of cases. Late complications suggest that BMP-7 induces bone formation but mechanical function could need time to be achived.According to literature the BMP-7 should be usefull also in more simple cases but more prospective clinical double blind randomised series and cost decreasing are necessary to extend the indications for BMP-7 application.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 131 - 131
1 Mar 2009
Aprato A Garazzino S Biasibetti A Aloj D Di Perri G Masse’ A
Full Access

Antibiotic concentration in infected bone is a major determinant of clinical response. As glycopeptides and fluoroquinolones are widely used for the treatment of bone infections, aim of our study was to assess their diffusion in infected human bone. Patients with a posttraumatic septic pseudoarthrosis undergoing debridement of infected tissue, who received a glycopeptide or a fluoroquinolone for > 1 week, were studied. Plasma and bone specimens were collected intraoperatively for phamacokinetic and microbiologic assays at a mean of 4.1h after antibiotic administration. Bone samples were crushed and concentrations were measured by HPLC-UV method. Overall plasma exposure was also determined with daily sampling. 16 patients were studied. 6 patients received iv vancomycin 1 g bid over a 1-hr infusion Bone cultures grew E. faecalis, MRSA and MRSE (MIC < 2 mg/L). Mean plasma concentration of vancomycin at time of osteotomy was 19.8 mg/L. Mean bone concentrations were 2.4 mg/L in cortical and 7.1 mg/L in cancellous bone, with a mean bone extraction of 12 % and 36 %, respectively. 4 patients were treated with iv teicoplanin 10/mg/Kg for MRSA infection (MIC < 2 mg/L). Mean bone concentrations were 8.9 mg/L and 37 mg/l respectively for cortical and cancellous bone, respectively corresponding to 6% and 25% of plasma levels. Six patients were treated with a fluoroquinolone. 3 patients received iv ciprofloxacin 400mg bid and E. coli grew from bone samples(MIC = 0.5 mg/L). Mean Plasma concentration of ciprofloxacin at the time of osteotomy was 3.6 mcg/mL. Mean bone concentrations were 1.7 mg/L in cortical bone and 30.2 mg/L in cancellous and newly formed bone, with respective bone/ plasma ratios of 0.5 and 8.4. 3 patients were administered iv levofloxacin 500mg qd and Enterobacter spp. were isolated (MIC = 1 mg/L). Mean plasma concentration at the time of surgery was 2.5 mcg/mL. Mean bone concentrations were 0.3 and 2.69 mcg/mL in cortical and cancellous bone, respectively. To our knowledge this is the first study that compares different antibiotic’s concentration in infected bone with the same dosing procedure. Both vancomycin and teicoplanin provided mean bone concentrations exceeding the susceptibility breakpoint of the infecting agents. Higher and constant glycopeptides plasma levels may be required for preventing recurrencies in bone infections. Only ciprofloxacin provided cortical bone concentrations higher than the susceptibility breakpoint of the infecting agent, and similar to those reported in non-infected bone. Ciprofloxacin concentration in cancellous bone and in bony callus were far higher than those detected in plasma, which may be related to an augmented vascularization and/or selective accumulation of fluoroquinolones into regenerating bone, as observed in children’s cartilage growth plate. Ciprofloxacin may be therefore preferred to levofloxacin.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 109 - 109
1 Jul 2002
Biasibetti A Aloj D Gallinaro P
Full Access

The choice of treatment for open fractures is conditioned by the care of bone and soft tissue. Grade I open fractures can be treated as closed fractures, according to the centre’s protocol. In Grade II open fractures skin wounds must be left open, and the suture should be delayed for at least a week. Most authors perform fixation by means of intramedullary nails.

In our opinion, external fixation is the best choice in these cases. The skin cannot be closed in Grade III open fractures, and the basic point of treatment is adequate surgical debridement. The fixation must be done by external fixation. To achieve the treatment in an emergency situation, the device to be used must be quick and simple like a monolateral device that can be changed into a more complex one, such as an Ilizarov.

The Ilizarov technique uses distractional osteogenesis that can fill bone and soft tissue loss without further bone or soft tissue grafting.

Following these general guidelines, each district has its own particular approach to treating open fractures. Internal fixation by DCP plates is always indicated for forearm fractures. For a humerus fracture, simple direct shortening and external fixation can fill bone loss. Patients with fractures of the femur usually have multiple injuries. The problem is to provide a quick fixation in order to allow for easier intensive care. External fixation is the most indicated technique.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 118 - 118
1 Jul 2002
Biasibetti A Aloj D Gallinaro P
Full Access

The choice of treatment for open fractures is conditioned by the care of bone and soft tissue. Grade I open fractures can be treated as closed fractures, according to the centre’s protocol. In Grade II open fractures skin wounds must be left open, and the suture should be delayed for at least a week. Most authors perform fixation by means of intramedullary nails.

In our opinion, external fixation is the best choice in these cases. The skin cannot be closed in Grade III open fractures, and the basic point of treatment is adequate surgical debridement. The fixation must be done by external fixation. To achieve the treatment in an emergency situation, the device to be used must be quick and simple like a monolateral device that can be changed into a more complex one, such as an Ilizarov.

The Ilizarov technique uses distractional osteogenesis that can fill bone and soft tissue loss without further bone or soft tissue grafting.

Following these general guidelines, each district has its own particular approach to treating open fractures. Internal fixation by DCP plates is always indicated for forearm fractures. For a humerus fracture, simple direct shortening and external fixation can fill bone loss. Patients with fractures of the femur usually have multiple injuries. The problem is to provide a quick fixation in order to allow for easier intensive care. External fixation is the most indicated technique.