header advert
Results 1 - 20 of 23
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1162 - 1167
1 Sep 2018
Metcalfe AJ Ahearn N Hassaballa MA Parsons N Ackroyd CE Murray JR Robinson JR Eldridge JD Porteous AJ

Aims

This study reports on the medium- to long-term implant survivorship and patient-reported outcomes for the Avon patellofemoral joint (PFJ) arthroplasty.

Patients and Methods

A total of 558 Avon PFJ arthroplasties in 431 patients, with minimum two-year follow-up, were identified from a prospective database. Patient-reported outcomes and implant survivorship were analyzed, with follow-up of up to 18 years.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1282 - 1282
1 Sep 2014
Ackroyd CE Leslie ID


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 478 - 485
1 Apr 2013
Naveed MA Ackroyd CE Porteous AJ

We present the ten- to 15-year follow-up of 31 patients (34 knees), who underwent an Elmslie-Trillat tibial tubercle osteotomy for chronic, severe patellar instability, unresponsive to non-operative treatment. The mean age of the patients at the time of surgery was 31 years (18 to 46) and they were reviewed post-operatively, at four years (2 to 8) and then at 12 years (10 to 15). All patients had pre-operative knee radiographs and Cox and Insall knee scores. Superolateral portal arthroscopy was performed per-operatively to document chondral damage and after the osteotomy to assess the stability of the patellofemoral joint. A total of 28 knees (82%) had a varying degree of damage to the articular surface. At final follow-up 25 patients (28 knees) were available for review and underwent clinical examination, radiographs of the knee, and Cox and Insall scoring. Six patients who had no arthroscopic chondral abnormality showed no or only early signs of osteoarthritis on final radiographs; while 12 patients with lower grade chondral damage (grade 1 to 2) showed early to moderate signs of osteoarthritis and six out of ten knees with higher grade chondral damage (grade 3 to 4) showed marked evidence of osteoarthritis; four of these had undergone a knee replacement. In the 22 patients (24 knees) with complete follow-up, 19 knees (79.2%) were reported to have a good or excellent outcome at four years, while 15 knees (62.5%) were reported to have the same at long-term follow-up. The functional and radiological results show that the extent of pre-operatively sustained chondral damage is directly related to the subsequent development of patellofemoral osteoarthritis.

Cite this article: Bone Joint J 2013;95-B:478–85.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 575 - 575
1 Aug 2008
Porteous AJ Mulford JS Newman JH Ackroyd CE
Full Access

Purpose: Revision patellofemoral arthroplasty (PFA) is a relatively uncommon procedure, with no published reviews identified in the literature. Revision PFAs performed at our institution were reviewed to determine the reasons for PFA failure, the technical ease of revision and to document patient-reported outcomes after revision.

Methods: A prospective review of a cohort of 411 Avon PFA patients identified 31 subsequent revision knee procedures in 27 patients. Data was collected from the institution’s prospective data base, operative reports, X-rays and medical records. Post-operative knee scores (Oxford Knee Score, WOMAC Osteoarthritis Index, Bristol Knee Score) were available on 26 knees.

Results: The commonest reason for revision was progression of osteoarthritis (18 cases) followed by undetermined pain (7 cases). Patients with undetermined pain were found to be revised sooner than patients with disease progression (33 months vs 63 months) and also reported poorer outcome scores at 2 years post revision than the disease progression group.

Only two trochlea components were loose at the time of revision and one patella had a large amount of macroscopic wear. All other components were found to be well fixed with minimal wear at the time of revision. There were no difficulties in removing either component. No cases required augments or stemmed femoral components due to bone loss.

Patients undergoing revision surgery did report improvement in their post revision outcome scores compared with their pre-operative scores. The average Oxford Knee Score improved from 17 to 23, Bristol Knee Pain Scores improved from 11 to 20 and Bristol Knee Functional Scores improved from 15 to 16. These results are poorer than those recorded by the overall cohort of primary PFA.

Conclusion: PFA is easy to revise to a primary total knee. Results of revision knees are improved from pre-operative scores but not as good as expected.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 324 - 325
1 Jul 2008
Ackroyd CE Newman JH Evans R Joslin CC
Full Access

Objective: To review the results of the Avon patellofemoral arthroplasty at 5 to 8 years.

Methods: The Avon patellofemoral arthroplasty was introduced in clinical practice in September 1996. We present a prospective cohort review of all patients treated in the first three years. Patients were evaluated using the Bristol knee score (BSK), the Melbourne patella score (MPS) and the Oxford knee score (OKS).

Results: 109 patellofemoral arthroplasties were performed in 92 patients between September 1996 and November 1999. The median age was 68 years (range 46 to 86 years). Nine patients (12 knees) died and two patients (two knees) were unfit for follow-up. Ten knees in 9 patients were lost to follow-up giving a follow-up rate of 89%. The mean period of follow-up was 5.6 years.

The median pain score rose from 15/40 pre-operatively to 40 points at eight years. The median (MPS) rose from 10/30 points pre-operatively to 25 points at eight years. The median (OKS) rose from 18/48 pre-operatively to 38 at eight years. 87% of knees had mild or no pain at eight years. There were no cases of failure of the prosthesis itself. All 15 revisions resulted from progression of arthrititis in the tibio-femoral joint. The five-year survival rate for all causes with 86 cases at risk was 96%.

Conclusions: The results show that this type of arthroplasty can give predictable pain relief and excellent functional improvement in patients with isolated patello-femoral arthritis. Disease progression is the main reason for revision to total knee replacement and great care is required in assessing the indications for this procedure.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 324 - 324
1 Jul 2008
Steele RG Newman JH Hutabarat S Evans R Ackroyd CE
Full Access

Purpose of Study: Fixed bearing unicompartmental knee replacement (UKR) has become popular since several series have shown good 10 year survivorship and excellent function. However little is known about survival during the second decade.

Method: From the Bristol database of over 4000 knee replacements 203 St. George Sled UKR’s which had already survived 10 years were identified. The mean age at surgery was 67 years (48–85), with 64% being female. This cohort has been further reviewed at an average of 14.8 years (10–30) from surgery to determine survivor-ship and function.

Results: Survivorship during the second decade was 87.5%. 58 patients (69 knees) had deceased with implant in situ, only 2 after revision. A further 15 UKR’s have been revised at an average of 13 years post op; 7 for progression of disease, 4 for tibial loosening, 3 for polyethylene wear, 2 for femoral component fracture and 2 for infection.

99 knees were followed for 15 years and 21 knees for 20 years. The average Bristol knee score of the surviving knees fell from 86 to 79 during the second decade.

A previous study showed an 89% 10 year survivor-ship and this is now extended to 82% at 15 years and 76.5% at 20 years.

Conclusion: Satisfactory survival of fixed bearing UKR can be achieved in the second decade suggesting that the indications for mobile bearings require careful definition since there is a higher incidence of complications in many people’s hands.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 310 - 315
1 Mar 2007
Ackroyd CE Newman JH Evans R Eldridge JDJ Joslin CC

We report the mid-term results of a new patellofemoral arthroplasty for established isolated patellofemoral arthritis. We have reviewed the experience of 109 consecutive patellofemoral resurfacing arthroplasties in 85 patients who were followed up for at least five years.

The five-year survival rate, with revision as the endpoint, was 95.8% (95% confidence interval 91.8% to 99.8%). There were no cases of loosening of the prosthesis. At five years the median Bristol pain score improved from 15 of 40 points (interquartile range 5 to 20) pre-operatively, to 35 (interquartile range 20 to 40), the median Melbourne score from 10 of 30 points (interquartile range 6 to 15) to 25 (interquartile range 20 to 29), and the median Oxford score from 18 of 48 points (interquartile range 13 to 24) to 39 (interquartile range 24 to 45). Successful results, judged on a Bristol pain score of at least 20 at five years, occurred in 80% (66) of knees. The main complication was radiological progression of arthritis, which occurred in 25 patients (28%) and emphasises the importance of the careful selection of patients. These results give increased confidence in the use of patellofemoral arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1164 - 1168
1 Sep 2006
Steele RG Hutabarat S Evans RL Ackroyd CE Newman JH

There have been several reports of good survivorship and excellent function at ten years with fixed-bearing unicompartmental knee replacement. However, little is known about survival beyond ten years.

From the Bristol database of over 4000 knee replacements, we identified 203 St Georg Sled unicompartmental knee replacements (174 patients) which had already survived ten years. The mean age of the patients at surgery was 67.1 years (35.7 to 85) with 67 (38.5%) being under 65 years at the time of surgery. They were reviewed at a mean of 14.8 years (10 to 29.4) from surgery to determine survivorship and function. There were 99 knees followed up for 15 years, 21 for 20 years and four for 25 years. The remainder failed, were withdrawn, or the patient had died.

In 58 patients (69 knees) the implant was in situ at the time of death. Revision was undertaken in 16 knees (7.9%) at a mean of 13 years (10.2 to 21.6) after operation. In seven knees (3.4%) this was for progression of arthritis, in three (1.5%) for wear of polyethylene, in four (2%) for tibial loosening, in two (1%) for fracture of the femoral component and in two (1%) for infection. Two knees (1%) were revised for more than one reason.

The mean Bristol knee score of the surviving knees fell from 86 (34 to 100) to 79 (42 to 100) during the second decade. Survivorship to 20 years was 85.9% (95% CI 82.9% to 88.9%) and at 25 years was 80% (95% CI 70.2% to 89.8%). Satisfactory survival of a fixed-bearing unicompartmental knee replacement can be achieved into the second decade and beyond.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 251 - 252
1 May 2006
Hendrix MRG Ackroyd CE
Full Access

Aims: determine functional outcome of revision Avon patellofemoral replacements (PFR), converted from primary Lubinus PFR.

Materials and Methods:

Prospective review of 11 knees (8 patients, 6 female).

Average age at primary PFR – 64 years

Indication – isolated patellofemoral osteoarthritis (11), patellofemoral instability (3)

9 knees (7 patients) temporarily improved.

Revision Avon PFR at average 83 months after primary procedure.

Indication – polyethylene wear

polyethylene synovitis

femoral component malposition

At review:

average 61 months after revision

age – 70 years 10 months.

fixed flexion contracture 1.7°

maximum flexion 111°.

Bristol knee score improved from average of 54.5 to 77.2. Pain score component averaged 25, functional component averaged 16.9. No malalignment or instability.

Average American Knee Society Score 132.8

Bartlett patellar score 19.8

Three patients (4 knees) had medical problems contributing to their functional incapacity.

No radiological complications except minor polyethylene wear on lateral facet of one patella. Progression to tibiofemoral osteoarthritis (Ahlburgh grade 1) in 3 knees.

Discussion: Primary Lubinus PFR temporarily improved 82% of knees. Maltracking/polyethylene wear was usual cause for failure. Revision to Avon PFR resulted in substantial improvement of pain and function.

Conclusion: revision Avon PFR can provide a suitable alternative to revision to total knee replacement.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 441 - 441
1 Apr 2004
Ackroyd CE Newman JH Bedi G
Full Access

Purpose A new design of patello-femoral arthroplasty has been used to treat patients under 55 years suffering severe symptoms from chondral and early arthritic disease of the patello-femoral joint.

Materials and Methods and Results Fifty-two patello-femoral arthroplasties were performed in 45 patients under the age of fifty-five years when other treatments had failed. The average age was 48 years (range 36–54 years). Thirty-seven cases had undergone previous surgery for a variety of conditions, and the causes of the disorders were analysed. Results were assessed using pain scores and Bartlett’s and Oxford functional scores. 35 cases were reviewed at 8 months and 22 cases at two years. The median pain score improved from 10/40 points to 35 at two years. The Bartlett score increased from 10/30 points to 27 and the Oxford score from 19/48 points to 35 at two years. The range of movement increased from 114° to 121°. There have been no cases of deep infection, loosening, wear or instability. Disease progression, a potential risk has occurred in one case.

Conclusions This prosthesis offers a solution in younger patients with disabling symptoms of isolated early patello-femoral disease who have not responded to conservative surgical management.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 937 - 942
1 Sep 2003
Ackroyd CE


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 132 - 133
1 Feb 2003
Ackroyd CE Newman JH Elderidge J Webb J
Full Access

Isolated patellofemoral arthritis occurs in up to 10% of patients suffering osteoarthritis of the knee. Previous reports of several different patellofemoral designs have given indifferent results. The Lubinus prosthesis has been shown to have a 50% failure rate at eight years in a study of 76 cases. The main reasons for failure were mal-alignment, wear, impingement and disease progression. As a result of these studies, a new prosthesis was designed to solve some of these problems.

The Avon patellofemoral arthroplasty was first implanted in September 1996. The cases have been entered into a prospective review with evaluations at eight months, two years and five years. The outcome was assessed using pain scores, Bartlett’s patella score and the Oxford knee score. To date, 186 knees have been treated; over 100 knees have been reviewed at two years and 20 knees at five years. The main pain score improved from a pre-operative level of 13.5 points out of 40 to 33.5 points at two years and 36 at five years. The mean pre-operative movement was 109° and this increased to 120° at five years. The Bartlett patella score improved from a pre-operative level of 10.5 points out of 30 pre-operatively to 23 points at two years and 25 at five years. The Oxford knee score was 20 points out of 48 pre-operatively and this improved to 35 points at two years and 40 points at five years. One patient developed subluxation, which required distal soft tissue realignment. No other patient has developed problems with alignment or wear. Ten knees have developed evidence of disease progression usually in the medial compartment of which six have required revision to a total knee replacement.

The results to date suggest that this improved design has all but eliminated the previous problems of malalignment and early wear. The functional results are as good or better than those of a total knee replacement. There is a low complication rate and an excellent range of movement. Disease progression remains a potential problem. This type of prosthesis offers a reasonable alternative to total knee replacement in this small group of patients with isolated, early patellofemoral disease.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 53 - 53
1 Jan 2003
Ackroyd CE Newman JH
Full Access

The aim of this study was to report our experience of patellofemoral arthroplasty in isolated osteoarthrosis.

Material and Methods: The Lubinus Patellofemoral Arthroplasty was performed between 1989 and 1995 in 76 knees. The Avon Patella Femoral Arthroplasty was used from 1996 to 2001 in 187 knees. The average age of the patients was 65.5 years (range 36–87) with a male to female ratio of 1: 5. All the patients have been prospectively reviewed with standard radiographs, the Bristol Knee Score, and more recently Bartlett and Oxford scores.

Results: Patients with the Lubinus prosthesis were followed for an average of 7.4 years (range 5–10 years). Eleven patients (14 knees) have died and the remaining 62 knees have a 100% follow-up. The cumulative revision rate was 28% (21 out of 76). Survivorship at 8 years was 65% (Cl 49 to 77) for revision and 48% (Cl 36 to 59) for revision plus moderate pain. The two main complications were Maltracking 32% and progressive tibio-femoral arthritis in 9%.

The Avon Arthroplasty with improved design features for better tracking and congruity was introduced in 1996 and 187 have now been inserted in 147 patients. One hundred and nine knees have been followed for 8 months and 82 have completed the 2 year follow-up. Two patients have undergone revision to a TKR 97.5% (survivorship 2 out of 82). Three patients have had a unicompartmental arthroplasty added for disease progression. There have been no cases of patella maltracking or subliaxation.

Four year survivorship for moderate pain and revision is 96% (79 out of 82). Functional scores compared favourably with parallel series of total knee replacements.

Conclusion: The medium-term results of the Lubinus Patello Femoral Arthroplasty are unsatisfactory. We suggest the use of this prosthesis should be discontinued. The Avon Arthroplasty has improved results in the short-term.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 52 - 52
1 Jan 2003
Porteous AJ Ackroyd CE
Full Access

The aim of this study was to assess the value of plain AP and lateral radiographs in determining ACL condition in medial unicompartmental osteoarthritis.

Background: A functioning ACL has been shown to be important in the success of certain unicompartmental knee replacements. White (2001) has shown MRI to be too sensitive in this age group of patients. Keyes (1992) suggested that stress radiographs were necessary to accurately assess ACL integrity.

Method: One hundred and twenty-six patients undergoing knee arthroplasty for medial osteoarthritis, had their ACL’s graded as Normal, Frayed or Absent intra-operatively. Standard pre-operative AP and lateral standing radiographs were graded by the Ahlback system. On the lateral view, the plateau was divided into 5 zones from anterior to posterior. The zone, in which the point of deepest wear occurred, was recorded.

Results: There was a significant difference between the occurrence of deepest wear in the anterior three zones versus the posterior two zones for ACL normal and absent knees (2 = 46.85, P< 0.001). There was a significant difference between the occurrence of normal and absent ACL’s in Ahlback grades ≤3 versus ≥4 (2 = 53.8, P< 0.001). There was a moderately strong correlation between both zone of deepest wear on lateral radiograph and Ahlback grade with ACL condition (Spearman’s rho = 0.62 and 0.69 respectively). The Positive Predictive Values for the ACL being normal are 64% for Ahlback grades 3 or less and 67% for Zone of deepest wear in the anterior 3 zones. The Positive Predictive Values for the ACL being intact (but not necessarily normal) are 95% for Ahlback grade 3 or less; 91% for Zone of deepest wear in the anterior 3 zones; and 97% if these criteria are combined.

Combining Ahlback grade ≤3 with wear in the anterior 3 zones also gave a Negative Predictive Value of 92% for the ACL not being normal.

Conclusion: There is a “watershed” in ACL condition between Ahlback grade 3 and 4. Prostheses requiring Normal or Intact ACL’s should only be performed if Ahlback grade is ≤3. Standard radiographs can reliably predict ACL condition with high Positive and Negative predictive values.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 53 - 53
1 Jan 2003
Porteous AJ Ackroyd CE
Full Access

The aim of this study was to assess the distribution of wear down to bone in lateral compartment osteoarthritis and to analyse the effect of ACL condition and Ahlbach grading on this distribution.

Background: The distribution of medial compartment wear is now well described and shows posterior progression and increased area of wear with worsening AhIback grade and ACL condition (Porteous 2000). Harman (1998) described wear situated more posteriorly in the lateral compartment but did not show any change to this with altering ACL function, and did not assess the severity of the arthritis.

Method: Forty two tibial plateaus resected at total or unicompartmental replacement for lateral compartment osteoarthritis were analysed for the anterior and posterior extent of wear, as well as the point of deepest wear and the size of lesion. The plateau was divided into five zones from anterior to posterior. The ACL condition at surgery was graded as Normal, Frayed or Absent. Radiographs were classified by Ahlbach grade. Analysis using Mann-Whitney U-test, Fisher’s exact test and Spearman’s rank correlation were performed.

Results: The significant changes with increasing Ahlbach grade were that: the point of deepest wear moved posteriorly, the posterior extent of wear moved posteriorly and the size of the lesion increased. With ACL deterioration and rupture, the anterior extent of the wear moved forward and the size of lesion increased, but this did not occur through posterior migration of the posterior extent of the wear. There was a significant difference between the Ahlbach grade of ACL Normal and Absent knees.

Conclusion: In early disease, the wear is situated more posteriorly than in medial disease. The wear size increases with ACL insufficiency, but the further posterior progression of wear associated with posterior femoral subluxation seen in advanced disease seems to be more dependant on the loss of bone reflected in the Ahlbach grading.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 321 - 321
1 Nov 2002
Ashraf T Evans R Newman JH Ackroyd CE
Full Access

Objective: To report the survivorship rate and clinical outcome of a large series of lateral unicompartmental replacements.

Method: 88 lateral St Georg Sled LTKRS were performed between 1978 and 1999. Clinical and radiological data was prospectively recorded at regular follow up and only 5 knees were lost during the 22 year period.

Results: 15 knees were revised after an average of 8 years. (eight for progressive arthritis, six for loosening and four for femoral fracture) 29 patients (30 knees) died during the course of the study. At final follow up (average 9 years) 50 of the 63 remaining knees were rated as good or excellent, nine as fair and nine poor. The mean range of flexion was 110°.

At 10 years the cumulative survival rate was 83% and at 15 years 78% (10 knees at risk). The “worst case scenario” where knees with pain or lost to follow up are added to revisions shows a 10 year survivorship of 74%.

Conclusion: Although the results are not as good as medial UKR. These clinical outcomes suggest that the conservative surgical procedure of lateral UKR with the fixed bearing St George Sled prosthesis can give acceptable results in the uncommon situation of severely symptomatic isolated lateral tibio femoral arthritis.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 318 - 318
1 Nov 2002
Ackroyd CE Whitehouse SL Newman JH Joslin CC
Full Access

Purpose: To compare the ten-year survivorship results of an established total and medial compartment knee replacement performed in a single centre over an eighteen year period.

Method: Since 1978 knee replacements have been prospectively recorded in Bristol on a database. Regular clinical and radiological review has been undertaken every two or three years up to twenty years. 408 medial St Georg Unicompartmental replacements and 531 Kinematic total knee replacements have been subject to survivorship analysis using three failure end points. One - revision or removal of the implant. Two – revision or removal and moderate or severe pain. Three – the worst case including all patients lost to follow-up.

Results: The follow-up rate was 97% in both groups. 212 patients (562 knees) died and 31 patients (35 knees) were lost to follow-up. At ten years 25 medial Sled and 20 Kinematic knee arthroplasties had been revised. There was no significant difference (p > 0.05) in the number of good and excellent results. The mean range of movement at the last follow-up was 109 degrees for the medial Sled and 100 degrees for the Kinematic (p< 0.01). 94% of the medial Sled patients obtained a range of movement equal to or greater than 90 degrees whereas only 84% of Kinematic patients obtained this range (p < 0.05).

The ten-year survivorship figures were similar for both groups. Revision as the end point was 87.5% for the medial Sled and 89.6% for the Kinematic knees. When moderate and severe pain was considered in addition to revision ten-year survivorship was 79.4% in both groups. The worst case survivorship was also 74% in both groups.

Conclusion: The ten-year survivorship results of a fixed bearing, non-congruous, Unicompartmental arthroplasty are as good as those of a total knee replacement when performed in a single centre by two consultant surgeons and a variety of trainees. The advantages of a more rapid recovery and better quality result are offset by an easier though slightly higher revision rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1126 - 1130
1 Nov 2002
Ashraf T Newman JH Evans RL Ackroyd CE

We describe 88 knees (79 patients) with lateral unicompartmental osteoarthritis which had been treated by the St Georg Sled prosthesis.

At a mean follow-up of nine years (2 to 21) 15 knees had revision surgery, nine for progression of arthritis, six for loosening, four for breakage of a component and four for more than one reason. Six patients complained of moderate or severe pain at the final follow-up. Only five knees were lost to follow-up in the 21-year period.

We performed survivorship analysis on the group using revision for any cause as the endpoint. At ten years the cumulative survival rate was 83%, and at 15 years, when ten knees were still at risk, it was 74%.

Based on our clinical results and survival rate the St Georg Sled may be considered to be a suitable unicompartmental replacement for isolated lateral compartment osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 667 - 672
1 Jul 2002
Ackroyd CE Whitehouse SL Newman JH Joslin CC

We have studied the long-term outcome of 408 primary medial St George Sled unicompartmental arthroplasties of the knee and 531 primary Kinematic total knee arthroplasties using survivorship analysis. The operations were performed by a number of surgeons under the supervision of two consultants at one orthopaedic centre. Prospective clinical assessment was carried out before and at 2, 5, 8, 10, 12 and 15 years after operation. Failure was defined as follows: revision or removal of the implant; the presence of moderate or severe pain; or ‘worst-case’ with all patients lost to follow-up.

Cumulative survival rates at ten years were calculated using life tables. The follow-up rate was 97%. At ten years, 25 medial sled arthroplasties and 20 Kinematic knee arthroplasties had been revised. With revision or removal as the survivorship endpoint at ten years there was a success rate of 87.5% for the medial sled and 89.6% for the Kinematic knee arthroplasty. When moderate or severe pain was included these rates became 79.4% for both arthroplasties. There was no statistically significant (p > 0.05) difference between the rates of survival for the two arthroplasties using either of the endpoint criteria.

Good or excellent results were recorded for 77.9% of the medial sled knees and 75.1% for the Kinematic knees. The former had 93.8% of cases with a final range of movement in excess of 90° compared with 83.7% for the Kinematic knees (p < 0.01). We conclude that at a single orthopaedic centre in the UK, the St Georg Sled medial compartment arthroplasty for appropriate specific indications offers predictable survivorship at ten years which is comparable with that of the Kinematic total knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 306 - 307
1 Mar 2002
ACKROYD CE NEWMAN JH