We compared a new fixation system, the Targon
Femoral Neck (TFN) hip screw, with the current standard treatment of
cannulated screw fixation. This was a single-centre, participant-blinded,
randomised controlled trial. Patients aged 65 years and over with
either a displaced or undisplaced intracapsular fracture of the
hip were eligible. The primary outcome was the risk of revision
surgery within one year of fixation. A total of 174 participants were included in the trial. The absolute
reduction in risk of revision was of 4.7% (95% CI 14.2 to 22.5)
in favour of the TFN hip screw (chi-squared test, pĀ = 0.741), which
was less than the pre-specified level of minimum clinically important
difference. There were no significant differences in any of the
secondary outcome measures. We found no evidence of a clinical difference in the risk of
revision surgery between the TFN hip screw and cannulated screw
fixation for patients with an intracapsular fracture of the hip. Cite this article:
To study the measurement properties of a joint specific patient
reported outcome measure, a measure of capability and a general
health-related quality of life (HRQOL) tool in a large cohort of
patients with a hip fracture. Responsiveness and associations between the Oxford Hip Score
(a hip specific measure: OHS), ICEpop CAPability (a measure of capability
in older people: ICECAP-O) and EuroQol EQ-5D (general health-related
quality of life measure: EQ-5D) were assessed using data available
from two large prospective studies. The three outcome measures were assessed
concurrently at a number of fixed follow-up time-points in a consecutive
sequence of patients, allowing direct assessment of change from
baseline, inter-measure associations and validity using a range
of statistical methods.Objectives
Methods
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for independent patients with displaced intracapsular fractures
of the proximal femur. The recognised alternatives are hemiarthroplasty
and total hip replacement. At present there is no established standard
of care, with both types of arthroplasty being used in many centres.
The principal advantages of total hip replacement are a functional
benefit over hemiarthroplasty and a reduced risk of revision surgery.
The principal criticism is the increased risk of dislocation. We
believe that an alternative acetabular component may reduce the
risk of dislocation but still provide the functional benefit of
total hip replacement in these patients. We therefore propose to
investigate the dislocation risk of a dual-mobility acetabular component
compared with standard polyethylene component in total hip replacement
for independent patients with displaced intracapsular fractures
of the proximal femur within the framework of the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for patients with unstable trochanteric proximal
femoral fractures. The recognised treatment alternatives are extramedullary
fixation usually with a sliding hip screw and intramedullary fixation
with a cephalomedullary nail. Current evidence suggests that best
results and lowest complication rates occur using a sliding hip screw.
Complications in these difficult fractures are relatively common
regardless of type of treatment. We believe that a novel device,
the X-Bolt dynamic plating system, may offer superior fixation over
a sliding hip screw with lower reoperation risk and better function.
We therefore propose to investigate the clinical effectiveness of
the X-bolt dynamic plating system compared with standard sliding
hip screw fixation within the framework of a the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. The National Hip Fracture
Audit currently provides a framework for service evaluation. This
evaluation is based upon the assessment of process rather than assessment
of patient-centred outcome and therefore it fails to provide meaningful
data regarding the clinical effectiveness of treatments. This study
aims to capture data from the cohort of patients who present with
a fracture of the proximal femur at a single United Kingdom Major
Trauma Centre. Patient-centred outcomes will be recorded and provide
a baseline cohort within which to test the clinical effectiveness
of experimental interventions.
The ideal form of fixation for displaced, extra-articular
fractures of the distal tibia remains controversial. In the UK, open
reduction and internal fixation with locking-plates and intramedullary
nailing are the two most common forms of treatment. Both techniques
provide reliable fixation but both are associated with specific
complications. There is little information regarding the functional
recovery following either procedure. We performed a randomised pilot trial to determine the functional
outcome of 24 adult patients treated with either a locking-plate
(n = 12) or an intramedullary nailing (n = 12). At six months, there
was an adjusted difference of 13 points in the Disability Rating
Index in favour of the intramedullary nail. However, this was not
statistically significant in this pilot trial (p = 0.498). A total
of seven patients required further surgery in the locking-plate
group and one in the intramedullary nail group. This study suggests that there may be clinically relevant, functional
differences in patients treated with nail