header advert
Results 21 - 40 of 52
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 538 - 541
1 Apr 2007
De Haan R Campbell P Reid S Skipor AK De Smet K

A prospective study of serum and urinary ion levels was undertaken in a triathlete who had undergone a metal-on-metal resurfacing arthroplasty of the hip four years previously. The one month study period included the final two weeks of training, the day of the triathlon, and the two weeks immediately post-race. Serum cobalt and chromium levels did not vary significantly throughout this period, including levels recorded on the day after the 11-hour triathlon. Urinary excretion of chromium increased immediately after the race and had returned to pre-race levels six days later. The clinical implications are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 16 - 20
1 Jan 2007
Gill HS Campbell PA Murray DW De Smet KA

Resurfacing arthroplasty of the hip is being used increasingly as an alternative to total hip replacement, especially for young active patients. There is concern about necrosis of the femoral head after resurfacing which can result in fracture and loosening. Most systems use a cemented femoral component, with the potential for thermal necrosis of the cancellous bone of the reamed femoral head. We used thermal probes to record temperatures close to the cement-bone interface during resurfacing arthroplasty.

The maximum temperature recorded at the cement-bone interface in four cases was approximately 68°C which was higher than that reported to kill osteocytes. A modified surgical technique using insertion of a suction cannula into the lesser trochanter, generous pulsed lavage and early reduction of the joint significantly reduced the maximum recorded cancellous bone temperature to approximately 36°C in five cases (p = 0.014).

We recommend the modified technique since it significantly reduces temperatures at the cement-bone interface.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 734 - 739
1 Jun 2006
Campbell DG Duncan WW Ashworth M Mintz A Stirling J Wakefield L Stevenson TM

A series of 100 consecutive osteoarthritic patients was randomised to undergo total knee replacement using a Miller-Galante II prosthesis, with or without a cemented polyethylene patellar component. Knee function was evaluated using the American Knee Society score, Western Ontario and McMaster University Osteoarthritis index, specific patellofemoral-related questions and radiographic evaluation until the fourth post-operative year, then via questionnaire until ten years post-operatively. A ten-point difference in the American Knee Society score between the two groups was considered a significant change in knee performance, with α and β levels of 0.05.

The mean age of the patients in the resurfaced group was 71 years (53 to 88) and in the non-resurfaced group was 73 years (54 to 86).

After ten years 22 patients had died, seven were suffering from dementia, three declined further participation and ten were lost to follow-up. Two patients in the non-resurfaced group subsequently had their patellae resurfaced. In the resurfaced group one patient had an arthroscopic lateral release. There was no significant difference between the two treatment groups: both had a similar deterioration of scores with time, and no further patellofemoral complications were observed in either group.

We are unable to recommend routine patellar resurfacing in osteoarthritic patients undergoing total knee replacement on the basis of our findings.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 35 - 39
1 Jan 2006
Beaulé PE Campbell PA Hoke R Dorey F

During hip resurfacing arthroplasty, excessive valgus positioning or surgical technique can result in notching of the femoral neck. Although mechanical weakening and subsequent fracture of the femoral neck are well described, the potential damage to the retinacular vessels leading to an ischaemic event is relatively unknown. Using laser Doppler flowmetry, we measured the blood flow in 14 osteoarthritic femoral heads during routine total hip replacement surgery, before and after notching of the femoral neck. In ten hips there was a reduction in blood flow of more than 50% from the baseline value after simulated notching of the femoral neck. Our results suggest that femoral head vascularity in the osteoarthritic state is similar to the non-arthritic state, where damage to the extraosseous vessels can predispose to avascular necrosis. Surgeons who perform resurfacing arthroplasty of the hip should pay careful attention to these vessels by avoiding excessive dissection around the femoral neck and/or notching.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 309 - 310
1 Mar 2002
Campbell D


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 115 - 116
1 Jan 2001
Rai RK Londhe S Sinha S Campbell AC Aburiziq IS

Clostridium septicum gas gangrene (myonecrosis) is an acutely painful and rapidly fatal infection occurring in the absence of trauma. Urgent surgery is essential both to control pain and to ensure survival. Most patients who develop this infection have an underlying malignancy and clinicians should be aware of this association. We present a case of bifocal myonecrosis which to our knowledge has not been reported previously.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1207 - 1207
1 Nov 2000
ACHARYA AD BRUCE CE CAMPBELL D


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 807 - 812
1 Aug 2000
Haddad FS Masri BA Campbell D McGraw RW Beauchamp CP Duncan CP

The PROSTALAC functional spacer is made of antibiotic-loaded acrylic cement but has a small metal-on-polythene articular surface. We have used it as an interim spacer in two-stage exchange arthroplasty for infected total knee replacement. PROSTALAC allows continuous rehabilitation between stages as it maintains good alignment and stability of the knee and a reasonable range of movement. It also helps to maintain the soft-tissue planes, which facilitates the second-stage procedure.

We reviewed 45 consecutive patients, treated over a period of nine years. The mean follow-up was for 48 months (20 to 112). At final review, there was no evidence of infection in 41 patients (91%); only one had a recurrent infection with the same organism. There was improvement in the Hospital for Special Surgery knee score between stages and at final review. The range of movement was maintained between stages. Complications were primarily related to the extensor mechanism and stability of the knee between stages. Both of these problems decreased with refinement of the design of the implant.

The rate of cure of the infection in our patients was similar to that using other methods. Movement of the knee does not appear to hinder control of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 352 - 357
1 Apr 2000
Milošev L Antolič V Minovič A Cör A Herman S Pavlovčič V Campbell P

We describe three prostheses with cemented titanium-alloy stems and Al2O3 ceramic femoral heads which had to be revised after a mean period of implantation of 78 months. In each case, the neck of the prosthesis had been so severely worn that the profile was elliptical rather than circular. There was severe metallosis of the periprosthetic tissues. Metal particles isolated from the tissues were approximately one nanometre in size and the ratios of titanium, aluminium and vanadium in the particles were the same as in the original alloy. Histologically, the high concentration of metal particles masked the presence of high-density polyethylene (HDP) debris, but again particles about one nanometre in size were isolated from the tissues. The severe necrobiosis and necrosis noted were consistent with other reports of the presence of extensive wear particles in periprosthetic tissues. Wear is presumed to have occurred as a result of mismatch between the shape or size of the taper cone and the femoral head, or to changes in the geometry of loading due to migration of the cup. To facilitate early intervention, patients with this design of prosthesis should be monitored radiologically.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 877 - 878
1 Sep 1997
COLLIER AM CAMPBELL P


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 22 - 25
1 Jan 1996
Campbell DG Li P Oakeshott RD

Infection of human cartilage with HIV in vivo has not previously been reported. Specimens of articular cartilage taken at postmortem from ten patients who were HIV-positive were examined. Two had AIDS and eight were believed to have stage-2 disease.

The standard polymerase chain reaction (PCR) protocol was modified to allow semiquantitative analysis of the samples. Oligonucleotide primers labelled with 32P gamma-ATP were used to detect a segment of HIV DNA and a control DNA gene segment (HLA genome) to estimate the ratio of infected cells. The 32P-labelled PCR products were separated on acrylamide gels and visualised directly by autoradiography and computer densitometry.

Infection of human cartilage in vivo was demonstrated in nine of the ten samples in which the PCR analysis was positive. The other did not react sufficiently to produce detectable radiolabelled PCR product despite repeated DNA digestion and extraction. Cartilage infected with HIV could be a potential source of HIV when used in operations.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 313 - 318
1 Mar 1995
Lee A Campbell J Hoffman E

We reviewed 33 children with tuberculosis of the knee treated during the period from 1979 to 1991. All were treated with triple chemotherapy, using rifampicin, isoniazid and pyrazinamide for nine months. No patient had a synovectomy; surgery was limited to open biopsy or salvage procedures such as posterior release and arthrodesis for late stages of the disease. The radiological appearance of the knee at presentation predicted the outcome. The 30 patients with stage-1 (normal) or stage-2 (osteomyelitic) disease had excellent or good results; the three with narrowed joint spaces in stage 3 or stage 4 (arthritic) had fair or poor results. Early active mobilisation, as against long-term immobilisation, seemed to have no effect on the outcome of stage-1 or stage-2 disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 319 - 326
1 Mar 1995
Campbell J Hoffman E

We have reviewed 74 tuberculous hips in 73 children treated from 1950 to 1991. From 1979 to 1991 we treated 28 patients with rifampicin, isoniazid and pyrazinamide given for nine months (series A), using active mobilisation for the more recent cases. Before this, 46 hips had been treated with streptomycin and isoniazid with or without para-aminosalicyclic acid given for a mean of 18 months (series B), and all these patients were immobilised for a mean of 2.2 years. The radiological appearances at presentation as classified by Shanmugasundaram (1983) predicted the outcome. Most hips were of the 'normal' type (50% and 59% of series A and B respectively) followed by the dislocating type (25% and 13%) and the atrophic type (8% and 9%). There were good or excellent results in 93% of the 'normal' type. All the atrophic type had poor results. The dislocating type had a poor result if the joint space was narrow after reduction of the hip. Early mobilisation had no effect on the outcome of the 'normal' type of disease. The newer drug regimens allowed for shorter courses of treatment, but did not necessarily give a better outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 423 - 427
1 May 1994
Amstutz H Grigoris P Safran M Grecula M Campbell P Schmalzried T

Cemented Ti-6Al-4V components were used to resurface ten femoral heads in nine young adult patients with osteonecrosis of the femoral head (average age 32 years; range 20 to 51). There were eight hips at Ficat stage III and two at stage IV. Five hips have maintained satisfactory function for an average period of 11.2 years (10 to 12.2) with no radiographic evidence of component loosening or osteolysis; five have been revised after an average period of 7.8 years (3.3 to 10.3) for pain caused by deterioration of the acetabular cartilage. No component required revision for loosening and the specimens retrieved at revision showed no evidence of osteolysis despite burnishing of the titanium bearing surface and the presence of particulate titanium debris in the tissues.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 667 - 667
1 Jul 1993
Muirhead A Campbell A


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 161 - 162
1 Jan 1993
Campbell P Kossovsky N Schmalzried T


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 63 - 66
1 Jan 1992
Campbell A Rorabeck C Bourne R Chess D Nott L

A retrospective review of 148 consecutive porous-coated hip arthroplasties (PCA) showed an incidence of thigh pain of 13% one year after surgery, and 22% at two years. Positive correlations were made with femoral stem subsidence (greater than 2 mm) and with distal periosteal and endosteal bone formation. No positive correlations were made with parameters of bone quality or component fit. Resolution of pain occurred in one-third and an anti-inflammatory agent produced partial relief in two-thirds of the patients. We conclude that thigh pain is secondary to stem instability with distal stress transfer in the absence of stable proximal fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 540 - 540
1 May 1989
Montgomery S Campbell J


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 838 - 838
1 Nov 1988
Archibald D Protheroe K Stother I Campbell A


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 628 - 634
1 Aug 1988
Amis A Kempson S Campbell Miller J

The anterior cruciate ligament was replaced in rabbits, using implants of carbon or polyester filaments with known mechanical properties. The biocompatibility of the implants was assessed in detail using light microscopy, and scanning and transmission electron microscopy. Mechanical tests were made of stability, in comparison with normal joints and controls after excision of the ligament. Some carbon fibre implants broke down in vivo, allowing instability; the fragments caused chronic inflammation. Intact carbon implants did not induce the formation of neoligaments; they were covered by tissue, but there was no ingrowth. Polyester did not degrade mechanically and supported early collagenous ingrowth within the implant, even in the mid-joint space. It was concluded that there was no justification for the use of carbon fibres as anterior cruciate replacements; polyester appeared to be suitable.