header advert
Results 51 - 54 of 54
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 783 - 786
1 Sep 1991
Kim Y

Total hip arthroplasty was performed in 45 hips of 44 patients who had pyogenic arthritis of the hip during childhood. The average age of the patients was 36.4 years (range 19 to 50). The interval between active infection and arthroplasty ranged from 11 to 40 years, and average follow-up was 65.4 months (range 58 to 80). Specimens of tissue taken before and during operation gave negative cultures in all hips, and no patient had reactivation of infection. The mean functional rating of the hips was 58 points before operation and 90 at the final review. Complications were seen in 11 cases (24%), loosening of components occurred in six (13%) and one hip had to be revised for acetabular component migration. Acetabular allografts were required in 27 hips (60%). All allografts united but there was partial resorption of the graft in the non-weight-bearing area in all.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 779 - 783
1 Sep 1990
Kim Y

The incidence of deep vein thrombosis in 244 patients who had total knee replacement has been studied. In 120 the prosthesis was cemented and in 124 it was cementless. In all cases the replacement was primary and a porous-coated prosthesis with a porous-coated central tibial stem was used. Deep vein thrombosis was diagnosed by venography, and pulmonary embolism by perfusion scanning. The incidence of deep vein thrombosis in the cementless knees (23.8%) and in the cemented (25%) was approximately the same. The only significant predisposing factors for deep vein thrombosis in both groups were obesity, prolonged postoperative immobilisation, previous venous disease and hyperlipidaemia.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 412 - 417
1 May 1990
Kim Y

In 44 consecutive patients, 60 porous-coated anatomic total knee (PCA) prostheses with a porous-coated central tibial stem were implanted without using cement. The clinical results and bony remodelling have been assessed after five years' follow-up. The average Hospital for Special Surgery knee score was 33.1 before operation and 95.7 at the latest follow-up, while the average range of movement improved from 63 degrees to 123 degrees. No subsidence or migration of the components was seen. A radiodense line appeared around the components at six months to one year after the operation and became more dense with time. There was no evidence of bone resorption related to stress-shielding in the tibial plateau.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 756 - 760
1 Nov 1988
Kim Y Ko C Ahn J Yoon Y Kwak B

We report 60 patients with tuberculosis of the hip treated by Charnley low friction arthroplasty and followed for eight to 13 years. Eight of them had active tuberculosis of the hip at the time of operation, and all were covered by relatively short courses of antituberculous drugs. Our study suggests that arthroplasty can be recommended for these patients provided that adequate chemotherapy is given both before and after operation.