header advert
Results 1 - 3 of 3
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1128 - 1135
14 Sep 2020
Khoshbin A Haddad FS Ward S O hEireamhoin S Wu J Nherera L Atrey A

Aims

The rate of dislocation when traditional single bearing implants are used in revision total hip arthroplasty (THA) has been reported to be between 8% and 10%. The use of dual mobility bearings can reduce this risk to between 0.5% and 2%. Dual mobility bearings are more expensive, and it is not clear if the additional clinical benefits constitute value for money for the payers. We aimed to estimate the cost-effectiveness of dual mobility compared with single bearings for patients undergoing revision THA.

Methods

We developed a Markov model to estimate the expected cost and benefits of dual mobility compared with single bearing implants in patients undergoing revision THA. The rates of revision and further revision were calculated from the National Joint Registry of England and Wales, while rates of transition from one health state to another were estimated from the literature, and the data were stratified by sex and age. Implant and healthcare costs were estimated from local procurement prices and national tariffs. Quality-adjusted life-years (QALYs) were calculated using published utility estimates for patients undergoing THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 604 - 611
1 May 2009
Reay E Wu J Holland J Deehan D

We describe a cohort of patients with a high rate of mid-term failure following Kinemax Plus total knee replacement inserted between 1998 and 2001. This implant has been recorded as having a survival rate of 96% at ten years. However, in our series the survival rate was 75% at nine years. This was also significantly lower than that of subsequent consecutive series of PFC Sigma knee replacements performed by the same surgeon. No differences were found in the clinical and radiological parameters between the two groups. At revision the most striking finding was polyethylene wear. An independent analysis of the polyethylene components was therefore undertaken. Scanning electron microscopy revealed type 2 fusion defects in the ultra-high molecular weight polyethylene (UHMWPE), which indicated incomplete boundary fusion. Other abnormalities consistent with weak UHMWPE particle interface strength were present in both the explanted inserts and in unused inserts from the same period.

We consider that these type 2 fusion defects are the cause of the early failure of the Kinemax implants. This may represent a manufacturing defect resulting in a form of programmed polyethylene failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1021 - 1026
1 Sep 2004
Matsui Y Mirza SK Wu J Carter B Bellabarba C Shaffrey CI Chapman JR Eyre DR

Two collagen type IX gene polymorphisms that introduce a tryptophan residue into the protein’s triple-helical domain have been linked to an increased risk of lumbar disc disease. To determine whether a particular subset of symptomatic lumbar disease is specifically associated with these polymorphisms, we performed a prospective case-control study of 107 patients who underwent surgery of the lumbar spine. Patients were assigned to one of five clinical categories (fracture, disc degeneration, disc herniation, spinal stenosis without spondylolisthesis and spinal stenosis with spondylolisthesis) based on history, imaging results, and findings during surgery. Of the 11 tryptophan-positive patients, eight had spinal stenosis with spondylolisthesis and three had disc herniation. The presence of the tryptophan allele was significantly associated with African-American or Asian designation for race (odds ratio 4.61, 95% CI 0.63 to 25.35) and with the diagnosis of spinal stenosis with spondylolisthesis (odds ratio 6.81, 95% CI 1.47 to 41.95).

Our findings indicate that tryptophan polymorphisms predispose carriers to the development of symptomatic spinal stenosis associated with spondylolisthesis which requires surgery.