header advert
Results 1 - 1 of 1
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 26 - 26
1 Sep 2012
Zywiel MG Kosashvili Y Gross AE Safir O Lulu OB Backstein D
Full Access

Purpose

Infection following total knee arthroplasty is a devastating complication, requiring considerable effort on the part of the surgeon to eradicate the infection and restore joint function. Two-stage revision is the standard of care in the treatment of peri-prosthetic infection, using a temporary antibiotic-impregnated spacer between procedures. However, controversy remains concerning the use of static versus dynamic spacers, as well as the spacer material. The purpose of this study was to evaluate the clinical outcomes and complications of two-stage revision total knee arthroplasty in patients treated with a metal-on-polyethylene articulating spacer, as compared to those treated with a static antibiotic-impregnated cement spacer at the same centre.

Method

Twenty-seven knees in patients with a mean age of 65 years (range, 40 to 80 years) were treated with two-stage revision of an infected total knee arthroplasty using a metal-on-polyethylene dynamic prosthetic spacer fixed with antibiotic-impregnated cement. Clinical outcomes were evaluated using maximum active knee range of motion, as well as modified Knee Society knee scores and incidence of re-infection at a minimum one-year follow-up. The results were compared to those achieved at similar follow-up in 10 patients treated with a static cement spacer. Demographic profile as measured by age and gender, and pre-operative Knee Society scores and range of motion were similar between the two groups.