header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 44 - 44
1 Aug 2020
Li Z Geng Z Cui Z Wu S Zhu S Liang Y Yang X
Full Access

Surgical failure, mainly caused by loosening implants, causes great mental and physical trauma to patients. Improving the physicochemical properties of implants to achieve favourable osseointegration will continue to be the focus of future research. Strontium (Sr), a trace element, is often incorporated into hydroxyapatite (HA) to improve its osteogenic activity. Our previous studies have shown that miR-21 can promote the osteogenic differentiation of mesenchymal stem cells by the PI3K/β-catenin pathway. The aim of this study is to fabricate a SrHA and miR-21 composite coating and it is expected to have a favorable bone healing capability.

Ti discs (20 mm diameter and one mm thickness for the in vitro section) and rods (four mm diameter and seven mm length for the in vivo section) were prepared by machining pure Ti. The Ti cylinders were placed in a Teflon-lined stainless-steel autoclave for treating at 150°C for 24 h to form SrHA layer. The miR-21 was encapsulated in nanocapsules. The miR-21 nanocapsules were mixed with CMCS powder to form a gel-like sample and uniformly coated on the SrHA modifed Ti. Osteoblast-like MG63 cells were cultured on SrHA and miR-21 modified Ti, Cell proliferation activity and osteogenesis-related gene expression were evaluated. A bone defect model was established with mature New Zealand to evaluate the osseointegration. Cylindrical holes (four mm in diameter) were created at the distal femur and tibial plateau. Each rabbit was implanted with four of the aforementioned rods (distal femur and tibial plateau of the hind legs). After implantation for one, two and three months, the rabbits were observed by X-ray and scanned using u-CT. Histological and Immunohistochemical analysis were performed to examine the osteogenic markers. A biomechanical push-in test was used to assess the bone-implant bonding strength.

Both SrHA nanoparticles with good superhydrophilicity and miR-21 nanocapsules with uniform sizes were distributed evenly on the surface of the Ti. In vitro experiments revealed that the composite coating was beneficial to osteoblast proliferation, differentiation and mineralization. In vivo evaluations demonstrated that this coating could not only promote the expression of angiogenic factor CD31 but also enhance the expression of osteoblastic genes to facilitate angio-osteogenesis. In addition, the composite coating also showed a decreased RANKL expression compared with the miR-21 coating. As a result, the SrHA/miR-21 composite coating promoted new bone formation and mineralization and thus enhanced osseointegration and bone-implant bonding strength.

A homogeneous SrHA and miR-21 composite coating was fabricated by generating pure Ti through a hydrothermal process, followed by adhering miR-21 nanocapsules. This coating combined the favorable physicochemical properties of SrHA and miR-21 that synergistically promoted angiogenesis, osteogenesis, osseointegration, bone mineralization and thus bone-implant bonding strength. This study provided a new strategy for surface modification of biomedical implants.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 27 - 27
1 May 2016
Sheng P Li Z Luo G Wang H Chen W Zhang Y Yang X
Full Access

Objective

To investigate the biomechanical mechanism and report preliminary clinical efficacy of eccentric rotational acetabular osteotomy (ERAO) when conduct treatment for developmental dysplasia of the hip (DDH).

Methods

Biomechanical model of the hip joint was established on six female cadaveric hips embalmed by formalin and stimulate ERAO was then performed on the model. Vertical force was loaded on the cadaveric spine from 0 N to 500 N and strain value on femoral head was measured preoperatively and postoperatively when loading force on spine reached the point of 100, 200, 300, 400 and 500 N. Stress value were then calculated base on the measurements. Besides, we reported postoperative follow up cases which were underwent ERAO to treat DDH in our hospital from July 2007 to October 2014. A total of 25 patients (26 hips) were reported, including 6 males and 19 females. Age varies from 11 to 57 years old, and the average age was 31 years old. Postoperative hip function was evaluated by Harris hip score and anteroposterior X⁃ray of pelvic was taken preoperatively and postoperatively to measure the Acetabular⁃head index (AHI), CE angle and Sharp angle.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 4 - 4
1 Jan 2016
Yang X Chen W Yu S Zhang Y Luo G Wang H Sheng P
Full Access

Objective

To investigate the biomechanical basis and report preliminary clinical efficacy of eccentric rotational acetabular osteotomy (ERAO) when treating developmental dysplasia of the hip (DDH).

Methods

Biomechanical model of the hip joint was established on cadaveric hips. After performed ERAO on the biomechanical model, we explored the impact of this surgery on biomechanics of the hip joint. Meanwhile, we reported postoperative follow-up cases who underwent ERAO in our hospital between November 2007 to July 2012. A total of 14 patients (15 hips) were reported, including 4 males and 10 females, mean age was 30 years old. Harris hip score was defined as clinical evaluation standard and radiographic assessment was based on the measurement and further comparison of pre- and post-operative AHI (Acetabular-head index), CE angle (Center-edge angle) and Sharp angle.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 5 - 5
1 Jan 2016
Li Z Zhou Y Zhang Y Luo G Yang X Li C Liao W Sheng P
Full Access

Implant-related infection (IRI) is closely related to the local immunity of peri-implant tissues. The generation of reactive oxygen species (ROS) in activated macrophages plays a prominent role in the innate immune response. In previous studies, we indicated that implant wear particles promote endotoxin tolerance by decreasing the release of proinflammatory cytokines. However, it is unclear whether ROS are involved in the damage of the local immunity of peri-implant tissues. In the present study, we assessed the mechanism of local immunosuppression using titanium (Ti) particles and/or lipopolysaccharide (LPS) to stimulate RAW 264.7 cells. The results indicate that the Ti particles induced the generation of a moderate amount of ROS through nicotinamide adenine dinucleotide phosphate oxidase-1 (NOX-1), but not through catalase. Pre-exposure to Ti particles inhibited ROS generation and extracellular regulated protein kinase (ERK) activation in LPS-stimulated macrophages. These findings indicate that chronic stimulation by Ti particles may lead to a state of oxidative stress and persistent inflammation, which may result in the attenuation of the immune response of macrophages to bacterial components such as LPS. Eventually, immunosuppression develops in peri-implant tissues, which may be a risk factor for IRI.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 9 - 9
1 Dec 2015
Dvorzhinskiy A Perino G Chojnowski R Van Der Meulen M Ross F Bostrom M Yang X
Full Access

To test the hypothesis that: CERAMENT[™]|G (C-G) would improve new bone growth and decrease infection rate after debridement as compared with 1) CERAMENT|BONE VOID FILLER (CBVF) and 2) no void filler in a rat osteomyelitis model.

72 Sprague Dawley rats were injected with 1.5 × 10∧6 CFU of S. aureus into a drill hole in the right tibia. After 3 weeks, the osteomyelitic defect was debrided, and filled with either: 1) C-G (n=32), 2) CBVF (n=20), or 3) nothing (n=20). 6 weeks after the second surgery, 20 rats from each group were sacrificed and the right tibias were harvested. A long-term group (n=12) of C-G treated rats were also sacrificed at 6 months after the second surgery. The tissues were sonicated and the colony forming units in the sonicate were quantified by serial dilutions and culture. MicroCT was used to quantify the new bone growth (BV/TV) in the debrided osteomyelitic void. Histological samples were analyzed for the presence of a neutrophil response by a blinded pathologist.

(*: p<0.05)

Positive cultures in:

○ 30% of animals treated with CBVF

○ 25% of animals treated with no void filler

○ 0% of animals treated with C-G (*)

Neutrophil reaction in:

○ 35% of animals treated with CBVF

○ 50% of animals treated with no void filler

○ 0% of animals treated with C-G (*)

The BV/TV in:

○ C-G treated rats was 24% greater than CBVF treated rats (*)

○ C-G treated rats was 94% greater than rats treated with no void filler (*)

○ CBVF treated rats was 56% greater than rats treated with no void filler (*)

Animals sacrificed at 6 months which were treated with C-G did not have any evidence of infection by culture or histology. The bone mass of the implanted limb was higher than the contralateral (non-operated) side.

CERAMENT|G decreased the rate of infection and increased new bone growth as compared with both CBVF and no void filler in a debrided osteomyelitic environment. Animals treated with C-G at 6 months showed no evidence of infection and retained a higher bone mass relative to the contralateral (non-operated) side.

This study supports the use of CERAMENT|G as a readily available void filler which could be used in osteomyelitic environments after debridement.