header advert
Results 1 - 7 of 7
Results per page:
Bone & Joint Open
Vol. 3, Issue 7 | Pages 549 - 556
1 Jul 2022
Poacher AT Bhachoo H Weston J Shergill K Poacher G Froud J

Aims

Evidence exists of a consistent decline in the value and time that medical schools place upon their undergraduate orthopaedic placements. This limited exposure to trauma and orthopaedics (T&O) during medical school will be the only experience in the speciality for the majority of doctors. This review aims to provide an overview of undergraduate orthopaedic training in the UK.

Methods

This review summarizes the relevant literature from the last 20 years in the UK. Articles were selected from database searches using MEDLINE, EMBASE, ERIC, Cochrane, and Web of Science. A total of 16 papers met the inclusion criteria.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 133 - 133
1 Sep 2012
Weston-Simons J Pandit H Haliker V Price A Dodd C Popat M Murray D
Full Access

Introduction

The peri-operative analgesic management of patients having either Total Knee Replacement (TKR) or Unicompartmental Knee Replacement (UKR) is an area that continues to have prominence, driven in part by the desire to reduce hospital stay, while maintaining high patient satisfaction. This is particularly relevant in the current climate of healthcare cost savings. We evaluated the role of “top up” intra-articular local anaesthetic injection after identifying that an appreciable number of patients in the unit suffered “breakthrough pain” on the first post-op day, when the effects of local analgesia are wearing off.

Method

43 patients, who were scheduled to have a cemented Oxford UKR, were prospectively recruited and randomised. All patients had the same initial anaesthetic regime of general anaesthesia, femoral nerve block and intra-operative intra-articular infiltration of the cocktail. All patients had a 16G multi-holed epidural catheter placed intra-articularly prior to wound closure. Patients had the same operative technique, post operative rehabilitation and rescue analgesia.

An independent observer recorded post-operative pain scores using a visual analogue score (1–10) every 6 hours and any rescue analgesia that was required. On the morning after surgery, 22 patients, (Group I), received 20 mls of 0.5% bupivicaine through the catheter whilst 21 patients, (Group II), had 20 mls of normal saline by the same observer, (who was blinded to the contents of the solution being injected), after which the catheter was removed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 422 - 422
1 Sep 2012
Weston-Simons J Pandit H Kendrick B Beard D Gibbons M Jackson W Gill H Price A Dodd C Murray D
Full Access

Introduction

The options for the treatment of the young active patient with unicompartmental symptomatic osteoarthritis and pre-existing Anterior Cruciate Ligament (ACL) deficiency are limited. Patients with ACL deficiency and end-stage medial compartment osteoarthritis are usually young and active. The Oxford Unicompartmental Knee Replacement (UKA) is a well established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis, but a functionally intact ACL is a pre-requisite for its satisfactory outcome. If absent, high failure rates have been reported, primarily due to tibial loosening. Previously, we have reported results on a consecutive series of 15 such patients in whom the ACL was reconstructed and patients underwent a staged or simultaneous UKA. The aim of the current study is to provide an update on the clinical and radiological outcomes of a large, consecutive cohort of patients with ACL reconstruction and UKA for the treatment of end-stage medial compartment osteoarthritis and to evaluate, particularly, the outcome of those patients under 50.

Methods

This study presents a consecutive series of 52 patients with ACL reconstruction and Oxford UKA performed over the past 10 years (mean follow-up 3.4 years). The mean age was 51 years (range: 36–67). Procedures were either carried out as Simultaneous (n=34) or Staged (n=18). Changes in clinical outcomes were measured using the Oxford Knee Score (OKS), the change in OKS (OKS=Post-op − Pre-op) and the American Knee Society Score (AKSS). Fluoroscopy assisted radiographs were taken at each review to assess for evidence of loosening, radiolucency progression, (if present), and component subsidence.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 249 - 249
1 Sep 2012
Kendrick B Weston-Simons J Sim F Gibbons M Pandit H Gill H Price A Dodd C Murray D
Full Access

Introduction

Radiolucencies beneath the tibial component are well recognized in knee arthroplasty; the aetiology and significance are poorly understood. Non-progressive narrow radiolucencies with a sclerotic margin are thought not to be indicative of loosening. Factors which decrease the incidence of radiolucencies include cementless fixation and the use of pulse lavage. Leg/component alignment or BMI do not influence radiolucency. We are not aware of any studies that have looked at the effect of load type on radiolucency.

The Oxford domed lateral tibial component was introduced to decrease the bearing dislocation rate that was unacceptably high with the flat tibial tray. However, the introduction of the domed tibial component alters the forces transmitted through the implant-cement-bone interface. As the Oxford UKR uses a fully congruent mobile bearing, the forces transmitted through the interface with a flat tray are compressive, except for the effect of friction. However, with the domed tibial component shear forces are introduced. The aim of this study was to assess the prevalence of radiolucency beneath the previous flat design and the new domed tibial tray.

Patients and methods

A consecutive series of 248 cemented lateral UKRs (1999–2009) at a single institution were assessed. The first 55 were with a flat tibia and the subsequent 193 with a domed component. One year post-op radiographs were assessed, by two observers, for the presence (full or partial) and distribution of radiolucency. The distribution and thickness of each radiolucency. Cases were excluded for missing or poorly aligned radiographs.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 382 - 382
1 Jul 2010
Harshavardhana N Hegarty J Freeman B Boszczyk B Dabke H Weston J Race A
Full Access

Purpose: To review the existing practice of coding in spinal surgery and ascertain its accuracy for surgical procedures, co-morbidities and complications.

Methods: A retrospective review of 70 cervical and 100 lumbar consecutive spinal surgeries performed since April 2006 was conducted. The clinical coding data and hospital notes were reviewed.

Results: Coding data of 5 cervical spine surgeries were not available. Of the 165 cases, the accuracy of primary procedural codes was 93.9% (90.8% cervical & 96% lumbar). This reduced to 77.6% (75.4% cervical & 79% lumbar) when the accuracy for entire description of performed surgery was considered. Medical co-morbidities were coded appropriately in 64.2% of the patients (55% cervical & 70% lumbar). The procedural codes did not specifically reflect the surgery performed and lacked reproducibility. Surgical levels were coded incorrectly in 9% of the cases. Cervical surgeries were coded as lumbar in 4 and posterior surgery as anterior in 3 cases respectively. The commonly missed co-morbidities were drug allergies, hypercholesterolemia, smoking and alcoholism. Post-op adverse events were coded in 75% of the cases (16/20 cervical & 5/8 lumbar). The accuracy was better for lumbar as compared to cervical spinal surgeries.

Conclusion: Coding is a universal language of communication and its accuracy is important not just for PbR, but for data quality, audit and research purposes too. The financial implications regarding PbR governed by HRG codes (dictated by OPCS 4.4 & ICD–10 codes) are discussed. Following this study, a clinical coding facilitation form has been introduced to improve data quality.

Ethics approval: None

Interest statement: None


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 236 - 236
1 Mar 2010
Harshavardhana N Hegarty J Weston J Race A Boszczyk B
Full Access

Introduction: Accurate & ethical coding is challenging and directly impacts on Payment by Results (PbR). The objectives were to review the existing pattern of coding for lumbar spinal surgery and ascertain its appropriateness & accuracy for surgical procedures, medical comorbidities and post-op complications.

Methods: A retrospective review of 100 consecutive lumbar spine surgeries operated from Apr2006–Jan2007 was conducted. The coding excel sheet, hospital notes and laboratory reports were reviewed.

Results: The primary procedural accuracy was 96%, however this reduced to 79% for the entire description of performed surgery. The procedural codes did not specifically reflect the surgery performed and lacked reproducibility. Spinal fusion codes were omitted and revision cases were coded as primary surgeries in 2 instances each. Surgical levels were coded incorrectly in 12 and harvest of iliac crest bone graft omitted in 4 cases respectively. Medical comorbidities were coded appropriately in 70%. The commonly missed comorbidities were drug allergies, hypercholesterolemia, smoking and alcoholism. Post-op adverse events were coded in 62.5% of the cases(5/8).

Conclusion: Coding is a universal language of communication amongst healthcare professionals. Its accuracy is important not just for PbR, but also for data quality, audit and research. The financial implications regarding PbR governed by Healthcare Resource Group (HRG) codes (dictated by Official population and census surveys [OPCS4.4] & International classification of diseases [ICD–10] codes) are discussed. The awareness of clinical coding is low amongst junior doctors. Literature emphasises qualification of coders, legible documentation by physicians and interaction between coders & clinicians.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 497 - 497
1 Sep 2009
Harshavardhana N Shahid R Freeman B Boszczyk B Hegarty Race A Weston J Grevitt M
Full Access

Introduction: Accurate and ethical coding is challenging and directly impacts on Payment by Results (PbR). The aims & objectives of this study were to review the existing pattern of coding for spinal surgery and ascertain its appropriateness & accuracy for surgical procedures, medical co-morbidities and post-op complications.

Methods: A retrospective review of 70 consecutive cervical and 100 consecutive lumbar spine patients who were operated from April 2006 onwards was conducted. The excel sheet provided by coding department, hospital notes – clinic letters, physicians’ entries, theatre notes and laboratory reports (biochemistry/microbiology/histology) – were reviewed. Of the 170 cases, 165 were available for analysis.

Results: Coding data of 5 patients who underwent cervical spine surgeries were not available. Of the 165 cases, the accuracy of primary procedural codes was 93.9% (90.8% cervical & 96% lumbar). However this reduced to 77.6% (75.4% cervical & 79% lumbar) when the accuracy for entire description of performed surgery was considered. The procedural codes did not specifically reflect the surgery performed and lacked reproducibility. Surgical levels were coded incorrectly in 9% of the cases. Cervical surgeries were coded as lumbar in 4 and posterior surgery as anterior in 3 cases respectively. Harvest of iliac crest bone graft was not coded in 5 cases. Medical comorbidities were coded appropriately in 64.2% of the patients (55% cervical & 70% lumbar). The commonly missed comorbidities were drug allergies, hypercholesterolemia, smoking and alcoholism. Post-op adverse events were coded in 75% of the cases (16/20 cervical & 5/8 lumbar). The accuracy was better for lumbar as compared to cervical spinal surgeries.

Conclusion: Coding is a universal language of communication amongst healthcare professionals. Its accuracy is important not just for PbR, but for data quality, audit and research purposes too. The financial implications regarding PbR governed by HRG codes (dictated by OPCS 4.4 & ICD–10 codes) are discussed. The awareness of clinical coding is low amongst junior doctors. Following this study, a clinical coding facilitation form has been introduced to improve data quality. Our plan is to close the audit loop and re-evaluate. Literature emphasises qualification of coders, legible documentation by physicians and interaction between coders and clinicians.