Introduction

In order to prepare hamstring autograft, suture fixation to the tendon is required to secure and handle the tendon during harvest and preparation. We use a simple, grasping suture which doesn't require suture of the tendon, thus saving time and avoiding violation of the graft itself. We present this technique, with results of mechanical testing compared to a standard whip suture, traditionally used to handle hamstring autograft.

Methods and materials

Twelve uniform ovine flexor tendons were prepared. A number two braided polyester suture was used in all cases. Six tendons were prepared with a standard, non-locking whip-suture, maintaining uniformity of suture bite and working length between samples. Six tendons were prepared with the utility suture, also taking care to maintain uniformity. The suture was applied by tying the thread around the tendon with a single-throw granny knot then symmetrically wrapping the suture ends from proximal to distal and securing with another single throw, allowing compression of the tendon with longitudinal tension on the suture. All the samples were tested to failure in uniaxial tension in a materials testing machine. Peak load values and load/displacement curves were acquired and results analysed with a two-sample T-test assuming significance at P<0.05.