Aim

Diagnosing or excluding a chronic prosthetic joint infection (PJI) prior to revision surgery can be a clinical challenge. To enhance accuracy of diagnosis, several biomarkers were introduced in recent years, but most are either expensive or not available as a rapid test. We compared the diagnostic accuracy of leucocyte esterase (€0.20 per sample), calprotectin (€20 per sample) and alpha defensin (€200 per sample).

Method

We prospectively evaluated PJI patients with chronic pain with or without prosthetic loosening between 2017 and 2018. Synovial fluid was collected prior to revision surgery. Leucocyte esterase was measured using a reagent strip (2+ considered as positive), and calprotectin and alpha defensin were measured using a lateral flow immunoassay. Intraoperative cultures (5 periprosthetic tissue samples, synovial fluid and sonication fluid) incubated for 9 days, were used as gold standard. At least two positive cultures of low-grade microorganisms with the same antibiogram were required to diagnose PJI.