header advert
Results 1 - 10 of 10
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 880 - 887
1 Aug 2023
Onodera T Momma D Matsuoka M Kondo E Suzuki K Inoue M Higano M Iwasaki N

Aims

Implantation of ultra-purified alginate (UPAL) gel is safe and effective in animal osteochondral defect models. This study aimed to examine the applicability of UPAL gel implantation to acellular therapy in humans with cartilage injury.

Methods

A total of 12 patients (12 knees) with symptomatic, post-traumatic, full-thickness cartilage lesions (1.0 to 4.0 cm2) were included in this study. UPAL gel was implanted into chondral defects after performing bone marrow stimulation technique, and assessed for up to three years postoperatively. The primary outcomes were the feasibility and safety of the procedure. The secondary outcomes were self-assessed clinical scores, arthroscopic scores, tissue biopsies, and MRI-based estimations.


Bone & Joint Open
Vol. 3, Issue 3 | Pages 261 - 267
22 Mar 2022
Abe S Kashii M Shimada T Suzuki K Nishimoto S Nakagawa R Horiki M Yasui Y Namba J Kuriyama K

Aims

Low-energy distal radius fractures (DRFs) are the most common upper arm fractures correlated with bone fragility. Vitamin D deficiency is an important risk factor associated with DRFs. However, the relationship between DRF severity and vitamin D deficiency is not elucidated. Therefore, this study aimed to identify the correlation between DRF severity and serum 25-hydroxyvitamin-D level, which is an indicator of vitamin D deficiency.

Methods

This multicentre retrospective observational study enrolled 122 female patients aged over 45 years with DRFs with extension deformity. DRF severity was assessed by three independent examiners using 3D CT. Moreover, it was categorized based on the AO classification, and the degree of articular and volar cortex comminution was evaluated. Articular comminution was defined as an articular fragment involving three or more fragments, and volar cortex comminution as a fracture in the volar cortex of the distal fragment. Serum 25-hydroxyvitamin-D level, bone metabolic markers, and bone mineral density (BMD) at the lumbar spine, hip, and wrist were evaluated six months after injury. According to DRF severity, serum 25-hydroxyvitamin-D level, parameters correlated with bone metabolism, and BMD was compared.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 60 - 60
1 May 2016
Suzuki K Hara N Mikami S
Full Access

Backgrounds

It is well accepted that gap balancing is one of the important step for total knee arthroplasty (TKA). In order to evaluate gap balancing during operation, many tension devises have been used and developed. However, during operation, proper load to be applied, ideal gap amount, appropriate angle formed between femoral component and tibial cut surface are not clearly defined. Understanding the relationship between applied load and gap pattern will provide important information. The purpose of this study is to precisely analyze gap amount and inclination in extension and flexion using digital analyzer during TKA and characterize gap pattern.

Methods

We analyzed 39 knees in 39 cases that underwent TKA with Scorpio NRG PS knee prosthesis operated by modified gap balancing technique. A customized digital knee balancer was manufactured applying load cell, angle sensor, and gap sensor in the selected part within offset seesaw type balancer (Fig 1). It can measure three values (gap, angle and force) at the same time and automatically record the values. After bone cut for femur, tibia, and patella, femoral component trial was inserted to the femur. Then gap length and inclination angle between femoral condyle surface and tibial cut surface was analyzed in extension and at 90 degrees knee flexion with gradually increasing opening torque. Inclination was expressed by positive degrees when lateral side opened. Serial data was recorded automatically and analyzed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 39 - 39
1 Jan 2016
Suzuki K Hara N Mikami S Tomita T Iwamoto K Yamazaki T Sugamoto K Matsuno S
Full Access

Backgrounds

Most of in vivo kinematic studies of total knee arthroplasty (TKA) have reported on varus knee. TKA for the valgus knee deformity is a surgical challenge. The purposes of the current study are to analyze the in vivo kinematic motion and to compare kinematic patterns between weight-bearing (WB) and non-weight-bearing (NWB) knee flexion in posterior-stabilized (PS) fixed-bearing TKA with pre-operative valgus deformity.

Methods

A total of sixteen valgus knees in 12 cases that underwent TKA with Scorpio NRG PS knee prosthesis operated by modified gap balancing technique were evaluated. The mean preoperative femorotibial angle (FTA) was 156°±4.2°. During the surgery, distal femur and proximal tibia was cut perpendicular to the mechanical axis of each bone. After excision of the menisci and cruciate ligaments, balancer (Stryker joint dependent kinematics balancer) was inserted into the gap between both bones for evaluation of extension gap. Lateral release was performed in extension. Iliotibial bundle (ITB) was released from Gerdy tubercle then posterolateral capsule was released at the level of the proximal tibial cut surface. If still unbalanced, pie-crust ITB from inside-out was added at 1 cm above joint line until an even lateral and medial gap had been achieved. Flexion gap balance was obtained predominantly by the bone cut of the posterior femoral condyle. Good postoperative stability in extension and flexion was confirmed by stress roentgenogram and axial radiography of the distal femur. We evaluated the in vivo kinematics of the knee using fluoroscopy and femorotibial translation relative to the tibial tray using a 2-dimentional to 3-dimensional registration technique.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 88 - 88
1 Jan 2016
Nishinaka N Suzuki K Matsuhisa T Uehara T Nagai S Tsutsui H
Full Access

Purpose

Chronic massive rotator cuff tears are challenging to repair completely because of the development of tendon retraction with inelasticity, muscle atrophy and fatty infiltration. The objective of this study was to investigate the clinical outcome and MRI findings after arthroscopic superior capsule reconstruction (ASCR) for symptomatic irreparable rotator cuff tears.

Methods

From 2011 to 2013, 12 shoulders in 12 consecutive patients (mean, 70.8 years) with irreparable massive rotator cuff tears underwent ASCR using fascia lata. We used suture anchors to attach the graft medially to the glenoid superior tubercle and laterally to the greater tuberosity as same technique by Mihata et al. We added side-to-side sutures between the graft and infraspinatus tendon and between the graft and residual anterior supraspinatus/subscapularis tendon to improve force coupling. Physical examination, clinical rating system, and magnetic resonance imaging (MRI) were performed before surgery; at 6 and 12 months after surgery; and 6 months thereafter. Average follow-up was 19.1 months (12 to 28 months) after surgery. We assessed patients preoperatively by using the scoring systems of the shoulder index of the American Shoulder and Elbow Surgeons (ASES), the Japanese Orthopaedic Association, and the University of California, Los Angeles.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1155 - 1157
1 Sep 2007
Suzuki K Kawachi S Matsubara M Morita S Jinno T Shinomiya K

We present a series of 30 uncemented total hip replacements performed between June 1985 and January 2002 with a mean follow-up of seven years (5 to 20) in 27 patients who had previously undergone a valgus intertrochanteric osteotomy. No further osteotomy was undertaken to enable hip replacement. We used a number of uncemented modular or monoblock femoral components, acetabular components and bearings. The patients were followed up clinically and radiologically. We report 100% survival of the femoral component. One acetabular component was revised at five years post-implantation for aseptic loosening. We noted cortical hypertrophy around the tip of the monoblock stems in six patients. We believe that modular femoral components should be used when undertaking total hip replacement in patients who have previously undergone valgus femoral osteotomy.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 963 - 968
1 Sep 2003
Koga H Matsubara M Suzuki K Morita S Muneta T

We have investigated the factors which affect the progression of osteoarthritis after rotational acetabular osteotomy (RAO).

Between 1984 and 1998, we treated 60 dysplastic hips by RAO. The mean age at surgery was 31.6 years (13 to 51) and the mean period of follow-up was 4.6 years (2 to 9.5). The thickness of the articular cartilage on the weight-bearing area, pre- and postoperative acetabular cover, and the sphericity of the femoral head were used for radiological assessment.

The osteoarthritis did not progress in 39 hips. Significant factors which affected the radiological grade included sphericity of the femoral head and the postoperative acetabular cover. The surgical approach and preoperative acetabular cover did not affect the progression of osteoarthritis. Patients were divided into two groups according to the surgical approach used, either conventional (23 hips) or modified (37 hips). Significant factors included the postoperative acetabular cover in the modified approach, and the sphericity of the femoral head in the conventional approach.

It is critical that the postoperative cover is sufficient, especially when RAO is carried out using our modified technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1130 - 1132
1 Nov 2001
Asano H Matsubara M Suzuki K Morita S Shinomiya K

We carried out a prospective, randomised study of 62 patients to determine the efficacy of a foot sole pump (the A-V Impulse System) for the prevention of pulmonary embolism (PE) after hip surgery. PE was assessed by pulmonary perfusion scintigraphy before and after operation. We defined a PE as any new scintigraphic defect which was larger than a bronchopulmonary segment.

The incidence of PE was 55% in the control group and 21% in the treatment group. The foot sole pump significantly reduced the incidence of PE (p = 0.008) and we encountered no side-effects from its use.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 240 - 244
1 Mar 1999
Ishida Y Ohmori K Inoue H Suzuki K

We reviewed the radiographs of 325 unselected patients with defects in the pars interarticularis of L5 to study whether the incidence of vertebral slip in spondylolysis of L5 remained unchanged after the age of 20 years. MRI was also carried out on 111 of the patients to investigate the relationship between the shape of the transverse process of L5 and the degeneration of the discs adjacent to this level.

The incidence of spondylolisthesis increased with age from 17% in the second decade to 51% in the sixth. The transverse process was significantly more slender in patients with less degeneration at L4/5 and advanced degeneration at L5/S1 than in patients with advanced degeneration at L4/5 and less degeneration at L5/S1. Vertebral slip secondary to an isthmic defect of L5 after the age of 20 years was confirmed and the adjacent disc degeneration was significantly related to the vertical thickness of the transverse process of L5.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 771 - 773
1 Sep 1995
Ohmori K Ishida Y Takatsu T Inoue H Suzuki K

We studied the aetiology of vertebral slip in a long-term follow-up of 22 adult patients with isthmic spondylolysis or spondylolisthesis of L5. Of the 18 with spondylolysis without slip, 13 showed no slip after ten years, but five developed displacement of over 5%. All four patients with spondylolisthesis showed progression of the slip. We found that the vertical thickness of the transverse process of L5 was significantly greater (p < 0.01) in the 13 patients with no slip than in the other two groups. The relationship of vertebral slip to the shape of the transverse processes of L5 may be explained by differences in the bulk or physiological strength of the posterior bands of the iliolumbar ligament.