Kitamura N Arakaki K Susuda K Kondo E Yasuda K
Full Access

Introduction: While plain radiographs are the clinical standard for routine follow-up after total knee arthroplasty (TKA), periprosthetic osteolysis can be difficult to identify on radiographs because it is often obscured by the metallic prosthesis. This study sought to evaluate the pattern and size of periprosthtic osteolytic lesions after TKA in patients with rheumatoid arthritis using multi-detector computed tomography (MDCT).

Methods: We evaluated 25 primary cemented alumina-ceramic TKAs (LFA-I, Kyocera) using minimum 10-year CT scans. All TKAs had an alumina-ceramic femoral component, a titanium tibial baseplate with a poly-ethylene insert, and a polyethylene patella component, which had been fixed with cement. The average age at the time of surgery was 54.1 years. The average time interval between surgery and the computed tomography scan was 12.6 years. None of the patients in this study documented periprosthetic infection or had undergone bone grafting.

Results: The MDCT detected 31 lesions in 12 knees: 23 femoral and 8 tibial lesions.

All lesions occurred around the prosthetic rim, and the mean size of osteolysis per knee was 2.1 +/−1.5 cc (range, 0.4–4.7 cc). Only seven lesions in 6 knees were diagnosed as osteolysis on plain radiographs: 2 lesions at anterior femoral condyle and 5 lesions at tibial condyles. None of the lesions around the posterior condylar flanges detected on CT was identified on plain radiographs. None of the implants showed radiographic loosening or required reoperation.

Discussion: As the alumina-ceramic TKA allowed the CT scans to obtain clear images with little metal artifact, we could easily detect lesions and joint space communication. This study demonstrated that plain radiographs underestimated osteolysis, and that lesions around posterior femoral condyles were the most difficult to identify on radiographs. Although most of the lesions were small and may be of little clinical importance, this study confirmed that MDCT can accurately detect osteolysis and measure lesion volumes in alumina-ceramic TKA.