Proximal femoral focal deficiency is a congenital disorder of malformation of the proximal femur and/or the acetabulum. Patients present with limb length discrepancy and clinical features along a spectrum of severity. As these patients progress through to skeletal maturity and on to adulthood, altered biomechanical demands lead to progression of arthropathy in any joint within the lower limb. Abnormal anatomy presents a challenge to surgeons and conventional approaches and implants may not necessarily be applicable.

We present a case of a 62-year-old lady with unilateral proximal femoral focal deficiency (suspected Aitken Class A) who ambulated with an equinus prosthesis for her entire life. She presented with ipsilateral knee pain and instability due to knee arthritis but could not tolerate a total knee arthroplasty due to poor quadriceps control.

A custom osteointegration prosthesis was inserted with a view to converting to the proximal segment to a total hip replacement if required. The patient went on to develop ipsilateral symptomatic hip arthritis but altered acetabular anatomy required a custom tri-flange component (Ossis, Christchurch, New Zealand) and a custom proximal femoral component to link with the existing osseointegration component (Osseointegration Group of Australia, Sydney, Australia) were designed and implanted.

The 18 month follow up of the custom hip components showed that the patient had Oxford hip scores that were markedly improved from pre-operatively. Knee joint heights were successfully restored to equal when the patient's prosthesis was attached. The patient describes feeling like “a normal person”, walks unaided for short distances and can ambulate longer distances with crutches.

Advances in design and manufacture of implants have empowered surgeons to offer life improving treatments to patients with challenging anatomy. Using a custom acetabular tri-flange and osseointegration components is one possible solution to address symptomatic ipsilateral hip and knee arthropathy in the context of PFFD in adulthood.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 4 - 4
10 Feb 2023
Sundaram A Hockley E Hardy T Carey Smith R
Full Access

Rates of prosthetic joint infection in megaprostheses are high. The application of silver ion coating to implants serves as a deterrent to infection and biofilm formation.

A retrospective review was performed of all silver-coated MUTARS endoprosthetic reconstructions (SC-EPR) by a single Orthopaedic Oncology Surgeon. We examined the rate of component revision due to infection and the rate of infection successfully treated with antibiotic therapy. We reviewed overall revision rates, sub-categorised into the Henderson groupings for endoprosthesis modes of failure (Type 1 soft tissue failure, Type 2 aseptic loosening, Type 3 Structural failure, Type 4 Infection, Type 5 tumour progression).

283 silver-coated MUTARS endoprosthetic reconstructions were performed for 229 patients from October 2012 to July 2022. The average age at time of surgery was 58.9 years and 53% of our cohort were males. 154 (71.3%) patients underwent SC-EPR for oncological reconstruction and 32 (14.8%) for reconstruction for bone loss following prosthetic joint infection(s). Proximal femur SC-EPR (82) and distal femur (90) were the most common procedures. This cohort had an overall revision rate of 21.2% (60/283 cases). Component revisions were most commonly due to Type 4 infection (19 cases), Type 2 aseptic loosening/culture negative disease (15 cases), and Type 1 dislocation/soft tissue (12 cases).

Component revision rate for infection was 6.7% (19 cases). 15 underwent exchange of implants and 4 underwent transfemoral amputation due to recalcitrant infection and failure of soft tissue coverage. This equates to a limb salvage rate of 98.3%. The most common causative organisms remain staphylococcus species (47%) and polymicrobial infections (40%).

We expand on the existing literature advocating for the use of silver-coated endoprosthetic reconstructions. We provide insights from the vast experience of a single surgeon when addressing patients with oncological and bone loss-related complex reconstruction problems.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 1 - 1
10 Feb 2023
Sundaram A Perianayagam G Hong A Mar J Lo H Lawless A Carey Smith R
Full Access

The Australia and New Zealand Sarcoma Association established the Sarcoma Guidelines Working Party to develop national guidelines for the management of Sarcoma. We asked whether surgery at a specialised centre improves outcomes. A systematic review was performed of all available evidence pertaining to paediatric or adult patients treated for bone or soft tissue sarcoma at a specialised centre compared with non-specialised centres. Outcomes assessed included local control, limb salvage rate, 30-day and 90-day surgical mortality, and overall survival.

Definitive surgical management at a specialised sarcoma centre improves local control as defined by margin negative surgery, local or locoregional recurrence, and local recurrence free survival. Limb conservation rates are higher at specialised centres, due in part to the depth of surgical experience and immediate availability of multidisciplinary and multimodal therapy. A statistically significant correlation did not exist for 30-day and 90-day mortality between specialised centres and non-specialised centres. The literature is consistent with improved survival when definitive surgical treatment is performed at a specialised sarcoma centre.

Evidence-based recommendation: Patients with suspected sarcoma to be referred to a specialised sarcoma centre for surgical management to reduce the risk of local recurrence, surgical complication, and to improve limb conservation and survival.

Practice point: Patients with suspected sarcoma should be referred to a specialised sarcoma centre early for management including planned biopsy.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 3 - 3
10 Feb 2023
Sundaram A Woods J Clifton L Alt V Clark R Carey Smith R
Full Access

Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany).

At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both patients remain asymptomatic. 3 patients were readmitted for dislocations, 1 of whom had 5 dislocations within 3 weeks post-operatively and was immobilised in an abduction brace to address a lack of muscle tone and has not had a revision of their components.

Utilising navigation with meticulous implant design and construction; augmented with an ultrathin plasma coating of silver particles embedded between layers of siloxane with controlled and long-term generation of silver ion diffusion has led to outstanding outcomes in this series of 12 custom acetabular and hemipelvis reconstructions. No patients were revised for infection and no patients show signs of failure of bone on growth and incorporation. Hip instability remains a problem in these challenging mechanical environments and we continue to reassess our approach to this multifaceted problem.


Bone & Joint Open
Vol. 1, Issue 7 | Pages 438 - 442
22 Jul 2020
Stoneham ACS Apostolides M Bennett PM Hillier-Smith R Witek AJ Goodier H Asp R

Aims

This study aimed to identify patients receiving total hip arthroplasty (THA) for trauma during the peak of the COVID-19 pandemic in the UK and quantify the risks of contracting SARS-CoV-2 virus, the proportion of patients requiring treatment in an intensive care unit (ICU), and rate of complications including mortality.

Methods

All patients receiving a primary THA for trauma in four regional hospitals were identified for analysis during the period 1 March to 1 June 2020, which covered the current peak of the COVID-19 pandemic in the UK.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 101 - 101
1 Feb 2020
Abbruzzese K Byrd Z Smith R Valentino A Yanoso-Scholl L Harrington MA Parsley B
Full Access

Introduction

Total hip arthroplasty (THA) is a physically demanding procedure where the surgeon is subject to fatigue with increased energy expenditure comparable to exercise[1]. Robotic technologies have been introduced into operating rooms to assist surgeons with ergonomically challenging tasks and to reduce overall physical stress and fatigue[2]. Greater exposure to robotic assisted training may create efficiencies that may reduce energy expenditure[3]. The purpose of this study was to assess surgeon energy expenditure during THA and perceived mental and physical demand.

Methods

12 THAs (6 cadavers) randomized by BMI were performed by two surgeons with different robotic assisted experience. Surgeon 1 (S1) had performed over 20 robotic assisted THAs on live patients and Surgeon 2 (S2) had training on 1 cadaver with no patient experience. For each cadaver, laterality was randomized and manual total hip arthroplasty (MTHA) was performed first on one hip and robotic assisted total hip arthroplasty (RATHA) on the contralateral hip. A biometric shirt collected surgeon data on caloric energy expenditure (CEE) throughout acetabular reaming (AR) and acetabular implantation (AI) for each THA procedure. Surgeon mental and physical demand was assessed after each surgery. Scores were reported from 1–10, with 10 indicating high demand. A paired sample t-test was performed between MTHA and RATHA within each surgeon group with a confidence interval of (α =0.05).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 7 - 7
1 May 2016
Griffiths J Abouel-Enin S Yates P Carey-Smith R Quaye M Latham J
Full Access

In a society whereby the incidence of obesity is increasing and medico-legal implications of treatment failure are more frequently ending with the consulting doctor, clarity is required as to any restrictions placed on common orthopaedic implants by manufacturing companies. The aim of this study was to identify any restrictions placed on the commonly used femoral stem implants in total hip replacement (THR) surgery, by the manufacturers, based on patient weight. The United Kingdom (UK) National Joint Registry (NJR) was used to identify the five most commonly used cemented and uncemented femoral stem implants during 2012. The manufacturing companies responsible for these implants were asked to provide details of any weight restrictions placed on these implants. The Corail size 6 stem is the only implant to have a weight restriction (60Kg). All other stems, both cemented and uncemented, were free of any restrictions. Fatigue fracture of the femoral stem has been well documented in the literature, particularly involving the high nitrogen stainless steel cemented femoral stems and to a lesser extent the cemented cobalt chrome and uncemented femoral stems. In all cases excessive patient weight leading to increased cantilever bending of the femoral stem was thought to be a major factor contributing to the failure mechanism. From the current literature there is clearly an association between excessive patient weight and fatigue failure of the femoral stem. We suggest avoiding, where possible, the insertion of small stems (particularly cemented stems) and large offset stems (particularly those with a modular neck) in overweight patients.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 30 - 30
1 Dec 2014
Nortje M Hussey D McLennan-Smith R Dymond I Grobler G Dower B Bragdon C Muratoglu O Malchau H
Full Access

Introduction:

The ASR™ Articular Surface Replacement and ASR™ XL Metal-on-Metal systems were recalled due to high revision rates at five years. A worldwide clinical follow-up of patients was initiated. This paper summarizes current findings in South Africa (SA) in comparison with those outside SA (OSA).

Methods:

Patients were followed annually, or until revision, from 10 clinical centers worldwide. Data collected includes demographic, surgical, radiographic, blood metal ion levels, and patient reported outcome measures (PROM).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 62 - 62
1 Aug 2013
McLennan-Smith R
Full Access

It is estimated that 15 % of the population is allergic to metal, most commonly to Nickel, which is a common component of the alloys in most knee and hip arthroplasties. It would therefore be expected that allergy to metal is a frequent form of implant failure – but very little is reported in the literature. With the recent concerns about metal-on-metal bearings and metal ion issues, there has been renewed interest in metal allergy – with the Australian Joint Registry 2010 reporting it as a causative factor in 7 % of Hip Resurfacing revisions.

With over 200 BHR and 571 ASR Hip Resurfacing arthroplasties in my series from 2001, I have identified only 1 patient with implant failure due to metal allergy.

In 2010 two Total Knee Arthroplasty patients presented with pain and strongly positive Melisa allergy tests – these patients were revised to Titanium coated implants resulting in a complete relief of symptoms.

This paper will analyse the problem of metal sensitivity, the investigation and management of the allergic patient who has, or requires, joint arthroplasty


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 122 - 122
1 Jan 2013
Venkatesan M Uzoigwe C Middleton R Young P Burnand H Smith R
Full Access

Background and Purpose

Serum lactate has been shown to be an indicator of adverse clinical outcomes in patients admitted secondary to general trauma or sepsis. We retrospectively investigated whether admission serum venous lactate can predict in-hospital mortality in patients with hip fractures.

Method and Results

Over a 38-month period the admission venous lactate of 807 patients with hip fractures was collated. Mean age was 82 years. The overall in-hospital mortality for this cohort was 9.4%. Mortality was not influenced by the fracture pattern or the type of surgery - be it internal fixation or arthroplasty (p = 0.7). A critical threshold of 3 mmol/L with respect to the influence of venous lactate level on mortality was identified. Mortality rate in those with a lactate level of less than 3 mmol/L was 8.6% and 14.2% for those whose level was 3 mmol/L or greater. A 1 mmol/L increase in venous lactate was associated with a 1.2 (1.02–1.41) increased risk of in-hospital mortality. Patients with a venous lactate of 3 mmol/L or higher had twice the odds of death in hospital compared to matched individuals. There was no statistically significant difference in ASA distribution between those with a lactate of less than or greater than 3 mmol/L.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 16 - 16
1 Sep 2012
Smith R Wood A Keenan A Sabnis B Walmsley P Brenkel I
Full Access

The risk of venous thrombo-embolism (VTE) is high in orthopedics. Oral direct factor Xa inhibitors have been introduced to help reduce the incidence of VTE. To reduce post-operative bleeding antifibrinolytics are used. We aimed to ascertain the effect of two drugs on post operative bleeding and transfusion requirements.

We prospectively recorded patient demographics, operative details, complications, transfusion incidence and VTE incidence in TKR patients. We also sent out questionnaires to patients asking about wound bleeding and VTE. All patients were given 10mg Rivaroxaban 8 hours post operatively and then OD for 14 or 35 days. Patients given tranexamic acid were given 500mg IV, 5 minutes prior to wound closure at the discretion of the surgeon. VTE was Deep Vein Thrombus or Pulmonary Embolism confirmed by Doppler or CTPA. Minor bleed was categorized as dressing soakage or reported wound leakage, major bleed as hematoma requiring revision within 30 days.

509 patients underwent TKR: 200 (39%) received Rivaroxaban only (Group 1), 296 (58%) also received tranexamic acid (Group 2). 13 (3%) patients had no data available. Five patients had a VTE: 4 (2%) in Group 1, 1 (0.3%) in Group 2 [P<0.05]. 39 patients had a minor bleed: 17 (8.5%) in Group 1, 22 (7.4%) in Group 2 [P=0.5]. 2 patients had major bleeds: 1(0.5%) in Group 1 and 1(0.33%) in Group 2 [P=0.69]. There were 30 blood transfusions: 21 (10.5%) in Group 1, 9 (3%) in Group 2 [P<0.0001].

We have demonstrated a reduced requirement for blood transfusions in the tranexamic acid group. However our results, whilst they show a trend towards decreased minor and major bleeding rates, are not significant and require larger studies looking at wound bleeding and leakage.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 32 - 32
1 Jul 2012
Wood A Smith R Keenan A Sabnis B Walmsley P Brenkel I
Full Access

The risk of venous thrombo-embolism (VTE) is high in orthopaedics. Oral direct factor Xa inhibitors have been introduced to help reduce the incidence of VTE. To reduce post-operative bleeding antifibrinolytics are used. We aimed to ascertain the effect of two drugs on post-operative bleeding and transfusion requirements.

We prospectively recorded patient demographics, operative details, complications, transfusion incidence and VTE incidence in TKR patients. We also sent out a questionnaire to patients asking about wound bleeding and VTE. All patients were given 10mg Rivaroxaban 8 hours post operatively and then once a day for 14 days. Patients given tranexamic acid were given 500mg IV, 5 minutes prior to wound closure at the discretion of the surgeon. VTE was confirmed by Doppler or CTPA as Deep Vein Thrombus or Pulmonary Embolism. Minor bleed was categorised as dressing soakage or reported wound leakage, major bleed as haematoma requiring revision within 30 days.

509 patients underwent TKR: 200(39%) only received Rivaroxaban (Group 1), 296(58%) also received tranexamic acid (Group 2). 13(3%) of patients had no data available. 5 patients had a VTE: 4 (2%) Group 1, 1 (0.3%) Group 2 (P<0.05). 39 patients had a minor bleed: 17 (8.5%) Group 1, 22 (7.4%) Group 2 (P=0.5). 2 patients had major bleeds: 1 (0.5%) Group 1, 1 (0.33%) Group 2 (P=0.69). Blood transfusions 21: (10.5%)Group 1, 9 (3%) Group 2 (P<0.0001).

We have demonstrated a reduced requirement for blood transfusions in the tranexamic acid group. However our results whilst they show a trend towards decrease bleeding rates in both the minor and major bleeds are not significant, requiring larger studies looking at wound bleeding and leakage.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 8 - 8
1 Mar 2012
Cobb A Isaac G McLennan-Smith R Oakeshott R Siebel T
Full Access

Introduction

A metal ion study was undertaken in patients who had received an articular surface replacement. The design of these components is optimised in line with lubrication theory and produces low levels of wear in hip joint simulators.

Methods

Patients were recruited in four centres. Whole blood samples were analysed for metal ion levels using high resolution ICP-MS (inductively coupled plasma mass spectrophotometry). A total of 75 patients was enrolled into the study and 65 and 47 patients were assessed after 12 and 24 months implantation respectively. Results are included irrespective of clinical outcome.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 132 - 132
1 Feb 2012
Smith R Wood P
Full Access

We aim to assess the outcome of ankle arthrodesis performed for painful osteoarthritis in the presence of a coronal plane deformity of 20 degrees or more.

To our knowledge this is the first reported series of such a cohort of patients. We have a consecutive and complete series of 24 patients with 26 ankle arthrodeses which were all performed for painful osteoarthritis in the presence of large coronal plane deformity. These patients have a minimum of twelve months clinical follow-up. The results showed a low non-union rate of 8% (2 ankles). These have subsequently been re-fused satisfactorily, and are excluded from further analysis. The results of the remaining 24 ankles, which united primarily, show that patients were very pleased with the outcome of their surgery. AOFAS scores were used to measure pain and function, both pre-operatively and post-operatively. These scores showed large improvements for both pain and function, and had a high statistical significance (p<0.0001). All patients improved in their walking distance and many patients reduced their need for walking aids. Stair climbing ability was also improved in some patients. It is recognised that an ankle arthrodesis usually relieves pain but does not result in a normal gait and full function.

We feel that the high level of patient satisfaction in this series was due to the combination of deformity correction, restoring a functional foot position, and achieving a painless ankle. Arthroplasty of the ankle is a good procedure for relief of pain and restoration of function. However, in the presence of a large coronal plane deformity, ankle arthroplasty is known to fare badly with early failure. Therefore for patients with painful osteoarthritis and a coronal plane deformity of 20 degrees or more, we recommend ankle arthrodesis as the procedure of choice.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 63 - 63
1 Feb 2012
Crawford R Crawford J Carey-Smith R Hilton J
Full Access

Surgery for degenerative lumbar spondylolisthesis may entail both decompression and fusion. The knee-chest position facilitates the decompression, but fixation in this position risks fusion in kyphosis. This can be avoided by intra-operative re-positioning to the prone position. The aim of this study was to quantify the restoration of lordosis achieved by intra-operative repositioning and to assess the clinical and radiological outcome.

A total of forty consecutive patients with degenerative lumbar spondylolisthesis and stenosis were treated by posterior decompression and interbody fusion with pedicle screw fixation. The screw insertion, decompression and interbody grafting were performed with the patient in the knee-chest position. The patient was then re-positioned to the fully prone position for fusion. Sagittal plane angles were measured pre-, intra- and post-operatively. Clinical assessment was performed using SF-36 scores and visual analogue scores for back and leg pain.

The sagittal plane angle increased from median 16.0 degrees pre-operatively to 23.1 degrees post-operatively (p<0.01) and this was maintained at the last follow-up (mean 21 months). The SF-36 scores improved for 7 out of 8 domains and the physical score improved from 29% to 40% (p<0.05). The mean pain scores improved significantly from 7.5 to 3.8 for back pain and from 7.6 to 3.7 for leg pain (p<0.001).

Lumbar spondylolisthesis was found to be associated with a reduction of normal lumbar lordosis and the knee-chest position exacerbates this loss of lordosis. Intra-operative repositioning restored lordosis to greater than the pre-operative angle and was associated with a good clinical outcome.