header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 287 - 287
1 Dec 2013
Puthumanapully PK Shearwood-Porter N Stewart M Kowalski R Browne M Dickinson A
Full Access

Introduction

Implant-cement debonding at the knee has been reported previously [1]. The strength of the mechanical interlock of bone cement on to an implant surface can be associated with both bone cement and implant related factors. In addition to implant surface profile, sub-optimal mixing temperatures and waiting times prior to cement application may weaken the strength of the interlock.

Aims

The study aimed to investigate the influence of bone cement related factors such as mixing temperature, viscosity, and the mixing and waiting times prior to application, in combination with implant surface roughness, on the tensile strength at the interface.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 36 - 36
1 Dec 2013
Cook R Shearwood-Porter N Nicolae C Bolland B Latham J Wood R
Full Access

Introduction:

Cemented femoral components have been used in hip replacement surgery since its inception. For many patients this works well, but recent retrieval studies1–4 and more fundamental studies5, 6 have highlighted the issues of damage and material loss from the both matt and polished cemented stems.

Materials and methods:

This study will focus on a cohort of retrievals from the Southampton Orthopaedics Centre for Arthroplasty Retrieval Surgery (SOCARS). The cohort consisted of a number of hybrid modular total hip replacements with cemented femoral components, both from mixed and matched manufacturer stem and head combinations. Femoral stems were polished, collarless, tapered designs; head sizes ranged from 28–54 mm. For each femoral stem, samples of Palacos R + G cement (Heraeus Medical GmbH, Hanau, Germany) were retrieved from the proximal region of the cement mantle (Gruen zones 1 and 7), corresponding to both macroscopically damaged and undamaged surfaces of the stem. The areas of damage were determined using calibrated digital photography; damaged surfaces were then imaged in detail using an Alicona InfiniteFocus microscope (Alicona Imaging GmbH, Graz, Austria). The technique uses optical microscopy and focus variation technology to extract 3D morphology and depth information from the surface with a resolution of 10 nm. A series of measurements were made and two different analysis routes were used to provide volumetric material loss measurements from the stem surface. High-resolution microscopy and elemental analysis of the cement and stem surfaces was conducted via SEM and EDX to identify the mechanisms leading to material loss at the cement-stem interface.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 914 - 920
1 Jul 2011
Rogers BA Middleton FR Shearwood-Porter N Kinch S Roques A Bradley NW Browne M

Two-stage revision surgery for infected total knee replacement offers the highest rate of success for the elimination of infection. The use of articulating antibiotic-laden cement spacers during the first stage to eradicate infection also allows protection of the soft tissues against excessive scarring and stiffness. We have investigated the effect of cyclical loading of cement spacers on the elution of antibiotics. Femoral and tibial spacers containing vancomycin at a constant concentration and tobramycin of varying concentrations were studied in vitro. The specimens were immersed and loaded cyclically to 250 N, with a flexion excursion of 45°, for 35 000 cycles. The buffered solution was sampled at set intervals and the antibiotic concentration was established so that the elution could be calculated. Unloaded samples were used as a control group for statistical comparison.

The elution of tobramycin increased proportionately with its concentration in cement and was significantly higher at all sampling times from five minutes to 1680 minutes in loaded components compared with the control group (p = 0.021 and p = 0.003, respectively). A similar trend was observed with elution of vancomycin, but this failed to reach statistical significance at five, 1320 and 1560 minutes (p = 0.0508, p = 0.067 and p = 0.347, respectively). However, cyclically loaded and control components showed an increased elution of vancomycin with increasing tobramycin concentration in the specimens, despite all components having the same vancomycin concentration. The concentration of tobramycin influences both tobramycin and vancomycin elution from bone cement. Cyclical loading of the cement spacers enhanced the elution of vancomycin and tobramycin.