Vol. 91-B, Issue SUPP_III | Pages 477 - 477
1 Sep 2009
Wardlaw D Bastian L Van Meirhaeghe J Ranstam J Cummings SR Eastell R Shabe P Tillman JB Boonen S
Full Access

Background: Balloon kyphoplasty is a minimally invasive treatment for acute vertebral fractures that aims to reduce and correct vertebral deformity by inserting expandable balloon tamps and then stabilize the body by filling it with bone cement. The effect of balloon kyphoplasty on quality of life has not been tested in a randomized trial.

Methods: Patients with up to 3 non-traumatic acute vertebral compression fractures were enrolled within 3 months of diagnosis and randomly assigned to receive either balloon kyphoplasty (N=149) or usual nonsurgical care (N=151). Measurements of quality of life, back pain and function, and days of disability and bed rest and spine radiographs were assessed through 12 months of follow-up.

Results: Compared with those assigned to nonsurgical care, participants assigned to balloon kyphoplasty had 5.2 points (95% CI, 2.9 to 7.4; p< 0.0001) greater improvement in the physical component of the SF-36 quality of life questionnaire at one month and 1.5 points (95% CI, − 0.8 to 3.8; p=0.2) at twelve months. Those in the balloon kyphoplasty group also had greater improvement in quality of life by the EuroQol questionnaire at one (0.18 points; 95% CI, 0.08 to 0.28; p=0.0003) and twelve months (0.12 points; 95% CI, 0.01 to 0.22; p=0.025) and improved disability by the Roland-Morris scale at one month (4.0 points; 95% CI, 2.6 to 5.5; p< 0.0001) and twelve months (2.6 points; 95% CI, 1.0 to 4.1; p=0.0012). Balloon kyphoplasty patients had less back pain on a 0 to 10-point numeric rating scale at seven days (2.2 points; 95% CI, 1.6 to 2.8; p< 0.0001) and twelve months (0.9 points; 95% CI, 0.3 to 1.5; p=0.0034) and reported fewer days of limited activity at one month (2.9 days per 2 weeks; 95% CI, 1.3 to 4.6; p=0.0004) and twelve months (1.6; 95% CI, − 0.1 to 3.3; p=0.068). Fewer patients assigned to balloon kyphoplasty took pain medications or used walking aids during follow-up. There was no significant difference in the number of patients with adverse events or serious adverse events in the kyphoplasty and nonsurgical groups. New radiographically detected vertebral fractures occurred in 41.8% of subjects in the balloon kyphoplasty and 37.8% in the nonsurgical group (4% difference; 95% CI − 7.5 to 15.6; p=0.5) and were not statistically different.

Conclusion: Compared to nonsurgical treatment, balloon kyphoplasty safely improved quality of life and reduced back pain, disability and the use of pain medications and walking aids. Significant improvements in multiple measurements of quality of life, pain and disability continue for at least 1 year. Balloon kyphoplasty did not increase adverse events including the risk of vertebral fractures (Clinicaltrials.gov number, NCT00211211).