Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 253 - 253
1 Jul 2014
Melli V Rondelli G Sandrini E Altomare L Bolelli G Bonferroni B Lusvarghi L Chiesa R De Nardo L
Full Access

Summary

Metal Injection Molding could provide cost saving of about 20–50% for implantable medical device manufacturing and hence healthcare public spending. Corrosion behaviour and biocompatibility of the new manufactured alloy were studied and showed similar behaviour compared to the traditional one.

Introduction

The growing trend for total joint arthroplasties could raise healthcare costs in the near future. Metal Injection Molding (MIM) is a near net shape manufacturing technology and allows the production of finite prosthesis components saving the machining step, and so resources, up to 20–50%. In order to apply such process to the production of actual devices, the bulk material have to show biocompatibility and corrosion behaviour similar to the traditional one. (ASTM F2083, ISO 21536) The aim of this work was to compare cast and forged CoCrMo alloy with the MIM one from the electrochemical point of view and cytocompatibility.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 266 - 266
1 May 2009
Simoncini M Sandrini E Cigada A Castoldi F Marmotti A Rossi R Rossi P
Full Access

Aims: Hydroxyapatite coatings have been proven to improve the osteointegration of metal implants however they are not stable and they might delaminate from the metal surface when challenged by the mechanical stresses experienced by the implant. Therefore, efforts of different researchers are being devoted to find more stable coatings or surface treatments that could replace HA.

In particular, spontaneous calcium phosphate deposition on titanium surfaces from aqueous electrolyte containing calcium and phosphate ions, such as simulated body fluid solutions, has been observed and is believed to be related to the excellent bonding capability in contact with bone tissue.

In the present study, a new multiphase anodic spark deposition (ASD) method combined with chemical etching is presented It has been optimized and such modified titanium surface exhibited high mineralisation potential, selective protein adsorption, quicker and more intensive osteoblasts adhesion and differentiation. Such treatements was labelled BioSpark™ and consisted in a thick calcium-phosphate-doped oxide film growth on the titanium bulk. This oxide layer exhibits anatase lattice, micro-porosity and a thin nano-roughened texture.

Methods: The effect of this process, was investigated invitro and in vivo in cortical and spongy bone of 12 adult sheep. Histomorphometric and microhardness measurement were carried out at each experimental time (4, 8, 12 weeks) to quantify the bone-to-implant contact around the implants, the bone ingrowth as well as the newly bone hardness and bone maturation index

Results: Data suggests that the BioSpark treatment produces a modification of the Ti surface, which represents good bioactivity and may be suitable for achieving a stable implant osseointegration.

Conclusions: Such surface modification treatments was applied in the last two years on dental implants with great success and is now being tested in human being for histological studies. In the future, it will be applied on orthopaedic prostheses devices in order to improve device osteintegration. The data demonstrate that this type of surface improves the material osteointegration potential when compared to conventional surfaces while offering high mechanical stability.