header advert
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 240 - 248
1 Mar 2024
Kim SE Kwak J Ro DH Lee MC Han H

Aims

The aim of this study was to evaluate whether achieving medial joint opening, as measured by the change in the joint line convergence angle (∆JLCA), is a better predictor of clinical outcomes after high tibial osteotomy (HTO) compared with the mechanical axis deviation, and to find individualized targets for the redistribution of load that reflect bony alignment, joint laxity, and surgical technique.

Methods

This retrospective study analyzed 121 knees in 101 patients. Patient-reported outcome measures (PROMs) were collected preoperatively and one year postoperatively, and were analyzed according to the surgical technique (opening or closing wedge), postoperative mechanical axis deviation (deviations above and below 10% from the target), and achievement of medial joint opening (∆JLCA > 1°). Radiological parameters, including JLCA, mechanical axis deviation, and the difference in JLCA between preoperative standing and supine radiographs (JLCAPD), an indicator of medial soft-tissue laxity, were measured. Cut-off points for parameters related to achieving medial joint opening were calculated from receiver operating characteristic (ROC) curves.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 146 - 146
1 Jan 2016
Lee MC Lee S Park IW Ro DH Kim KB Chung KY Seong SC
Full Access

Purpose

Although the use of stems in revision total knee arthroplasty (RTKA) enhances survival by improving the stability of implant, questions as to the optimal fixation method as well as the vertical extent of the cement, remain unanswered. This study aimed 1) to determine the correlation between the vertical extent of cement and implant loosening; and 2) to determine the minimum cementing extent for a stable implant in revision TKA with a hybrid technique.

Materials and Methods

We retrospectively analyzed 109 stemmed RTKAs with average follow-up of 63 months. In each case, a single varus-valgus constrained implant was used and fixed with a hybrid technique. During surgery, stem was partially covered with cement beyond stem-implant junction. Stability of implant was evaluated according to the modified Knee Society Radiographic Scoring System. Cementing extent was defined as length from implant base to the end of the radiopaque line around the stem. The correlation between the vertical cementing extent and implant stability was analyzed, and the minimal vertical cementing extent for a stable implant was evaluated with a scatter plot.