header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 72 - 72
1 Dec 2018
Govaert G Bosch P IJpma F Glauche J Jutte P Lemans J Wendt K Reininga I Glaudemans A
Full Access

Aim

White blood cell (WBC) scintigraphy for diagnosing fracture-related infections (FRIs) has only been investigated in small patient series. Aims of this study were (1) to establish the accuracy of WBC scintigraphy for diagnosing FRIs, and (2) to investigate whether the duration of the time interval between surgery and WBC scintigraphy influences its accuracy.

Method

192 consecutive WBC scintigraphies with 99mTc-HMPAO-labelled autologous leucocytes performed for suspected peripheral FRI were included. The goldstandard was based on the outcome of microbiological investigation in case of surgery, or - when these were not available - on clinical follow-up of at least six months. The discriminative ability of the imaging modalities was quantified by several measures of diagnostic accuracy. A multivariable logistic regression analysis was performed to identify predictive variables of a false-positive or false-negative WBC scintigraphy test result.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 20 - 20
1 Apr 2017
Meijer M Boerboom A Stevens M Reininga I Janssen D Verdonschot N
Full Access

Background

Trabecular metal (TM) cones are designed to fill up major bone defects in total knee arthroplasty. Tibial components can be implanted in combination with a stem, but it is unclear if this is necessary after reconstruction with a TM cone. Implanting a stem may give extra stability, but may also have negative side-effects. Aim of this study was to investigate stability and strain distribution of a tibial plateau reconstruction with a TM cone while the tibal component is implanted with and without a stem, and whether prosthetic stability was influenced by bone mineral density (BMD).

Methods

Tibial revision arthroplasties were performed after reconstruction of an AORI 2B bone defect with TM cones. Plateaus were implanted in seven pairs of cadaveric tibiae; of each pair, one was implanted with and the other without stem. All specimens were loaded to one bodyweight alternating between the medial and lateral tibia plateau. Implant-bone micro motions, bone strains, BMD and correlations were measured and/or calculated.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 31 - 31
1 Apr 2017
Meijer M Boerboom A Bulstra S Reininga I Stevens M
Full Access

Background

Achieving optimal prosthesis alignment during total knee arthroplasty (TKA) is essential. Imageless computer-assisted surgery (CAS) is developed to improve knee prosthesis alignment and with CAS it is possible to perform intraoperative alignment measurements. Lower limb alignment measurements are also performed for preoperative planning and postoperative evaluation. A new stereoradiography system, called EOS, can be used to perform these measurements in 3D and thus measurement errors due to malpositioning can be eliminated. Since both CAS and EOS are based on 3D modeling, measurements should theoretically correlate well. Therefore, objective was to compare intraoperative CAS-TKA measurements with pre- and postoperative EOS 3D measurements.

Methods

In a prospective study 56 CAS-TKAs were performed and alignment measurements were recorded two times: before bone cuts were made and after implantation of the prosthesis. Pre- and postoperative coronal alignment measurements were performed using EOS 3D. CAS measurements were compared with EOS 3D reconstructions. Measured angles were: varus/valgus (VV), mechanical lateral distal-femoral (mLDFA) and medial proximal tibial angle (mMPTA).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 141 - 141
1 Jul 2014
Meijer M Boerboom A Stevens M Bulstra S Reininga I
Full Access

Summary

The EOS stereography system has been developed for the evaluation of prosthetic alignment. This new low-dose device provides reliable 2D/3D measurements of knee prosthesis alignment.

Introduction

Achieving optimal prosthetic alignment during Total Knee Arthroplasty (TKA) is an essential part of the surgical procedure since malpositioning can lead to early loosening of the prosthesis and eventually revision surgery. Conventional weight-bearing radiographs are part of the usual clinical follow-up after both primary TKA and revision TKA (rTKA), to assess alignment in the coronal and sagittal planes. However, proportions and angles may not be correct on radiographs since divergence exists in the vertical and horizontal planes. Furthermore estimating the exact planes by looking at the position of the patella depends on rotation in the hip joint and this may be misinterpreted by the investigator. A computed tomography (CT) scanogram can also be used. However, due to high levels of radiation and costs it is not routinely used. To this end, a new device, the EOS stereography system, has been developed. With this biplanar low-dose X-ray technique, orthogonally made 2D images and 3D reconstructions can be obtained. Advantages of EOS are that images of the leg are obtained on a 1:1 scale with an amount of radiation 800–1000 times lower than CT-scans and 10 times lower than conventional radiographs. Another advantage is that the 3D reconstructions lead to determination of the real coronal and sagittal planes. However, the software for creating 3D reconstructions is developed for the lower limbs without knee prosthesis material. Consequently a reliability study concerning the generation of 2D images and 3D reconstructions of a leg containing a knee prosthesis has not been performed yet. Therefore objective of this study was to investigate interobserver and intraobserver reliability of knee prosthetic alignment measurements after rTKA using EOS.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 55 - 55
1 Jul 2014
Meijer M Boerboom A Stevens M Bulstra S Reininga I
Full Access

Summary

Computer assisted surgery (CAS) during total knee arthroplasty (TKA) is known to improve prosthetic alignment in coronal and sagittal plane. In this systematic review, no evidence is found that CAS also improves axial component orientation when used during TKA.

Introduction

Primary total knee arthroplasty (TKA) is a safe and cost-effective treatment for end-stage knee osteoarthritis. Correct prosthesis alignment is essential, since malpositioning of the prosthesis leads to worse functional outcome and increased wear, which compromises survival of the prosthesis. Computer assisted surgery (CAS) has been developed to enhance prosthesis alignment during TKA. CAS significantly improves postoperative coronal and sagittal alignment compared to conventional TKA. However, the influence of CAS on rotational alignment is a matter of debate. Therefore purpose of this review is to assess published evidence on the influence of CAS during TKA on postoperative rotational alignment.