Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 473 - 473
1 Sep 2012
Kotwal R Rath N Paringe V Lyons K Thomas R
Full Access

Introduction

The assessment of the accuracy of reduction of the ankle syndesmosis has traditionally been made using plain radiographic measurements. Recent studies have shown that computerized tomography (CT) scan is more sensitive than radiographs in detecting diastasis. The ethos has now therefore shifted towards CT scan assessment of the syndesmosis. There is however no validated method to scan the syndesmosis and measure it on the CT scans. This exposes the patient to significant radiation risk and also to anxiety from inappropriate interpretation from these scans.

The objectives of this research project are to investigate the current practice of CT scanning the syndesmosis at a University Hospital and to devise a new CT protocol to reduce radiation exposure to patients and to assist surgeons in interpreting the observations.

Methods

Research Ethics Committee approval was obtained. Current practice was evaluated. A new 5 cut CT protocol was devised. Starting at the level of the distal tibial plafond, 5 cuts were made proximally 0.5 cm apart. Accuracy of the syndesmosis reduction was assessed just above the distal tibial plafond. Both the injured and the normal sides were scanned 12 weeks post surgery. The normal side served as a control.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 48 - 48
1 Jul 2012
Davies HG Dudhniwala AG Rath N White S
Full Access

Objective

Assess patient compliance with self-administration of subcutaneous low-molecular-weight-heparin (enoxaparin) injections for 14 days following knee replacement surgery.

Methods

Consecutive patients undergoing knee replacement surgery during a 4-month period were identified from a database. All patients had been taught to self administer enoxaparin injections during their in patient stay and asked to self administer the remaining injections after discharge if feasible. Patients were then sent questionnaires designed to assess compliance.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 17 - 17
1 Jul 2012
Rath N Bewick A Williams R Wilson C White S Forster M
Full Access

Background

Patellofemoral replacement is an established intervention in selected patients with severe isolated patellofemoral osteoarthritis. FPV (Wright Medical, UK) is a third generation patellofemoral arthroplasty implant and is the second most used after AVON in National Joint Registry for England and Wales. Reports of survivorship and functional of this implant are scarce in literature.

Aim

Evaluation of functional outcome and survivorship following FPV patellofemoral arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 43 - 43
1 May 2012
Kotwal R Paringe V Rath N Lyons K
Full Access

Injury to the syndesmosis occurs in approximately 10% of all patients with ankle fractures. Anatomic restoration of the syndesmosis is the only significant predictor of functional outcome. Several techniques of syndesmosis fixation are currently used such as cortical screws, bioabsorbable screws and more recently introduced suture-button fixation. No single technique has been shown to be superior to the others.

The objective of this research project is to investigate whether treatment with a tightrope (suture-button fixation) gives superior results than the use of a cortical screw in the treatment of acute syndesmotic ankle injuries with regards to function, pain, satisfaction and return to normal activities.

Research Ethics Committee approval was obtained. 40 patients with syndesmotic ankle injuries associated with diastasis were prospectively recruited, 20 in each group. Patients were randomized to one of the 2 groups. At 12 weeks, American Orthopaedic Foot and Ankle Society (AOFAS) scores and a computerized tomography (CT) scan of both the ankles was obtained. At 1 year, AOFAS scores and satisfaction was assessed.

32 patients have been recruited so far, 20 in the tightrope group and 12 in the cortical screw group. Mean AOFAS scores at 3 months post-op were 90.67 in the Tightrope group and 84 in the screw group. The difference was not significant (p= 0.096). CT scans revealed that the quality of syndesmosis reduction was equally good with both the techniques. Metalwork prominence was common with both the devices.

Discussion and Conclusion

Both the devices achieved good reduction of the syndesmosis. Our CT scan protocol has insignificant radiation risk and allows more accurate assessment of the syndesmosis. Early clinical results do not show a significant difference in the functional outcome with the use of either device. Long-term (1 year) follow-up has been planned.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 147 - 147
1 May 2011
Rath N Guha A Khurana A Hemmadi S Thomas R Odoherty D
Full Access

We audited all patients who underwent Foot and Ankle surgery at the University Hospital of Wales over one financial year (April 2007 – March 2008).

Patients were identified from the hospital OPCS-4 coding system and all scheduled and unscheduled visits to hospital investigated. Both trauma and elective patients were included. Patients were followed up for a mean period of 9 months (Range 1–14 months) following surgery.

The records for 1052 patients were evaluated. Of these, 77% were elective cases and 23% were trauma related. Overall about 10 % of our foot and ankle patients (100/1052) either attended the A& E Department or had an unplanned clinic visit at some stage of their follow up. Three quarters of these patients were admitted to hospital (median stay 1 day, range 1–51 days).

Twenty five patients (24 A& E; 1 medical) simply re-attended, but were not admitted. The majority of these (58%) had plaster-related problems (8\24) or superficial wound infections (6/24). The remaining patients presented with pain around the operated area, and were discharged after investigation. One patient presented to the physicians 44 days after excision of a Morton’s neuroma with a DVT.

Seventy five patients (7%) were re-admitted to hospital. Two were admitted under the physicians: one with a pulmonary embolus (30 days post ORIF ankle) and one following a cardiac arrest (20 days post ORIF ankle). Out of the remainder 34 patients had planned removal of metalwork, 9 patients had metalwork removed because of infection and 21 patients had soft-tissue infection requiring antibiotics or debridement. Overall, 9 patients underwent revision surgery (0.85%).

The overall infection and thromboembolic rate was 3.42 %(6 A& E + 30 T& O/1052) and 0.28% (1A& E + 2 medical/1052) respectively.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 125 - 125
1 May 2011
Keerthi N Rath N Mukhopadhya M Pullen H Thomas R
Full Access

Anatomical variation of Lisfranc mortise has been implicated in the susceptibility of Lisfranc fracture-dislocation. We investigated whether the variations in the dimensions of second metatarsal base makes the joint vulnerable to fracture dislocation.

Patients and Methods: 31 normal (group A) and 23 injured (group B) foot x-rays were compared. The average age of patients was 33(range 16–64) years. Routine AP and 45 degree oblique foot x-rays were used to measure second metatarsal parameters such as L (length of second metatarsal) were measured on x-rays in both groups. Additionally D (height of base of second metatarsal in sagittal plane of foot) was measured in CT scans. Statistical analysis was performed to test the viability of the null hypothesis that states that the relationship of second metatarsal length and height at the base does not correlate with increased susceptibility of Lisfranc injury. Similar analyses of the relevant parameters at the second metatarsal mortice were also calculated.

Results: Mean values of D, L and D/L were obtained in both groups. Statistically the value of D/L was found to be significantly different between injured group and normal group, with a P value of 0.03, while the values of length of second metatarsal itself was not significantly different between two groups (P=0.15). However, no significant correlation was noticed using other parameters of the second metatarsal mortice.

Conclusion: Previously shallowness of the second metatarsal mortice was shown to be significantly correlated with increased risk of Lisfranc injury. However, this study suggests that dimensions of second metatarsal such as, depth/length of the second metatarsal significantly increase the risk of Lisfranc injury. In other words more slender metatarsal dimensions at its base carry increased risk to Lisfranc injury. Thus, anatomical variation at the base of the second metatarsal makes the Lisfranc joint susceptible to injury.