Aim

Infection rates after management of open fractures are still high. Existing guidelines regarding prevention of this complication are inhomogeneous. A survey directed to orthopaedic trauma surgeons worldwide aims to give an overview of current practices in the management of open fractures.

Method

An international group of trauma surgeons and infection specialists with experience in the field of musculoskeletal infections developed a questionnaire that was distributed via email to all AOTrauma members worldwide. Descriptive statistical analysis was performed.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 63 - 63
1 Dec 2017
Pützler J Arens D Metsemakers W Zeiter S Richard K Richards G Raschke M Moriarty F
Full Access

Aim

Open fractures still have a high risk for fracture-related Infection (FRI). The optimal duration of perioperative antibiotic prophylaxis (PAP) for open fractures remains controversial due to heterogeneous guidelines and highly variable prophylactic regimens in clinical practice. In order to provide further evidence with which to support the selection of antibiotic duration for open fracture care, we performed a preclinical evaluation in a contaminated rabbit fracture model.

Method

A complete humeral osteotomy in 18 rabbits was fixed with a 7-hole-LCP and inoculated with Staphylococcus aureus (2×106 colony forming units, CFU per inoculum). This inoculum was previously shown to result in a 100% infection rate in the absence of any antibiotic prophylaxis. Cefuroxime was administered intravenously in a weight adjusted dosage equivalent to human medicine (18.75 mg/kg) as a single shot only, for 24 hours (every 8 hours) and for 72 hours (every 8 hours) in separate groups of rabbits (n=6 per group). Infection rate per group was assessed after two weeks by quantitative bacteriological evaluation of soft tissue, bone and implants. Blood samples were taken from rabbits preoperatively and on days 3, 7 and 14 after surgery to measure white blood cell count (WBC) and C-reactive protein (CRP) levels.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 102 - 102
1 Dec 2017
Pützler J Zeiter S Vallejo A Gehweiler D Raschke M Richards G Moriarty F
Full Access

Aim

Treatment regimens for fracture-related infection (FRI) often refer to the classification of Willenegger and Roth, which stratifies FRIs based on time of onset of symptoms. The classification includes early (<2 weeks), delayed (2–10 weeks) and late (>10 weeks) infections. Early infections are generally treated with debridement and systemic antibiotics but may not require implant removal. Delayed and late infections, in contrast, are believed to have a mature biofilm on the implant, and therefore, treatment often involves implant removal. This distinction between early and delayed infections has never been established in a controlled clinical or preclinical study. This study tested the hypothesis that early and delayed FRIs respond differently to treatment comprising implant retention.

Method

A complete humeral osteotomy in 16 rabbits was fixed with a 7-hole-LCP and inoculated with Staphylococcus aureus. The inoculum size (2×106 colony forming units per inoculum) was previously tested without antibiotic intervention to result in infection of all animals persisting for at least 12 weeks.4 The infection was allowed to develop for either 1 (early group) or 4 (delayed group) weeks (n= 8 per group) after bacterial inoculation. At these time points, treatment involved debridement and irrigation of the wound (no implant removal) and quantitative bacteriological evaluation of the removed materials. Systemic antibiotics were administered according to a common clinical regimen (2 weeks: rifampin + nafcillin, followed by 4 weeks: rifampin + levofloxacin). After an additional one-week antibiotic washout period, animals were euthanized and a quantitative bacteriology of soft tissue, implant (after sonication) and bone was performed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 67 - 67
1 Aug 2013
Hofbauer V Bittrich T Glasbrenner J Koesters C Raschke M
Full Access

INTRODUCTION

The medial patellofemoral ligament (MPFL) has been recognised as the most important medial structure preventing lateral dislocation or subluxation of the patella (LeGrand 2007). After MPFL rupture the patella deviates from the optimal path resulting in an altered retropatellar pressure distribution. This may lead to an early degeneration with loss of function and need for endoprosthetic joint replacement. The goal of this study was to obtain first data about retropatellar pressure distribution under simulation of physiological quadriceps muscle loading and evaluate the influence of ligament instabilities.

MATERIALS AND METHOD

On ten fresh-frozen cadaveric knees the quadriceps muscle was divided into 5 parts along their anatomic fiber orientation analogous to Farahmand 1998. Muscular loading was achieved by applying weights to each of the five components in proportion to the cross sectional muscle area (total load 175 N).

A custom made sensor was introduced between the patella and femur [Pliance, Novel / Germany]. The sensor consists of 85 single cells. The robot-control-unit is liked to a force-torque sensor. The force free knee-flexion-path from 0° to 90° was calculated during three “passive path” measurements. The actual measurements followed with identical parameters.

At first, the retropatellar pressure distribution was recorded with intact ligaments (“native”). After cutting the MPFL the test was repeated. Then double bundle MPFL reconstruction (Schoettle 2009) was performed and the pressure distribution was obtained again. Minimum, mean and maximum pressures and forces were statistically compared in each of the three tested conditions (native Patella with intact MPFL, cut and reconstructed MPFL). We followed the hypothesis that MPFL reconstruction can restore native retropatellar pressure distribution.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 95 - 95
1 Oct 2012
Hofbauer V Bittrich T Glasbrenner J Schulze M Burger M Zantop T Rosenbaum D Ruebberdt A Raschke M
Full Access

The medial patellofemoral ligament (MPFL) has been recognised as the most important medial structure preventing lateral dislocation or subluxation of the patella (LeGrand 2007). After MPFL rupture the patella deviates from the optimal path resulting in an altered retropatellar pressure distribution. This may lead to an early degeneration with loss of function and need for endoprosthetic joint replacement. The goal of this study was to develop a dynamic knee-simulator to test the influence of ligament instabilities to patella-tracking under simulation of physiological quadriceps muscle loading.

On 10 fresh-frozen cadaveric knees the quadriceps muscle was divided into five parts along their anatomic fibre orientation analogous to Farahmand 1998. The muscular loading was achieved by applying weights to each of the fife components in proportion to the cross sectional muscle area. A total of 175 N was connected to the muscles using modified industrial cable connecting systems [Lancier Calbe, Drensteinfurt/Germany].

A novel light digital patellar reference base (DRB) was developed and attached to the patella with four bone screws. On addition a femoral and tibial digital reference base was constructed and secured to these two bones.

Position data of the patella, the femur and tibia was tracked by a conventional tracking system [Optotrak, NDI Europe]. The relative movement between femur and tibia (“flexion path”) and patella and femur (“patella tracking”) was recorded. For retropatellar pressure measurement a custom made sensor was introduced between the patella and femur [Pliance, Novel/Germany]. The sensor consists of 85 single pressure measuring cells. The robot-control-unit is liked to a force-torque sensor (hybrid method). The force free knee-flexion-path from 0° to 90° was calculated during three “passive path” measurements using this hybrid robotic method. The actual measurements followed with identical parameters.

The 3D-patella position was recorded (six degrees of freedom) along with the corresponding retropatellar pressure distribution according to knee-flexion and medial forces (intact vs. cut MPFL). Measurements were performed for the intact knee (“native”), with muscular quadriceps loading, after opening the joint capsule and with introduced pressure sensor to differentiate each of their influences.

The load free knee-flexion-path (“passive path”) could be calculated for all of the ten knees and was utilised as the basis for all dynamic measurements. There was no alteration of the “flexion-path”. Thus the measurements were only influenced by the variables “capsular joint opening,” “muscular quadriceps loading” and “MPFL-tension”.

The custom made connections between the five quadriceps components and weights proved to be a secure way to prevent rupture due to the applied forces of up to 70 N during the average measuring time of 7.5 h/knee. Only on one knee the Vastus lateralis obliquus muscle ruptured proximally. All reference bases were 100% visible despite the knee flexion form 0°–90°. No loosening of the reference base screws occurred.

Overall the combination of a robotic-assisted, force free dynamic knee-flexion under quadriceps simulation and 3D-patella-tracking seems to be a promising method to evaluate the biomechanical influences of ligaments on the human knee.