Traditional radiographic criteria might underestimate or fail to detect subtle types of acetabular dysplasia. Acetabular sector angles (ASA) can measure the degree of anterior and posterior coverage of the femoral head on computed tomography (CT). This study aims to determine ASA values at different axial levels in a cohort of (1) asymptomatic, high-functioning hips without underlying hip pathology (controls); and (2) symptomatic, dysplastic hips that underwent periacetabular osteotomy (PAO). Thereby, we aimed to define CT-based thresholds for hip dysplasia and its subtypes.

This is an IRB approved cross-sectional study of 51 high functioning, asymptomatic patients (102 hips) (Oxford Hip Score >43), without signs of osteoarthritis (Tönnis grade≤1), who underwent a CT scan of the pelvis (mean age: 52.1±5.5 years; 52.9% females); and 66 patients (72 hips) with symptomatic hip dysplasia treated with peri-acetabular osteotomy (PAO) (mean age: 29.3±7.3 years; 85.9% females). Anterior and posterior acetabular sector angles (AASA & PASA) were measured by two observers at three CT axial levels to determine equatorial, intermediate, and proximal ASA. Inter- and intra-observer reliability coefficient was high (between 0.882–0.992). Cut-off values for acetabular deficiency were determined based on Receiver Operating Characteristic (ROC) curve analysis, area under the curve (AUC) was calculated.

The dysplastic group had significantly smaller ASAs compared to the Control Group, AUC was the highest at the proximal and intermediate PASA. Controls had a mean proximal PASA of 162°±17°, with a cut-off value for dysplasia of 137° (AUC: 0.908). At the intermediate level, the mean PASA of controls was 117°±11°, with a cut-off value of 107° (AUC 0.904). Cut-off for anterior dysplasia was 133° for proximal AASA (AUC 0.859) and 57° for equatorial AASA (AUC 0.868). Cut-off for posterior dysplasia was 102° for intermediate PASA (AUC 0.933).

Measurement of ASA on CT is a reliable tool to identify dysplastic hips with high diagnostic accuracy. Posterior ASA less than 137° at the proximal level, and 107° at the intermediate level should alert clinicians of the presence of dysplasia.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 1 - 1
1 May 2018
Grammatopoulos G Speirs A Ng G Riviere C Rakhra K Lamontagne M Beaule PE
Full Access

Introduction

Acetabular and spino-pelvic (SP) morphological parameters are important determinants of hip joint dynamics. This study aims to determine whether acetabular and SP morphological differences exist between hips with and without cam morphology and between symptomatic and asymptomatic hips with cam morphology.

Patients/Materials & Methods

A prospective cohort of 67 patients/hips was studied. Hips were either asymptomatic with no cam (Controls, n=18), symptomatic with cam (n=26) or asymptomatic with cam (n=23). CT-based quantitative assessments of femoral, acetabular, pelvic and spino-pelvic parameters were performed. Measurements were compared between controls and those with a cam deformity, as well as between the 3 groups. Morphological parameters that were independent predictors of a symptomatic Cam were determined using a regression analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 25 - 25
1 May 2018
Grammatopoulos G Jamieson P Dobransky J Rakhra K Carsen S Beaule P
Full Access

Introduction

This study aims to determine how the acetabular version changes during the key developmental stage of adolescence, and what contributes to this change. In addition, we examined whether patient factors (BMI, activity levels) or the femoral-sided anatomy contribute to any observed changes.

Patients/Materials & Methods

This prospective longitudinal cohort study included 19 volunteers (38 healthy hips). The participants underwent clinical examination (BMI, range of movement assessment), MRIs of both hips at recruitment and at follow-up (6 ± 2 years) and HSS Paediatric Functional Activity Brief Scale (Pedi-FABS) questionnaire. MRI scans were assessed at both time points to determine change of the tri-radiate cartilage complex (TCC), the acetabular anteversion, the degree of anterior, posterior, and superior femoral head coverage by the acetabulum, and anterior and antero-superior alpha angles. We investigated if the change in anteversion and sector angles was influenced by the BMI, range of movement measurements, the Pedi-FABS or the alpha angle measurements.