header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 39 - 39
1 May 2017
Gee C Poole W Wilson D Gibbs J Stott P
Full Access

Adverse reaction to metal debris (ARMD) is well recognised as a complication of large head metal on metal total hip replacement (THR) leading to pain, bone and tissue loss and the need for revision surgery. An emerging problem of trunnionosis in metal on polyethylene total hip replacements leading to ARMD has been reported in a few cases. Increased metal ion levels have been reported in THR's with a titanium stem and a cobalt chrome head such as the Accolade-Trident THR (Stryker).

We present 3 cases of ARMD with Accloade-Trident THR's with 36mm cobalt chrome head and a polyethylene liner. Metal ion levels were elevated in all three patients (cobalt 10.3 – 161nmol/l). Intraoperative tissue samples were negative for infection and inflammatory markers were normal. Abnormal fluid collections were seen in all three cases and bone loss was severe in one patient leading to a proximal femoral replacement. Histology demonstrated either a non-specific inflammatory reaction in a case which presented early or a granulomatous reaction in a more advanced case suggesting a local foreign body reaction. All patients had improved symptoms post-operatively. 1 patient who had staged bilateral Accolade-Trident THR's required revision of both THR's.

ARMD in metal on polyethylene THR's with a titanium stem represents a potential emerging problem. Further studies are required to assess whether these occurrences are rare or represent the tip of an iceberg.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 15 - 15
1 Jun 2015
Poole W Guthrie H Wilson D Freeman R Bellringer S Guryel E Nicol S
Full Access

Distal femoral fracture fixation has historically been associated with high rates of reoperation because of mal-union, non-union and implant failure. We hypothesised that recent advances in distal femoral locking plate design and material along with an improved understanding of biomechanical principles would improve outcome. In a 5-year retrospective study utilising electronic patient records and serial radiographs (including recall by letter where there was no radiological evidence of union) we identified a series of 129 distal femoral fractures treated with modern locking plates in 123 patients. The majority were female (80%), elderly (mean 73 years) and infirm (72/123 ASA 3 or more). A consultant performed the operation in 67% of cases. 49% were followed to radiological union, while 25% died within the follow up period. Reoperation rate for implant failure was 4%, with all failures occurring early (within 5 months). Our follow up correlates with the infirm elderly population concerned. Our cohort shares many similarities with hip fracture patients and we propose that this group should receive equal surgical priority and optimum management also be rewarded by enhanced tariffs. Modern locking plates used in combination with the correct biomechanical principles are performing well in our centre.