Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 530 - 531
1 Nov 2011
Buord J Parratte S Flécher X Pauly V Argenson J
Full Access

Purpose of the study: Three-screw fixation is the classical treatment for true Garden I in the elderly patient. Complication rates have been high in the literature. Furthermore, in this context outcome for arthroplasty after failed osteosynthesis is less satisfactory than first-intention arthroplasty. This is why functional treatment of Garden I fractures of the neck of the femur has been proposed, including rapid return to the upright position and strict radiographic and clinical control. The purpose of this work was to first evaluate the results of this management option for true Garden I fractures in patients aged over 65 years and second to search for factors predictive of secondary displacement.

Material and methods: All patients aged over 65 years and admitted to the unit for true Garden I fractures from January 2005 to December 2006 were included in this prospective study. A functional treatment including early return to the upright position and walking test on day 1 was instituted, followed by radiographic controls on days 2, 7, 14, 21, and 45 then at 3 months and one year. Referral to a rehabilitation centre at discharge on day 5 was scheduled if there was no displacement. In the event of a displacement, arthroplasty was performed. Fifty-seven patients, mean age 82.8±8.5 years (range 65–99) were included. The radiographic and clinical follow-ups were made by an independent observer.

Results: The displacement rate was 29.8%. These patients were treated by arthroplasty. In the group of patients without displacement, at minimum one year follow-up, there has been no need for surgical revision excepting one case of osteonecrosis at one year requiring implantation of a total prosthesis. The mean Parker score in this group was 6.4 and the mean Harris score 83, it was 85 in the arthroplasty group. Among the predictive factors identified at multivariate analysis were: age, gender, side, type of fracture, fracture orientation, degree of valgus or sagittal displacement, general status. Displacement was not statistically predictive.

Discussion: The results of our prospective study show that 70% of patients included were treated successfully without surgery, confirming reports in the literature and justifying utilisation of this management strategy.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 527 - 527
1 Nov 2011
Parratte S Since M Pauly V Aubaniac J Argenson J
Full Access

Purpose of the study: It has been demonstrated that the anatomy of the distal femur differs by gender. The ratio of the mediolateral/anteroposterior distance, the shape of the distal femur, and the orientation of the trochlea differ between males and females. To adapt to these differences, prostheses specifically designed for female patients (TKAgender) were developed. The purpose of our study was to compare the first objective and subjective outcomes with these prostheses.

Material and methods: Thirty women who underwent bilateral surgery within a six month interval for degenerative joint disease of the knee between March 2006 and March 2008 were included in a comparative prospective study. The side receiving the gender implant was determined at random. Operative and postoperative protocols were the same excepting the femoral implant. Patients were not informed of which knee had received the gender prosthesis. Mean age in this series was 67 years and mean BMI 26. All implants were cemented. At minimum one year follow-up, objective and subjective analysis included specific questions concerning preference and quality of life presented by an independent observer.

Results: The Knee Society clinical scores were comparable in the two groups, as were the results for the different items of the KOOS score. For preferences: the patients preferred the gender knee in 75% of the cases (p< 0.01), they reported less noise or cracking sounds in the anterior part of the knee for 68% (p=0.03) and had the impression that the knee recovered faster in 64% (p=0.04).

Discussion: To our knowledge, this is the first report of results concerning implants specifically designed for female patients. At short-term, the only difference in the patients’ preference was a subjective feeling of less impairment for the patellar track. It will be interesting to follow these patients to assess the long-term impact on the patellofemoral articulation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 440 - 440
1 Nov 2011
Parratte S Kilian P Lecorroller T Pauly V Champsaur P Argenson J
Full Access

Most of computer-assisted computer assisted system rely on the peri-operative acquisition of the anterior pelvic plane defined as the plane crossing the two anterior iliac spine and the symphysis. The goal of this study was to evaluate in vivo and in vitro the accuracy of the anterior pelvic plane acquisition, considered as the reference for computer-assisted total hip arthroplasty (THA).

Cup placement was performed using an imageless computer-assisted system in thirty patients during THA. Post-operatively the position of the cup was evaluated on computed tomography using a validated tridimensional software. The differences between the perioperative and postoperative angles for abduction and anteversion were compared using a two-group pair test.

On two cadavers four clinicians performed ten times the anterior pelvic plane acquisition using three Methods: percutaneously, with ultrasound and by direct bony acquisition defined as the reference. The mean error for each anterior pelvic plane acquisition method was compared using a univariate variance model for repeated measurements.

In vivo, the mean difference between the perioperative and postoperative abduction angles was 4° and not statistically significant. For anteversion, the difference was 4° and not significant in patients with BMI < 27. The difference was 11° and significant in patients with BMI > 27 (p< 0.001). In vitro, the mean errors for rotation and tilt were respectively 3.8 ° and 19.25 ° for cutaneous acquisition, 2.8° and 6.2° for ultrasound acquisition method. The errors were statistically higher with the percutaneous method (p< 0.001).

According to our results, the accuracy of the standard percutaneous acquisition method of the anterior pelvic plane in computer-assisted THA is limited. The ultrasound acquisition method may represent a reliable alternative.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 93 - 93
1 May 2011
Parratte S Argenson J Since M Pierre PB Pauly V Aubaniac J
Full Access

Introduction: Women have gender specific shape of the distal femur. To fit these gender characteristics, gender specific femoral implants were developed for total knee arthroplasty (TKA). We aimed to compare

objective and subjective functional improvement;

patient satisfaction and preference and

cost-utility ratio after gender specific TKA or standard component implanted on the same women.

Materials and Methods: 30 women (60 knees) operated on successively (6 months in between) for a bilateral TKA between March 2006 and March 2008 by the same surgeon were included in this prospective study. The same surgical protocol and the same post-operative management protocol were applied for both sides. Mean age was 67±3 and mean BMI 26±4 Kg/m2. At a minimum follow-up of one year, evaluation objective and subjective functional improvement, patient satisfaction and preference and cost-utility analysis were performed double blind.

Results: Knee Society knee score and Knee Osteoarthritis Outcome Score (KOOS) improvements were comparable in both groups. However, 75% of the women preferred their gender TKA (p< 0.001). 68% of the women described less crepitus or anterior knee bothering after gender TKA (p=0.003) and 64% had faster recovery with the gender implant (p< 0.001). The cost-utility analysis was favorable for the gender knee.

Discussion: No objective or subjective superiority in terms of functional improvement was shown with gender specific implants at this short-term follow-up. However significant differences in terms of patient satisfaction and preference and a favorable cost-utility analysis were observed. These results should now be confirmed at longer-follow-up. Despite comparative functional improvement, patient satisfaction and preference were higher for the side implanted with a gender specific TKA in this prospective comparative study.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 351 - 356
1 Mar 2009
Parratte S Argenson JA Pearce O Pauly V Auquier P Aubaniac J

We retrospectively reviewed 35 cemented unicompartmental knee replacements performed for medial unicompartmental osteoarthritis of the knee in 31 patients ≤50 years old (mean 46, 31 to 49). Patients were assessed clinically and radiologically using the Knee Society scores at a mean follow-up of 9.7 years (5 to 16) and survival at 12 years was calculated. The mean Knee Society Function Score improved from 54 points (25 to 64) pre-operatively to 89 (80 to 100) post-operatively (p < 0.0001). Six knees required revision, four for polyethylene wear treated with an isolated exchange of the tibial insert, one for aseptic loosening and one for progression of osteoarthritis.

The 12-year survival according to Kaplan-Meier was 80.6% with revision for any reason as the endpoint. Despite encouraging clinical results, polyethylene wear remains a major concern affecting the survival of unicompartmental knee replacement in patients younger than 50.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 258 - 263
1 Feb 2008
Parratte S Kilian P Pauly V Champsaur P Argenson JA

We have evaluated in vitro the accuracy of percutaneous and ultrasound registration as measured in terms of errors in rotation and version relative to the bony anterior pelvic plane in computer-assisted total hip replacement, and analysed the intra- and inter-observer reliability of manual or ultrasound registration.

Four clinicians were asked to perform registration of the landmarks of the anterior pelvic plane on two cadavers. Registration was performed under four different conditions of acquisition. Errors in rotation were not significant. Version errors were significant with percutaneous methods (16.2°; p < 0.001 and 19.25° with surgical draping; p < 0.001), but not with the ultrasound acquisition (6.2°, p = 0.13). Intra-observer repeatability was achieved for all the methods. Inter-observer analysis showed acceptable agreement in the sagittal but not in the frontal plane.

Ultrasound acquisition of the anterior pelvic plane was more reliable in vitro than the cutaneous digitisation currently used.