header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 61 - 61
1 Apr 2018
Takakubo Y Ito J Oki H Momma R Kawaji H Sasaki K Ishii M Takagi M
Full Access

Background

The rate of elderly people over 65 year-old increased from 18.5 % in 2004 to 26.0% in 2015 in Japan. Northern part of Japan is a head of the super-aging society, and the rate already reached 30.9% in 2015. Along with aging society, rapid increase of total hip arthroplasties (THA) has been predicted. The aim of this study is to estimate the trend of total hip arthroplasties in our super-aging area in Northern Japan.

Methods

Trend on number and rate of THA in one of the local area of leading super-aging society were surveyed in the last decade using the database of diagnostic procedure and surgical records from 2004 to 2015. The cause of revision THA was analyzed in 2004–2009 versus in 2010–2015. Spearman's rank-correlation coefficient and student's t-tests were performed using the PASW 18 software (SPSS Institute Inc). Values of p < 0.05 were considered statistically significant.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 30 - 30
1 Jan 2016
Asano T Takagi M Narita A Takakubo Y Suzuki A Sasaki K Oki H
Full Access

Background

A navigation system is useful tool to evaluate the intraoperative knee kinematics. Rheumatoid arthritis (RA) patients often need to have TKA operation, however, there are few TKA kinematics studies comparing RA and Osteoarthritis (OA) patients.

Objective

The purpose of this study was to evaluate intraoperative TKA kinematics, and to describe the difference of kinematics between RA and OA patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 95 - 95
1 Jan 2016
Kawaji H Ishii M Tamaki Y Sasaki K Dairaku K Takakubo Y Naganuma Y Oki H Takagi M
Full Access

Introduction

Patients undergoing total hip arthroplasty (THA) stand in the danger, a particularly high risk for venous thromboembolism (VTE). Fondaparinux and edoxaban, which inhibit FXa, indirectly and directly, respectively, have been used for prevention of VTE after THA in Japan. The aim of this study was to compare the efficacy of fondaparinux and edoxaban for VTE after elective THA in Japanese patients.

Materials and methods

We randomly assigned 320 patients underdoing elective cemented THA to receive postoperative 2.5 mg fondaparinux once daily for first postoperative 3 days and 1.5 mg once daily for the subsequent 7 days (FPX group) [1], postoperative 15 mg edoxaban once daily for postoperative 10 days (EDO15mg group), 30 mg edoxaban once daily for postoperative 10 days (EDO30mg group), and 30 mg edoxaban once daily for first postoperative 3 days and 15 mg once daily for the subsequent 7 days (EDOmix group). Deep venous thrombosis (DVT) was diagnosed by ultrasonography at postoperative day 3 and 14. Computed tomography to detect pulmonary thromboembolism was performed to all patients who had proximal DVTs. The χ2 test with Bonferroni correction was used to compare variables of the incidence of DVT between each group. The intention-to-treat analysis was performed for statistical analysis in each group. The EDO30 mg group and EDOmix group were regarded as one group in the assessment at the postoperative day 3, and named as the EDO30mg+mix group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 121 - 121
1 Jan 2016
Kokubo Y Uchida K Sugita D Oki H Negoro K Inukai T Miyazaki T Nakajima H Yoshida A Baba H
Full Access

Total hip arthroplasty (THA) is one of the preferable solutions for regaining ambulatory activity for patients with end-stage osteoarthritis, and the procedure is well developed technically and large numbers of patients benefit from THA worldwide. However, despite the improvements in implant designs and surgical techniques, revision rates remain high, and the number of revisions is expected to increase in the future as a result of the increase in the volume of primary THA and the increase in the proportion of younger, more active patients who are likely to survive longer than their prosthetic implants. In revision THA, associated loss of bone stock in the acetabulum presents one of the major challenges. The aim of the present study was to analyze the clinical and radiographic outcomes and Kaplan-Meier survivorship of patients underwent revision surgeries of the acetabular cup sustaining aseptic loosening. We reviewed consecutive 101 patients (120 hips; 10 men 11 hips; 91 women 109 hips; age at surgery, 66 years, range, 45–85) who underwent acetabular component revision surgery, at a follow-up period of 14.6 years (range, 10–30). For the evaluation of the state of the acebtabulum, acetabular bony defects were classified according to the classification of the AAOS based on the intraoperative findings as follows; type I [segmental deficiencies] in 24 hips, type II [cavity deficiency] in 48 hips, type III [combined deficiency] in 46, and type IV [pelvic discontinuity] in 2. Basically, we used the implant for acetabular revision surgery that cement or cementless cups were for the AAOS type I acetabular defects, cementless cup, or cemented cup with reinforcement device were for type II, cemented cup with reinforcement device were for type III. Follow-up examination revealed that Harris Hip score improved from 42.5±7.8 points before surgery to 76±16.2 points (p<0.05). The survival rates of the acetabular revision surgery with cemented cups, cementless cups, and cemented cups with reinforcement devices were 65.1%, 72.8%, and 79.8%, respectively, however, there was no significant differences between the groups. There were nine cases, which failed in the early stage in the groups of cementless cups and cemented cups with reinforcement devices, because of the instability of the cementless cups or breakage of reinforcement plates caused by inadequate bone grafting. We conclude that the usage of the cementless cups for type I and II acetabular bony defects, and the cemented cups with reinforcement devices for type III bony defects will demonstrate durable long-term fixation in case of adequate contact between acetabular components and host-bone with restoration of bone stock by impaction bone grafting.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 73 - 73
1 Jan 2016
Naganuma Y Takakubo Y Hirayama T Tamaki Y Oki H Yang S Sasaki K Kawaji H Ishii M Takagi M
Full Access

Introduction

Macrophages phagocytes implant wear debris and produce various cytokines to evoke inflammation and periprosthetic osteolysis of aseptic loosening. It had been reported that expression of Toll-like receptor (TLR) 2 and other TLRs increased in periprosthetic tissues of aseptic loosening. Pathogen-associated molecular patterns (PAMPs) and damaged-associated molecular patterns (DAMPs) have been known as ligands of TLRs and considered to be involved in the osteolytic reactions via TLRs. Another type of immune sensors, nucleotide-binding and oligomerization domain (NOD)-like receptors (NLR) with a pyrin domain 3 (NLRP3) can also recognize PAMPs and DAMPs as their lignds, which has been presumed to participate in the local host response of macrophage cascade via phagocytosis of implant wear particles. However, the contribution of NLRP3 in periprosthetic tissues of aseptic loosening and the correlation between TLR2 and NLRP3 are still unclear.

Materials and methods

TLR1, TLR2, TLR6, NLRP3, TNF-α and IL-1β of macrophages in aseptic loose periprosthetic tissues were immnohistorically evaluated and compared to osteoarthritic synovium. RAW264.7 cells, macrophagic cell line, were stimulated by titanium particles (Ti) and lipoteichoic acid (LTA)-coated Ti. The celluar reaction associated with TLR2 and NLRP3 and the correlation of them were analyzed at mRNA expression levels with small-interfering RNA of Irak2, one of adaptor molecules in TLR2 cascades.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 45 - 45
1 Jan 2016
Takakubo Y Sasaki K Narita A Oki H Naganuma Y Hirayama T Suzuki A Tamaki Y Togashi E Kawaji H Fukushima S Ishii M Takagi M
Full Access

Objectives

Biologic agents (BIO) drastically changed the rheumatoid arthritis (RA) therapy from starting to use biologics at 2003 in Japan. The rate of orthopaedic surgery, especially total joint arthroplasty (TJA) may reflect trends in disease severity, management and health outcomes.

Methods

We surveyed the number and rate of orthopaedic surgeries and TJA in RA treatment with BIO in the last decade, so called BIO-era.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 432 - 432
1 Apr 2004
Omori H Okumura Y Ando M Oki H Hashimoto N Baba H
Full Access

We followed 66 total hip arthroplasties using a cement-less Omniflex femoral component with different surface morphology in 51 patients for a mean of 98 months (72 to 138). There were 57 women and nine men, and the mean age of the patient at the time of operation was 55.4 years (39 to 70). Preoperative diagnosis was osteoarthritis secondary to congenital hip dislocation and dysplasia in 64 hips, rheumatoid arthritis in two hips. This series was divided into three groups according to the extent of surface treatment in the proximal part of the femoral component. A circumferential Hydroxyapatite or titanium plasma-spray coated Omniflex stem was used in 33 hips (Group A). A patchy titanium-beads coated stem and a smooth surfaced stem of the same design were used in 25 hips (Group B) and eight hips (Group C), respectively.

Clinically, the mean Harris Hip Score was 54 points preoperatively, which improved to 89 points at the latest follow-up. Incidence of thigh pain was the lowest in Group A ( 6%) in comparison with in Group B (28%) and Group C (25%). Radiographically, the aseptic loosening rate of the femoral component was none in Group A, 16% in Group B and 75% in Group C. Incidence of femoral osteolysis was almost the same rate among the three groups; 38% in Group A, 40% in Group B, and 50% in Group C. However only in Group A, no Osteolysis was found distal to the lesser trochanter level. The femoral revision was performed in two hips of Group C. This study elucidated that the extent of surface treatment would be one of the important factors to influence the stem stability and the occurence of femoral osteolysis.