header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 154 - 154
1 Jan 2016
Gejo R Motomura H Matsushita I Sugimori K Nogami M Mine H Kimura T
Full Access

Introduction

Balancing of joint gap is a prerequisite in total knee arthroplasty (TKA). Recently, the tensor has been developed which can measure the joint gap with the patellofemoral joint reduced for more physiological assessment, and the results for osteoarthritis (OA) patients indicated that the flexion gap is larger than the extension gap during posterior-stabilized (PS) TKA. However with respect to the rheumatoid arthritis (RA) patients, the soft tissue balance in TKA is still unknown. Therefore, the purpose of this study was toinvestigate thecharacteristics of thejoint gap during TKAsurgeryforpatients with RA.

Methods

We implanted 90 consecutive knees with a PS TKA using a NexGen LPS-flex (Zimmer, Warsaw, IN). OA was the underlying disease in 60 knees and RA was the disease in30 knees.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 320 - 320
1 Dec 2013
Gejo R Motomura H Nogami M Sugimori K Kimura T
Full Access

Introduction:

One of the important factors for success in TKA is to achieve proper stability of the knee joint. It is currently unknown that how much joint laxity exists in mid-range to deep knee flexion, postoperatively. We hypothesized that retaining the PCL or not during TKA has an influence on the postoperative joint laxity from mid-range to deep knee flexion. The purpose of this study was to investigate the postoperative coronal joint laxity throughout the full range of motion by the 3-dimensional in vivo analysis, both in PS and CR TKA.

Methods:

We implanted 5 knees with a PS TKA using a NexGen LPS-flex and 5 knees with a CR TKA using a NexGen CR-flex. All of them were the osteoarthritis patients. We performed all operations with a measured resection technique. Four weeks after TKA, the valgus- and varus-stress radiographic assessments were performed at the five flexion angles from full extension to maximum flexion. The patients sat on the radiolucent chair with their lower legs hanging down. The examiner held their thigh, and a force of 50N was applied 30 cm distal to the tibiofemoral joint. The series of static fluoroscopic images via a flat panel detector were stored digitally. A 3-dimentional to 2-dimentional techniqueusing an automated shape-matching algorithm was employed to determine the relative 3-dimentional positions of the femoral component and tibial component in each fluoroscopic image (KneeMotion; LEXI, Tokyo). On the coronal plane of the tibial component, the angle between the tangent line of the condyles of the femoral component and the tibial plateau was measured as the joint laxity for valgus (α valgus) or varus (α varus). The flexion angle between the femoral component and tibial component was also measured.