header advert
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims

The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design.

Methods

This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions.


Bone & Joint Open
Vol. 3, Issue 7 | Pages 589 - 595
1 Jul 2022
Joo PY Chen AF Richards J Law TY Taylor K Marchand K Clark G Collopy D Marchand RC Roche M Mont MA Malkani AL

Aims

The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up.

Methods

This was a multicentre registry study from October 2016 to June 2021 that included 861 primary RA-TKA patients who completed at least one pre- and postoperative patient-reported outcome measure (PROM) questionnaire, including Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR), and pain out of 100 points. The mean age was 67 years (35 to 86), 452 were male (53%), mean BMI was 31.5 kg/m2 (19 to 58), and 553 (64%) cemented and 308 (36%) cementless implants.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 59 - 66
1 Jun 2021
Abhari S Hsing TM Malkani MM Smith AF Smith LS Mont MA Malkani AL

Aims

Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment.

Methods

A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 7 - 7
1 Oct 2020
Goswami K Clarkson S Dennis DA Klatt BA O'Malley M Smith EL Pelt CE Gililland J Peters C Malkani AL Palumbo B Minter J Goyal N Cross M Prieto H Lee G Hansen E Ward D Bini S Higuera C Levine B Nam D Della Valle CJ Parvizi J
Full Access

Introduction

Surgical management of PJI remains challenging with patients failing treatment despite the best efforts. An important question is whether these later failures reflect reinfection or the persistence of infection. Proponents of reinfection believe hosts are vulnerable to developing infection and new organisms emerge. The alternative hypothesis is that later failure is a result of an organism that was present in the joint but was not picked up by initial culture or was not a pathogen initially but became so under antibiotic pressure. This multicenter study explores the above dilemma. Utilizing next-generation sequencing (NGS), we hypothesize that failures after two stage exchange arthroplasty can be caused by an organism that was present at the time of initial surgery but not isolated by culture.

Methods

This prospective study involving 15 institutions collected samples from 635 revision total hip (n=310) and knee (n=325) arthroplasties. Synovial fluid, tissue and swabs were obtained intraoperatively for NGS analysis. Patients were classified per 2018 Consensus definition of PJI. Treatment failure was defined as reoperation for infection that yielded positive cultures, during minimum 1-year follow-up. Concordance of the infecting pathogen cultured at failure with NGS analysis at initial revision was determined.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 65 - 65
1 Oct 2020
Abhari S Hsing T Malkani M Smith AF Smith LS Malkani AL
Full Access

Introduction

Mechanical axis limb alignment in total knee arthroplasty (TKA) has demonstrated excellent long-term survivorship; however, patient satisfaction continues to demand improvement. Alternative emerging alignment concepts including kinematic and tibial constitutional varus have been introduced but remain controversial. The purpose of this study was to evaluate outcomes and patient satisfaction following TKA with tibial components placed in constitutional varus alignment.

Methods

This was a retrospective cohort analysis from a total joint registry of 114 patients with preoperative varus deformity who underwent primary TKA with tibial component placed in 1–3 degrees of constitutional varus. The group included 59 males (52%) and 55 (48%) females with a mean age of 67 years (range 43 – 85) and mean BMI of 32.0 kg/m2 (range 21 – 51 kg/m2) with a minimum 1 year follow-up. Patients were stratified into 3 groups based on the preoperative varus alignment: Group A between 1°- 5° varus (43 knees), Group B between 6°- 10° (56 knees), and Group C greater than 10° (16 knees). The target constitutional tibial varus alignment was selected based on the extent of the patient's deformity.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 52 - 52
1 Oct 2019
Korte EA Malkani AL Gaskins J Hartley B Langman LJ Jannetto P McMillin G Maluf C Jortani SA
Full Access

Introduction

Insufficient pain control following lower extremity surgery can increase length of stay, readmission rates, and impair postoperative outcome. It has been shown that CYP2D6 genotypes predict function of the enzyme responsible for conversion of hydrocodone to hydromorphone (active metabolite) and plasma concentration of hydromorphone best predicted analgesic response. Purpose of this study was to evaluate relationship of CYP2D6 genotypes, drug-drug interactions, and plasma drug concentrations in patients undergoing lower extremity surgery.

Methods

A prospective cohort of 271 orthopedic patients undergoing lower extremity surgery including TKA, THA and trauma were queried. Patients treated with hydrocodone were enrolled and tested for plasma concentrations of hydrocodone and hydromorphone. CYP2D6 genotyping was performed. Medications co-administered with hydrocodone during perioperative and postoperative periods were queried.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 10 - 16
1 Jul 2019
Fillingham YA Darrith B Calkins TE Abdel MP Malkani AL Schwarzkopf R Padgett DE Culvern C Sershon RA Bini S Della Valle CJ

Aims

Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA. The purpose of this multicentre randomized clinical trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA.

Patients and Methods

From six-centres, 233 revision TKAs were randomized to one of four regimens: 1 g of intravenous (IV) TXA given prior to the skin incision, a double-dose regimen of 1 g IV TXA given both prior to skin incision and at time of wound closure, a combination of 1 g IV TXA given prior to skin incision and 1 g of intraoperative topical TXA, or three doses of 1950 mg oral TXA given two hours preoperatively, six hours postoperatively, and on the morning of postoperative day one. Randomization was performed based on the type of revision procedure to ensure equivalent distribution among groups. Power analysis determined that 40 patients per group were necessary to identify a 1 g/dl difference in the reduction of haemoglobin postoperatively between groups with an alpha of 0.05 and power of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 3 - 9
1 Jul 2019
Shohat N Tarabichi M Tan TL Goswami K Kheir M Malkani AL Shah RP Schwarzkopf R Parvizi J

Aims

The best marker for assessing glycaemic control prior to total knee arthroplasty (TKA) remains unknown. The purpose of this study was to assess the utility of fructosamine compared with glycated haemoglobin (HbA1c) in predicting early complications following TKA, and to determine the threshold above which the risk of complications increased markedly.

Patients and Methods

This prospective multi-institutional study evaluated primary TKA patients from four academic institutions. Patients (both diabetics and non-diabetics) were assessed using fructosamine and HbA1c levels within 30 days of surgery. Complications were assessed for 12 weeks from surgery and included prosthetic joint infection (PJI), wound complication, re-admission, re-operation, and death. The Youden’s index was used to determine the cut-off for fructosamine and HbA1c associated with complications. Two additional cut-offs for HbA1c were examined: 7% and 7.5% and compared with fructosamine as a predictor for complications.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2018
Fillingham YA Darrith B Calkins T Abdel MP Malkani AL Schwarzkopf R Padgett DE Sershon RA Bini S Della Valle CJ
Full Access

Introduction

Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA that is associated with greater blood loss. The purpose of this multi-center randomized trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA.

Methods

233 Septic and aseptic revision TKA from six-centers were randomized to either receive 1g pre-incision intravenous (IV) TXA, 1g pre- and post-incision IV TXA, 1g pre-incision IV and 1g intra-operative topical TXA, or three doses of 1950mg oral TXA given 2 hours pre-operatively, 6 hours post-operatively, and the morning of postoperative day 1. Randomization was performed based on type of revision to ensure equivalent distribution among groups. The primary outcome was reduction in hemoglobin. Power analysis determined 40 patients per group were necessary to identify a 1g/dL difference with an alpha of 0.05 and beta of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence.