header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 14 - 14
1 Feb 2016
Lang Z Tian W Liu Y Liu B Yuan Q
Full Access

Minimally invasive (MIS) screw fixation for Hangman's fracture can decrease iatrogenic soft-tissue injury compared with conventional open approach, but increase the risk of instrumentation-related complications due to lack of anatomical landmarks. With the advantages, the intra-operative three-dimensional fluoroscopy-based navigation (ITFN) system seems to be an inherent partner for MIS techniques. The purpose of this study was to evaluate the accuracy and feasibility of MIS techniques incorporating with ITFN for treating Hangman's fracture. 20 patients with Hangman's fracture underwent C2-C3 pedicle screw fixation using ITFN. 6 patients used MIS technique, with the other 14 patients using conventional open technique. Preoperative visual analogue score (VAS) was 5.7±1.4 in CAOS-MIS group and 5.5±0.9 in CAOS-open group. Operative time, blood loss and postoperative neurovascular complications were recorded. The accuracy of screw positions was studied by postoperative CT scan. All patients were followed up for at least 6 months and the fusion status was ascertained by dynamic radiographs. The average operative time was 134.2±8.0 min in CAOS-MIS group and 139.3±25.8 min in CAOS-open group, and there was no significant difference between the two (p>0.01). The blood loss was 66.7±25.8 ml in CAOS-MIS group and 250.0±141.4 ml in CAOS-open group. Statistical difference existed with CAOS-MIS group significant less than CAOS-open group (p<0.01). A total of 80 screws were inserted. No screw-related neurovascular injury was observed. Post-operative CT scan revealed 83.3% (20/24) screws of grade 1 and 16.7% screws of grade 2 (4/24) in CAOS-MIS group, meanwhile 89.3% screws of grade 1 (50/56) and 10.7% screws of grade 2 (6/56) in CAOS-open group. There was no grade 3 screw detected. Fisher's exact test showed there was no statistical difference between these two groups (p>0.01). There was no statistical difference in pre-operative VAS between these two groups (p>0.01). Compared with the CAOS-open group (1.7±0.6), neck pain VAS at 6-month follow-up in CAOS-MIS group (0.3±0.5) was significantly lower (p<0.01). Solid fusion was demonstrated in all the cases by dynamic radiographs. So it is feasible and safe for percutaneous minimally invasive C2-C3 pedicle screw fixation for Hangman's fracture using intra-operative three-dimensional fluoroscopy-based navigation, which can also decrease the incidence of post-operative neck pain.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 152 - 152
1 Jan 2016
Liu B Lodge C Budgen A
Full Access

Background

Operative fixation of acute tendo-achilles ruptures remains controversial. Standard surgical exposure is associated with and increased risk of wound breakdown and infections. The mini-open technique was developed to minimise these risks and provide anatomical reduction/apposition of the tendon rupture.

Methods

We present a retrospective case series of 27 patients who were treated operatively for acute Achilles tendon rupture in the hands of 1 surgeon, between 4–6 years post operatively, using Achillon instrumentation. Post operatively they were treated with an air cast boot and 3 wedges, bringing the foot into neutral by 6 weeks followed by a rehabilitation programme. The patients were contacted via telephone and consent was obtained. The complications, Leppilahti score and ATRS score were then calculated.