Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 8 - 8
1 May 2016
Grimm B Lipperts M Senden R
Full Access

Introduction

The goal of total hip arthroplasty (THA) is to reduce pain, restore function but also activity levels for general health benefits or social participation. Thus evaluating THA patient activity can be important for diagnosis, indication, outcome assessment or biofeedback.

Methods

Physical activity (PA) of n=100 primary THA patients (age at surgery 63 ±8yrs; 49M/51F; 170 ±8cm, 79.8 ±14.0kg) was measured at 8 ±3yrs follow-up. A small 3D accelerometer was worn for 4 successive days during waking hours at the non-affected lateral upper leg. Data was analyzed using validated algorithms (Matlab) producing quantitative (e.g. #steps, #transfers, #walking bouts) and qualitative (e.g. cadence, temporal distribution of events) activity parameters. An age matched healthy control group (n=40, 69 ±8yrs, 22M/18F) served as reference.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 9 - 9
1 May 2016
Grimm B Moonen M Lipperts M Heyligers I
Full Access

Introduction

Unicompartmental knee arthroplasty is in particular promoted for knee OA patients with high demands on function and activity. This study used wearable inertial sensors to objectively assess function during specific motion tasks and to monitor activities of daily living to verify if UKA permits better function or more activity in particular with demanding tasks.

Methods

In this retrospective, cross-sectional study, UKA patients (Oxford, n=26, 13m/13f, age at FU: 66.5 ±7.6yrs) were compared to TKA patients (Vanguard, n=26, 13m/13f, age: 66.0 ±6.9yrs) matched for gender, age and BMI (29.5 ±4.6) at 5 years follow-up.

Subjective evaluation of pain, function, physical activity and awareness of the joint arthroplasty was performed by means of four PROMs: VAS pain, KOOS-PS, SQUASH (activity) and Forgotten Joint Score (FJS),

Objective measurement of function was performed using a 3D inertia sensor attached to the sacrum while performing gait test, sit-stand and block-step tests. To derive functional parameters such as walking cadence or sway during transfers or step-up previously validated algorithms were used (Bolink et al., 2012).

Daily physical activity was objectively monitored with a 3D accelerometer attached to the lateral side of the unaffected upper leg during four consecutive days. Activity parameters (counts and times of postures, steps, stairs, transfers, etc.) were also derived using validated algorithms. Data was analysed using independent T-test, Mann-Whitney U test and Pearson's correlation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 26 - 26
1 Feb 2013
Brunton L Bolink S van Laarhoven S Lipperts M Grimm B Heyligers I Blom A
Full Access

Accelerometer based gait analysis (AGA) is a potential alternative to the more commonly used skin marker based optical motion analysis system(OMAS). The use of gyroscopes in conjunction with accelerometers (i.e. inertial sensors), enables the assessment of position and angular movements of body segments and provides ambulatory kinematic characterisation of gait.

We investigated commonly used gait parameters and also a novel parameter, Pelvic obliquity (PO) and whether they can be used as a parameter of physical function and correlate with classic clinical outcome scores

Gait was studied in healthy subjects (n=20), in patients with end stage hip OA (n=20) and in patients with end stage knee OA (n=20). Subjects walked 20 metres in an indoor environment along a straight flat corridor at their own preferred speed. A 3D inertial sensor was positioned centrally between the posterior superior iliac spines (PSIS) overlying S1.

Comparing gait parameters of end stage hip OA patients with an age and gender matched healthy control group, significantly lower walking speed, longer step duration and shorter step length was observed. After correcting for walking speed between groups, significantly less average range of motion of PO (RoMpo) was observed for patients with end stage hip OA compared to healthy subjects and patients with end stage knee OA.