header advert
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 168 - 168
1 Sep 2012
Bolland B Howell J Hubble M Timperley A Gie G Ling R
Full Access

Background

Since 1991 to 2008 approximately 800,000 Exeter stems have been sold worldwide with 80 reported cases of fracture (neck or stem). This study aimed to determine factors predisposing to fracture.

Method

Clinical, surgical, radiological and retrieval data was collated from Stryker Benoist-Girard and Exeter research databases. Risk factors associated with fracture were categorised to patient related (weight and activity levels), surgical related (poor medial support, component size, placement) and implant related (+ head).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 143 - 143
1 Feb 2012
Lewthwaite S Squires B Gie G Timperley J Howell J Hubble M Ling R
Full Access

Aim

The aim of this study was to determine the medium term survivorship and function of the Exeter Universal Hip Replacement when used in younger patients, a group that is deemed to place high demands on their arthroplasties. Since 1988 The Exeter Hip Research Unit has prospectively gathered data on all patients who have had total hip replacements at the Princess Elizabeth Orthopaedic Hospital. There were 130 Exeter Universal total hip replacements (THR) in 107 patients who were 50 years or younger at the time of surgery and whose surgery was performed at least 10 years before. Mean age at surgery was 42 years (range 17-50 years.) Six patients who had 7 THRs had died, leaving 123 THRs for review. Patients were reviewed at an average of 12.5 years (range 10-17 years). No patient was lost to follow-up.

Results

At review, 12 hips had been revised. Of these, 9 were for aseptic loosening of the acetabular component and one cup was revised for focal lysis and pain. One hip was revised for recurrent dislocation. One femoral component required revision in 1 case of infection. Radiographs showed that a further 11 (10%) of the remaining acetabular prostheses were loose but that no femoral components were loose. Survivorship of stem and cup from all causes was 94%, at an average of 12.5 years. Survivorship of stem only from all causes was 99% and from aseptic loosening was 100%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 59 - 59
1 Feb 2012
Carrington N Sierra R Hubble M Gie G Ling R Howell J
Full Access

Purpose

We describe an update of our experience with the implantation of the first 325 Exeter Universal hips. The fate of every implant is known.

Methods and results

The first 325 Exeter Universal stems (309 patients) were inserted between March 1988 and February 1990. The procedures were undertaken by surgeons of widely differing experience. Clinical and radiological review was performed at a mean of 15.7 years. At last review 185 patients had died (191 hips). 103 hips remain in situ. Survivorship at 17 years with revision for femoral component aseptic loosening was 100% (95% CI 97 to 100), with revision for acetabular component aseptic loosening was 90.4% (95% CI 83.1 to 94.7) and with any re-operation as the endpoint was 81.1% (95% CI 72.5 to 89.7). 12 patients (12 hips) were not able to attend for review due to infirmity or emigration, and scores were obtained by phone (x-rays were obtained in 4 patients). Mean D'Aubigné and Postel scores (Charnley modification) at review were 5.4 for pain and 4.8 for function. The mean Oxford score was 21.6 +/− 9.8 and the mean Harris score 71.7 +/− 19.7. On radiological review there were no femoral component failures. Three sockets (2.9%) were loose as demonstrated by migration or change in orientation (two patients were asymptomatic) and 5 sockets (4.9%) had radiolucent lines in all 3 zones but no migration. There are two patients awaiting socket revision.