header advert
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 33 - 33
1 Dec 2017
Letissier H Walch G Boileau P Le Nen D Stindel E Chaoui J
Full Access

Introduction

Reverse Total Shoulder Arthroplasty (rTSA) is an efficient treatment, to relieve from pain and to increase function. However, scapular notching remains a serious issue and post-operative range of motion (ROM) presents many variations. No study compared implant positioning, different implant combinations, different implant sizes on different types of patient representative to undergo for rTSA, on glenohumeral ROM in every degree of freedom.

Material and Methods

From a CT-scan database classified by a senior surgeon, CT-exams were analysed by a custom software Glenosys® (Imascap®, Brest, France). Different glenoid implants types and positioning were combined to different humerus implant types. Range of motion was automatically computed. Patients with an impingement in initialisation position were excluded from the statistical analysis. To validate those measures, a validation bench was printed in 3D to analyse different configurations.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 43 - 43
1 Mar 2017
Murphy S Murphy W Elsharkawy K Le D
Full Access

Introduction

While total hip arthroplasty is considered to be one of the most cost-effective medical interventions, the total cost of care for a population patients treated by THR can present a significant burden on the payer, whether it be an employer, private insurer or government. Data on the true cost of care has rarely been made available to the treating physician. Such lack of information makes comprehensive management difficult. Bundled payment models of care require knowledge of all costs associated with the care of our patients and opens new opportunity for analysis to improve management and outcomes. The current study assess the influence of surgical technique on total cost of care for total hip arthroplasty.

Methods

Payment data for 341 patients who underwent total hip arthroplasty at a single institution from June 1st, 2011 to October 31st, 2014 were analyzed. Each procedure was performed using either the superior, anterior, or posterior exposure. The superior exposure was performed with femoral head excision and without dislocation of the hip. The data were analyzed for total cost, inpatient cost, inpatient physician cost, readmission cost, skilled nursing facility cost, and home healthcare agency cost among the different approaches.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 24 - 24
1 Mar 2017
Mitchell R Smith K Murphy S Le D
Full Access

BACKGROUND

Ideal treatment of displaced femoral neck fragility fractures in the previously ambulatory patient remains controversial. Treating these patients with total hip arthroplasty has improved patient reported outcomes and reduced rates of revision surgery compared to those treated with hemiarthroplasty. However, possible increased risk of dislocation remains a concern with total hip arthroplasty.

The anterolateral and direct anterior approaches to total hip replacement have been applied in the femoral neck fracture population to minimize dislocation rates. However, the anterolateral approach has been associated with abductor injury and increased rates of heterotopic ossification while the anterior approach has been associated with peri-prosthetic femur fracture, lateral femoral cutaneous nerve injury, and wound complications. The Supercapsular Percutaneously Assisted (SuperPATH) approach was developed to minimize disruption of the capsule and short-external rotators in an effort to reduce the risk of dislocation and assist in quicker recovery in the elective hip arthroplasty setting. To achieve this, the SuperPATH technique allows the femur to be prepared in situ and the acetabulum to be reamed percutaneously once the femoral head is removed.

This study investigates the post-operative time to ambulation, length of stay, discharge destination, and early dislocation rate of previously ambulatory patients with a displaced femoral neck fragility fracture that were treated with a total hip arthroplasty via the SuperPATH technique.

METHODS

A retrospective chart review was performed of previously ambulatory patients consecutively treated for a displaced femoral neck fragility fracture with a total hip replacement using the SuperPATH technique. Thirty-five patients were included in the study and examined for demographic data, time to ambulation, length of stay, major and minor complications during their hospital stay. Phone interviews were conducted to check for dislocation events.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 11 - 11
1 Mar 2017
Smith K Mitchell R Le D
Full Access

BACKGROUND

The need for post-operative manipulation under anesthesia (MUA) for stiffness after primary total knee arthroplasty is a frustrating complication that can lead to suboptimal outcomes if range-of-motion to a functional level is not regained. Implant morphology and kinematics, PCL imbalance, and soft-tissue balancing can all contribute to post-operative stiffness. Utilization of total knee arthroplasty components that replicate the native knee's medial ball and socket kinematics may lead to easier maintenance of flexion post-operatively compared to conventional components.

PURPOSE

To determine if a medial pivot total knee arthroplasty design can reduce the need for post-operative MUA after primary total knee arthroplasty.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 44 - 44
1 Mar 2017
Murphy S Murphy W Le D
Full Access

INTRODUCTION

Patients less than 60 years old have been reported to have a higher risk of revision following total hip arthroplasty (THA) than older patient cohorts, possibly to due higher activity, a higher incidence of deformity and greater probability of prior surgery. Ceramic-on-ceramic bearing surfaces have been proposed for use in young and active individuals due to their low wear, low risk of adverse biologic reaction, and long-term survivorship. We assessed the clinical results and long-term survivorship of uncemented ceramic-on-ceramic THA in a young patient population.

METHODS

For the six year period from May 1999 to March 2005, 278 hip replacements in 244 patients less than 60 yeas of age at the time of surgery were performed using alumina ceramic-ceramic bearings. All hips had uncemented titanium femoral and acetabular components. The ceramic liner was fixed to the shell with an 18-degree flush-mounted taper design. Patients were followed clinically and radiographically. Attempts were made to contact all patients who had not been seen in the prior 3 years. Of the 278 hips, 17 hips (16 patients) remain lost to follow-up, leaving 261 hips (228 patients; 155 hips in men, 106 hips in women) for assessment. Mean age of the patients was 46.2 years at the time of surgery (range 17.8 to 59.9 years). 17% of hips had at least one previous hip surgery. Mean time following surgery was 9.75 years (range 2 to 16.8 years).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 107 - 107
1 Feb 2017
Le D Mitchell R Smith K
Full Access

INTRODUCTION

The direct anterior approach to THR has become an increasingly popular minimally-invasive technique in an effort to minimize dislocation risk, facility early recovery, and diminish soft tissue injury. However, it has been associated with unique complications including intraoperative femur fracture, cutaneous nerve palsy, stem subsidence, and wound healing complications. These risk of these complications have been documented to be more likely in the surgeon's early experience with the approach. The minimally-invasive Supercapsular Percutaneous-Assisted (SuperPATH) technique was developed to minimize capsular and short-external rotator injury, minimize dislocation risk, and provide an easier transition from the standard posterior approach.

METHODS

Fifty (50) consecutive elective total hip replacements in 48 patients were performed using the SuperPATH technique. These also represented the first fifty elective THRs the surgeon performed in practice. Indications were primary or secondary osteoarthritis (92%), avascular necrosis (6%), and impending pathologic fracture (2%). Patients were evaluated retrospectively for dislocation, major, and minor complications.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 106 - 106
1 Feb 2017
Le D Smith K Mitchell R
Full Access

Introduction

Orientation of the acetabular component in total hip arthroplasty has been shown to influence component wear, stability, and impingement. Freehand placement of the component can lead to widely variable radiographic outcomes. Accurate abduction, in particular, can be difficult in the lateral decubitus position due to limited ability to appreciate and control positional obliquity of the pelvis. A CT-based mechanical navigation device has been shown to decrease cup placement error. This is an independent report of a single-surgeon's radiographic results using the device to control cup abduction.

Patients and Methods

Sixty-four (64) consecutive elective THRs in 58 patients were performed via a supercapsular percutaneously-assisted (SuperPATH) surgical approach. Intraoperatively, the acetabular components were aligned with the aid of the CT-based mechanical navigation device (HipXpert; Surgical Planning Associates, Medford, MA). The cup orientation was then further adjusted to ensure that the anterior rim of the acetabular component was not prominent to avoid psoas impingement. Postoperatively, radiographic abduction was measured on standing postoperative radiographs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 71 - 71
1 May 2016
Elsharkawy K Murphy W Le D Eberle R Talmo C Murphy S
Full Access

INTRODUCTION

Evolving payment models create new opportunities for assessment of patient care based on total cost over a defined period of time. These models allow for analyses of economic data that was previously unavailable and well beyond our familiar studies which typically include length of stay, surgical complications, and post-operative clinical and radiographic assessments. In the United States, the new Federal program entitled TheBundled Payment for Care Initiative created new opportunities for the assessment of surgical interventions. The purpose of the reported study was to assess the total reimbursement for care as a function of surgical technique in primary total hip arthroplasty (THA).

METHODS

The total reimbursement for services performed following primary THA for patients insured by Medicare was analyzed for a group of patients at a single institution during the fiscal years of 2013 and 2014. The population included data on 356 patients who had surgery performed by seven surgeons who used the same pre-operative education, OR, PACU, PT, nursing, and case management. A total of 38 “pre-selected” patients underwent THA by an anterior exposure, 219 had surgery performed by a posterior exposure, and 99 had surgery performed by the superior exposure utilizing mechanical surgical navigation (HipXpert System, Surgical Planning Associates, Boston, MA). Reimbursement for all in-patient and out-patient services performed over the initial 90-day period from sugeical admission was compared across surgical techniques. Reimbursement includes the sum of all payments including the hospital, physicians, skilled nursing facilities, home care, out-patient care, and readmission.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 69 - 69
1 Jan 2016
Murphy S Le D Murphy W
Full Access

INTRODUCTION

Young patients (< 50 years old) have been reported to have a higher risk of revision following total hip arthroplasty (THA) than older patient cohorts, possibly to due higher activity, a higher incidence of deformity and greater probability of prior surgery. Ceramic-on-ceramic bearing surfaces have been proposed for use in young and active individuals due to their low wear, low risk of adverse biologic reaction, and long-term survivorship. We assessed the clinical results and long-term survivorship of uncemented ceramic-on-ceramic THA in a young patient population.

METHODS

Between August 1999 and December 2007, 220 total hip arthroplasties in 191 patients under 50 years of age at the time of surgery were performed using alumina ceramic-ceramic bearings as part of a prospective, non-randomized study. All patients received uncemented acetabular components with flush-mounted acetabular liners using an 18 degree taper, and uncemented femoral components. The average patient age at the time of surgery was 42.1 ±7.2 years (range: 17.4 years to 49.9 years), and the average time to follow-up was 10.1 ±2.4 years (range: 4.2 years to 15.2 years). We evaluated implant-related complications and performed Kaplan-Meier analyses to determine survivorship of the THA components with revision for any reason as the endpoint.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 66 - 66
1 Jan 2016
Murphy S Murphy W Le D Kowal JH
Full Access

Introduction

Cup malposition in hip arthroplasty and hip resurfacing is associated with instability, accelerated wear, and the need for revision. A recent study measuring cup orientation on conventional radiodiographs demonstrated an incidence of cup malpositioning of 50% according to the safe zone that they defined 1,2. A prior study of 105 conventionally placed cups using CT demonstrated a cup malpositioning incidence of 74%3. The current study similarly assesses the variation in cup position using conventional techniques as measured by CT.

Methods

CT studies of 123 hips in 119 patients with total hip arthroplasties performed using conventional techniques were used for this study. The indications for the CT studies were for CT-based surgical navigation of the contralateral side or for assessment of periprosthetic osteolysis. An application specific software modules was developed to measure cup orientation using CT (HipSextant Research Application 1.0.13 Surgical Planning Associates Inc., Boston, Massachusetts). The cup orientation was determined by first identifying Anterior Pelvic Plane Coordinate system landmarks on a 3D surface model. A multiplanar reconstruction module then allowed for the creation of a plane parallel with the opening plane of the acetabulum. The orientation of the cup opening plane in the AP Plane coordinate space was calculated according to Murray's definitions of operative anteversion and operative inclination. Since these studies including images through the femoral condyles, femoral anteversion could be measured on these hips as well (Osirix v5.6, Pixmeo SARL, Bernex, Switzerland).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 393 - 393
1 Dec 2013
Murphy S Le D
Full Access

Introduction

Adverse Local Tissue Reactions (ALTR) have been reported in association with both wear and corrosion. Tissue reactions have been reported in association with corrosion at CoCr head-CoCr neck, CoCr head-TiAl6V4 neck, and CoCr modular neck on beta-titanium (TMZF) stem junctions. The current abstract reports on 3 cases of ALTR in association with CoCr modular necks on convention titanium (TiAl6V4) stem junctions.

Case 1. A 67 year old male (87 kg, 1.73 m, BMI 29.1) presented with new onset hip irritation 11 months after surgery. Radiographs show no abnormalities. Further investigation revealed the following: ESR = 95, CRP = 5, Cr level = 1.0, Co level = 4.1, leukocyte transformation testing = highly reactive to nickel. Hip aspiration was culture negative with 11,250 wbc. Metal artifact reduction MR showed cystic local reaction in the region of the greater trochanter.

Case 2. A 52 year old male (89 kg, 1.83 m, BMI 26.5) presented with new onset hip irritation 30 months after surgery. Radiographs show no abnormalities. Further investigation revealed the following: ESR = 7, CRP = 5.4, Cr level = 2.1, Co level = 4.8, leukocyte transformation testing = reactive to nickel. Hip aspiration was culture negative with 3995 wbc. Metal artifact reduction MR showed cystic local reaction in the region of the iliopsoas.

Case 3. A 52 year old male (104 kg, 1.85 m, BMI 30.1) presented with new onset hip irritation 26 months after surgery. Radiographs show no abnormalities. Further investigation revealed the following: ESR = 33, CRP = 34.9, Cr level = 1.0, Co level = 3.7, leukocyte transformation testing = no reactivity to any of the biomaterials. Hip aspiration was culture negative with 3,780 wbc. Metal artifact reduction MR showed cystic local reaction in the region of the iliopsoas.

Discussion

All three of these patients are scheduled for revision surgery. All three had ceramic-ceramic bearings. We have experience with 1029 ceramic-ceramic THA with fixed neck conventional titanium and modular titanium neck implants with minimum 2 yr f/u and have never diagnosed an adverse reaction in any of these patients. It is possible that corrosion at the CoCr neck on TiAl6V4 stem junction is the root cause of these reactions. Although the incidence of diagnosed reactions is roughly 1%, it appears that the use of CoCr at any junction under significant mechanical stress can result in adverse local tissue reaction and therefore should either be avoided or used with great caution and compelling indications.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 394 - 394
1 Dec 2013
Murphy S Murphy W Le D
Full Access

Introduction:

Young patients have been reported to have a higher risk of revision following total hip arthroplasty (THA) than older cohorts, possibly to due higher activity and a higher incidence of deformity and prior surgery. Ceramic-on-ceramic bearing surfaces have been proposed for use in young and active individuals due to their low wear, low risk of adverse biologic reaction, and long-term survivorship. We assessed the clinical results and long-term survivorship of uncemented ceramic-on-ceramic THA in a young patient population.

Methods:

341 total hip arthroplasties in 218 patients under 50 years of age at the time of surgery were performed were performed using alumina ceramic-on-ceramic bearings from August 1999 to April 2009 as part of a prospective nonrandomized study. All patients received uncemented acetabular components with flush-mounted acetabular liners using an 18 degree taper and uncemented femoral components. The average patient age at the time of surgery was 41.7 years (range 17.8–49.9 years). The minimum follow-up time was 2 years, (mean 9.1, range 2–13.9). We evaluated implant-related complications and performed Kaplan-Meier analyses to determine survivorship of the femoral and acetabular components with revision for any reason as the endpoint.