Introduction

We describe a novel single incision approach and its safety in the largest reported series of Lisfranc injuries to date. Via separate subcutaneous windows it is possible to access the medial three rays of the foot for bridge plating, without the concern of narrow skin bridges between multiple incisions.

Methods

A retrospective review identified all 150 patients who underwent a Lisfranc ORIF via the modified dorsal approach at the Royal Melbourne Hospital between January 2011 and June 2016. All patients were operated by a single surgeon. Removal of metalwork (ROM) was routinely undertaken at six months post-operatively via the same incision. Medical recored were reviewed to record patient demographics, mechanism of injury and surgical details. Outpatient notes were reviewed to identify wound-related complications including; delayed wound healing, superficial infection, wound dehiscence, deep infection, complex regional pain syndrome (CRPS), neuroma and impaired sensation. Median follow-up was 1012 days (range 188–2141).