Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 49 - 49
1 Dec 2019
Giordano G Krin G Portet Y Bouige A Fourcade C Bonnet E
Full Access

Aims

To evaluate the place of the massive prostheses in the most complex periprosthetic infections cases (PJis).

Method

Between 2011 and 2017, 516 hip and knee revisions for periprosthetic infections had been performed in our hospital by the same senior surgeon. We report a prospective series of 58 patients treated between 2011 and the end of 2017. 26 males and 32 females with on average 69,4 years old (38–86). Infection involved TKA in 39 cases (26 TKA revisions, 11 primary TKA), THA in 18 cases (10 revisions, 7 primary THA), a femoral pseudoarthrosis with posttraumatic gonarthrosis in one case and a septic humeral pseudoarthrosis in one case.

We used one stage procedures in 38 cases (14 hips, 23 knees, 1 shoulder) and 20 two stages surgeries (16 knees and 4 hips). Additional technics used with massive prostheses, all for TKA PJis: 4 massive extensor systemallografts performed two times in a one stage procedure, two local flaps (medial gastronecmienmuscle). Two perioperative hyperbaric procedures used to limit the risks of wound complications.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 32 - 32
1 Dec 2017
Bicart-Sée A Bouige A Fourcade C Krin G Arnaud S Conte P Félicé M Bonnet E Giordano G Rottman M
Full Access

Aim

Pre-operative distinction between prosthetic joint infections (PJI) and non-infectious causes of joint failure is particularly challenging, especially in chronic situations. Guidelines propose different algorithms using numerous preoperative tests. We evaluated place of serology.

Method

During a 9 month period, we included consecutive patients undergoing arthroplasty revision for a suspected chronic hip or knee infection. Serologies were sampled at the same day than the other blood tests. Results were compared with the final diagnosis, determined with peroperative bacteriological and histological results.

Serology was performed using a multiplex antibody detection*. This multiplex antibody detection assay detects antibodies against Staphylococcus species, Propionibacterium acnes and Streptococcus agalactiae.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 6 - 6
1 Dec 2017
Bouige A Fourcade C Bicart-Sée A Félicé M Gautié L Krin G Marlin P Giordano G Bonnet E
Full Access

Aim

Ceftobiprole, a broad-spectrum cephalosporin, could be used for post-operative treatment of bone implant-associated infections. The aim of the study is to evaluate the in vitro susceptibility of bacteria isolated from bone implant-associated infections to ceftobiprole.

Method

We conducted an in vitro, retrospective and comparative study between July 2013 to April 2017 including patients with bone implant-associated infections (prosthesis joint infection (PJI) and osteosynthesis material (OM)). To evaluate MIC distribution of ceftobiprole against Gram positive and Gram negative strains and to compare activity of ceftobiprole to vancomycin for Gram positive and ceftriaxone or ceftazidime for Gram negative strains, we tested all strains (stored in Cryobank storage system) for minimal inhibitory concentrations (MIC) determination by E-test bandelet for ceftobiprole and comparator antibiotics.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 82 - 82
1 Dec 2017
Bouige A Fourcade C Bicart-Sée A Félicé M Gautié L Krin G Hascoet JL Marlin P Giordano G Bonnet E
Full Access

Aim

Prosthetic joint infections (PJI) due to Enterobacter cloacae are rare and often severe. The aim of this study is to describe cases with E. cloacae PJI.

Method

We conducted a retrospective and a monocentric study in an orthopedic unit where complex bone and joint infections are managed. From 2012 to 2016, we included patients with PJI which perioperative samples were positive with E. cloacae. We collected background, clinical, biological and microbiological data of the current infection, surgical and medical treatment, and the outcome of these patients.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 96 - 96
1 Dec 2015
Giordano G Gracia G Remi J Krin G Lourtet J Felice M Bicart-See A Gauthie L Marlin P Bonnet E
Full Access

To evaluate a innovate one stage procedure of the PJI knee treatment using computed assisted guidance. Our objectives; to increase the functional results by optimizing the anatomical joint reconstruction and to verifie if CAS help to simplifie and standardize these complex surgeries

It's a prospective, single surgeon study. Since septembre 2011, 41 patients treated for chronic knee PJI in a one stage revision (one of them had a ipsilateral chronic knee arthritis). For all of them, a computed assisted guidance, the ExactechGPS® system was used. This system offers the possibility to define specific profiles to performe primary TKA surgeries. A personnalized profile of revision was created.

All surgeries were performed with the same protocole; independently of the type of germ, with no use of tourniquet, no drainage by performing the same debridement procedure step by step and by using the same knee components

27 males, 14 female with 26 PJI of primary TKA, one infected unicompartimental prosthesis and 15 PJI of first revised TKA has been treated. The average age was 71 years old (55–87). The time of surgery was on average 135 mn (120 – 195 mn). The average time of hospitalization was 10 days (7–16). The average follow up was 20,9 months (6–47 months). The ROM were on average 114,7% (90°–130°), None post operative HKA outliers were reported.

3 patients presented a failure of the PJI treatment (one after a local open traumatism, one diabetic patient, one after a early revision for mechanical complication). None specific CAS complications and no failure of the CAS procedures are reported. As surgeon, CAS simplified the management of the bone loss after debridement and the control of the differents parameters (HKA, external femoral rotation, ligamentary balancing, lign joint…) by a real time feedback. we changed our practise by using more constraint condylar component instead hinge prostheses

With a rate of success of 92,7% at this follow up, the one stage option appears to be valided. Using CAS is a safe option with no specific complication. It increases the quality of the ROM, a earlier functional recovery and a better middle term clinical result. Both combined, It should be a optimal medicoeconomical solution.

compared revision using mechanical ancillary.