header advert
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 27 - 27
1 Oct 2012
Strachan R Konala P Iranpour F Prime M Amirthanayagam T Amis A
Full Access

Anatomical referencing, component positioning, limb alignments and correction of mechanical axes are essential first steps in successful computer assisted navigation. However, apart from basic gap balancing and quantification of ranges of motion, routine navigation technique usually fails to use the full potential of the registered information. Enhanced dynamic assessment using an upgraded navigation system (Brainlab V. 2.2) is now capable of producing enhanced ‘range of motion’ analysis, ‘tracking curves’ and ‘contact point observations’.

‘Range of motion analysis’ was performed simultaneously for both tibio-femoral and patella-femoral joints. Other dynamic information including epicondylar axis motion, valgus and varus alignments, antero-posterior tibio-femoral shifts, as well as flexion and extension gaps were simultaneously stored as a series of ‘tracking curves’ throughout a full range of motion. Simultaneous tracking values for both tibiofemoral and patellofemoral motion was also obtained after performing registration of the prosthetic trochlea. However, there seems to be little point in carrying out such observations without fully assessing joint stability by applying controlled force to the prosthetic joint.

Therefore, in order to fully assess ‘potential envelopes of motion’, observations have been made using a set of standardised simple dynamic tests during insertion and after final positioning of trial components. Also, such tests have been carried out before and after any necessary ligament balancing. Firstly, the lower leg was placed in neutral alignment and the knee put through a flexion-extension cycle. Secondly the test was repeated but with the lower leg being placed into varus and internal rotation. The third test was performed with the lower leg in valgus and external rotation. Force applied was up to the point where resistance occurred without any gross elastic deformation of capsule or ligament in a manner typical of any surgeon assessing the stability of the construct. Also a passive technique of using gravity to ‘Drop-Test’ the limb into flexion and extension gave useful information regarding potential problems such as blocks to extension, over-stuffing of the extensor mechanism and tightness of the flexion gap. All the definitive tests were performed after temporary medial capsular closure.

Ten total knee arthroplasties have been studied using this technique with particular reference to the patterns of instability found before, during and after adjustments to component positioning and ligament balancing. Marked intra-operative variation in the stability characteristics of the trial implanted joints has been quantified before correction. These corrections have been analysed in terms of change in translations, rotations and contact points induced by any such adjustments to components and ligament. Certain major typical patterns of instability have begun to be identified including excessive rotational and translational movements. Instability to valgus and external rotational stress was found in two cases and to varus and internal rotational stress in one case before correction. In particular, surprising amounts of edge loading in mid-flexion under stress testing has been identified and corrective measures carried out. Reductions in paradoxical tibio-femoral antero-posterior motion were also observed. Global instability and conversely tightness were also observed in early stages of surgery. Adjustments to component sizes, rotations, tibial slope angles and insert thickness were found to be necessary to optimise range of motion and stability characterisitics on an almost case-by-case basis. Two cases were identified where use of more congruent or stabilised components was necessary. Observation of quite marked loss of contact between tibia and femur was seen on the lateral side of the knee in deep flexion in several cases. Patellar tracking was also being observed during such dynamic tests and in two cases staged partial lateral retinacular releases were carried out to centre patellar tracking on the prosthetic trochlea.

Although numbers in this case series are small, it has been possible to begin to observe, classify and quantify patterns of instability intra-operatively using simple stress tests. Such enhanced intra-operative information may in future make it possible to create algorithms for logical and precise adjustments to ligaments and components in order to optimise range of motion, contact areas and stability in TKR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 84 - 84
1 Mar 2012
Molajo A Panchmatia J Konala P Strachan RK
Full Access

Statement of purpose

To analyse the distribution of osteoarthritis of the knee, to determine what proportion of patients may be suitable for a partial knee replacement and finally to assess the risk of wear progression.

Summary of methods used and results

The intra-operative articular surface mappings were collected for 250 consecutive patients undergoing knee arthroscopy. Patients were graded using the Outerbridge Classification. Radiographs including antero-posterior standing, postero-anterior flexion (Rosenberg), lateral and skyline views were graded (Kellgren and Lawrence) and compared with the arthroscopic findings.

13.3% of knees showed ‘isolated’ medial disease of Outerbridge Grade 3 or worse. Isolated lateral disease was noted in 1.4%, patello-femoral disease in 24.3%, bi-compartmental (Medial/PFJ) disease in 30.9% with tibio-femoral and tri-compartmental disease in 15.2%. The combination of lateral and patello-femoral disease was seen in 14.8%.

The mean age of patients with tri-compartmental disease (60.9 years) was greater than the mean age of those suffering with osteoarthritis limited to one or two compartments (54 years)

Radiological analysis revealed AP views had only 66% sensitivity and 73% specificity for the presence of Grade 3/4 lesions in the medial compartment. Rosenberg views had 73% sensitivity and 83% specificity. Skyline views had a sensitivity of 56% and 100% specificity.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 76 - 76
1 Mar 2012
Iranpour F Konala P Cobb JP Friederich N Hirschmann MT
Full Access

Introduction

SPECT/CT might be a promising diagnostic modality in patients with painful total knee arthroplasty. It was the purpose of our study to introduce a novel standardised SPECT/CT algorithm for assessing patients with painful primary total knee arthroplasty and to evaluate its clinical applicability and inter- and intra-observer variation and reliability.

Methods

A novel SPECT/CT localisation scheme, which consists of 9 tibial, 9 femoral and 4 patellar regions on standardised transverse, coronal, and sagittal slices was introduced. It was assessed in 18 consecutive patients with painful knees after total knee arthroplasty. The localisation and level of the tracer uptake on SPECT/CT were noted using a color coded 10 steps graded scale (0-100). The inter and intra-observer reliability were assessed. The femoral and tibial prosthetic component position was assessed in the CT images after 3D reconstruction and aligning them to standardised frames of reference. The average root mean square difference±standard deviations and ranges of these measured angles are presented along with the intraclass correlation coefficients for inter- and intraobserver reliability.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 433 - 433
1 Nov 2011
Strachan R Iranpour F Konala P Devadesan B Chia S Merican A Amis A
Full Access

Controversy still exists in the literature regarding efficacy and usefulness of CASN in knee arthroplasty. However, obsession with basic alignments and proper correction of mechanical axes fails to recognise the full future potential of CASN which seems to lie in enhanced dynamic assessment. Basic dynamics usually at least includes intraoperative assessment of limb alignments, flexion-extension gap balancing and simple testing through ranges of motion. However our upgraded CASN system (Brainlab) is also capable of enhanced assessment not only including the provision of data on initial to final alignments but also contact point observations. The system can also perform an enhanced ‘Range Of Motion’ (ROM) analysis including observation of epicondylar axis motion, valgus and varus, antero-posterior shifts as well as flexion and extension gaps. Tracking values for both tibiofemoral and patellofemoral motion have also been obtained after performing registration of the prosthetic trochlea.

Observations were then made using a set of standardised dynamic tests. Firstly, the lower leg was placed in neutral alignment and the knee put through a flexionextension cycle. Secondly the test was repeated but with the lower leg being placed into varus and internal rotation. The third test was performed with the lower leg in valgus and external rotation.

We have been able to carry out these observations in a limited case series of 15 total knee arthroplasties and have found it possible to observe and quantify marked intra-operative variation in the stability characteristics of the implanted joints before corrections have been made and final assessments performed. Indeed contact point observation has found several cases of edge loading before corrections have been made. Also ROM analysis has demonstrated the ability of the system in other cases to observe and then make necessary adjustments of implant positions and ligament balance which alter the amounts of antero-posterior and lateral translations. In this way paradoxical antero-posterior and larger rotational movements have been minimised. Cases where conversion to posterior stabilisation has been necessary have been encountered. Also patellar tracking has been observed during such dynamic tests and appropriate adjustments made to components and soft tissue balancing.

Although numbers in this case series are small, it has been possible to begin to observe, classify and quantify patterns of instability intra-operatively using simple stress tests. Such enhanced intra-operative information may in future make it possible to create algorithms for logical adjustments to ligament balance, component sizes, types and positions. In this way CASN becomes a more useful tool.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 388 - 388
1 Jul 2011
Davda K Konala P Iranpour F Hirschmann M Cobb J
Full Access

A robust frame of reference is required to accurately characterize pathoanatomy in the proximal femur and quantify the femoral head-neck relationship. A three dimensional (3D) femoral neck axis (FNA) could serve such a purpose, but has not yet been established in the current literature.

The primary aim of this study was to develop and evaluate a reliable method of determining the 3D femoral neck axis. Secondly, we wanted to quantify the translational relationship between the femoral head and neck in normal and cam type hips.

Pelvic computed tomographic scans (CT) and radiographs were retrieved from our database of patients who had undergone navigated hip surgery or CT colonography. All patients had given informed consent for their medical files and imaging to be used for research purposes, as approved by the institutional review board.

Pre-operative scans were performed using the Siemens Sensation 64 slice scanner (Siemens Medical Solutions, Erlangen, Germany). The Imperial Protocol developed at the authors’ orthopaedic unit was applied, allowing acquisition of Digital Imaging and Communications in Medicine (DICOM) files of 0.75mm thickness.

Normal and cam type hips (n=30) were identified for analysis. ‘Normal’ hips (n=15) were defined in asymptomatic patients with no previous history of hip disease, and, no obvious abnormality on radiographs or CT. The ‘cam’ hip type (n=15) was defined by the presence of an anterior osseous bump at the head-neck junction, and an alpha angle greater than 50° on hip radiographs.

DICOMs were converted to 3D stereolith (STL) images using validated commercial image processing and analysis software (3-Matics, Materialise Group, Leuven, Belgium).

In order to determine the 3D-FNA, a best fit sphere was applied to the femoral head with a root mean square error of less than 0.5mm. The border between sphere and femoral neck defined the head -neck junction. The bone surface was marked here (including the anterior bump in cam hips) and at the neck base, providing two anatomical rings that defined the superior and inferior limits of the femoral neck. The centre point of each ring was calculated. A line connecting these points defined the femoral neck axis, and was verified on a DICOM viewer in sagittal, axial and coronal planes. The offset between the femoral head centre and neck axis was measured.

The 3D image and axis were further analysed to examine the femoral head-neck relationship, using customized software developed at our institution and previously validated in previous research projects.

To standardize rotational alignment, the femoral neck was aligned vertically in two planes by creating an axis between the tip of the greater trochanter and the center of the lesser trochanter. The aligned proximal femur was viewed end on, and the version of the head relative to the neck determined by calculating the angle between the head centre and a vertical marker placed at the 12 o’clock position. Angles below 180° demonstrated anteversion, while those above 180° demonstrated retroversion.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 391 - 391
1 Jul 2011
Molajo A Konala P Ball S Iranpour F Nathwani D
Full Access

Reconstructive knee arthroplasty in patients with limb deformity can be a daunting and complex task. These patients are often younger and so post traumatic osteoarthritis poses a real challenge. In view of their relative youth, bone preservation would be favourable; however accurate implantation of components is essential. Formulation of a well calculated plan and accurate execution is essential for successful surgery.

We report on a novel method which combines 3D CT joint analysis and computer navigation to define the deformity present pre-operatively and determine whether the proposed reconstruction is feasible. If the reconstructive surgery is feasible, an accurate calculation the correction required is performed. The planned surgery is executed using computer aided navigation surgery.

Eight patients have benefited from the technique. Four patients presented with isolated medial compartment osteoarthritis and intact anterior cruciate ligament. These patients underwent 3D CT joint analysis and computer assisted navigation surgery to accurately implant unicondylar knee replacements.

Four Patients presented with two or three compartment disease. These patients underwent similar 3D CT analysis and navigated Total Knee Replacement.

The series demonstrates the merits of 3D CT joint analysis to accurately define deformity and therefore determine pre-operatively feasibility of corrective surgery proposed. The technique is then complimented by computer assisted navigation surgery to ensure the proposed surgical plan is accurately executed.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 629 - 633
1 May 2011
Hirschmann MT Konala P Amsler F Iranpour F Friederich NF Cobb JP

We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose.

A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p < 0.001).

3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 59 - 59
1 Jan 2011
Konala P Molajo A Panchmatia J Strachan R
Full Access

It is believed by some that knee radiographs may underestimate the extent of osteoarthritis. Often severe changes are noted at arthroscopic assessment despite the observation of preserved joint spaces on plain radiographs. This has important implications regarding the indications for different types of partial joint replacement if damage is underestimated.

Aims:

To determine the correlation if any between radiographic findings and arthroscopic findings.

To determine which radiographs are consistently useful for assessment of osteoarthritis and to determine the limitations.

To identify the proportions of patients with certain patterns of damage who might be suitable in the future for different types of partial replacement.

Methods and patient selection: The pre-operative radiographs and intra-operative articular surface mappings were collected for 100 consecutive patients undergoing prospectively audited outcome of arthroscopic debridement. All the patients examined were aged 40 and above with knee pain. The intra-operative findings and any work done (debridement of meniscal tears or cartilage flap tears) were also recorded on zoned articular maps and meniscal diagrams. The pre-operative radiographs (AP standing, lateral, Rosenberg and skyline views) were examined and graded using the Kellgren and Lawrence grading system.

Results: Correlations made between arthroscopic findings and AP standing views yielded a sensitivity of 72% and specificity of 64%. The positive predictive value was 91% and negative predictive value was 32%. Rosenberg views were better at predicting the presence of osteoarthritis (sensitivity 76%, specificity 88%, positive predictive value 97%, negative predictive value 44%). Skyline views were found to particularly unreliable in assessment of patello-femoral damage. Analysis of the actual patterns of articular damage found at arthroscopy did show that it is possible to identify cohorts of patients who may in future be suitable for different types of partial replacement.

Conclusions: Radiographs and in particular skyline views are limited in terms of sensitivity and specificity in the prediction of osteoarthritis. Rosenberg views offer better prediction of osteoarthritis compared with weight bearing AP radiographs. Arthroscopy carried out in any event for clinical indications appears to offer useful additional information regarding indications for future surgery.