header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 36 - 36
1 Apr 2019
Meftah M Boenerjous-Abel S Siddappa V White P Kirschenbaum I
Full Access

Background

Exparel (Pacira Pharmaceuticals, Parsippany, NJ, USA) is a long-acting liposomal Bupivacaine extended release compound that can be used as peri-articular injection (PAI) or regional nerve block. The purpose of this study was to compare the post-operative analgesic efficacy of Exparel as a single administration adductor canal block (ACB) varsus PAI.

Methods

From May 2016 to June of 2017, 70 patients with primary knee osteoarthritis undergoing unilateral knee replacement were prospectively randomized into two cohorts: 1) PAI (Exparel 266 mg (20 ml vial) with 20 ml of 0.5% bupivacaine HCl, and normal saline to a total volume of 120 ml); 2) ACB (Subsartorial saphenous nerve using Exparel 266 mg in 20 ml vial). All patents underwent spinal anesthesia with comprehensive pre-emptive and postoperative multimodal pain protocol. All opioids given were converted to morphine equivalents. Pain was recorded at 4 – 12 hrs (day of surgery), post-operative day (POD) 1, 2, and 3 after surgery.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 39 - 39
1 Apr 2019
Meftah M Kirschenbaum I
Full Access

Background

While tranexamic acid (TXA) has been well shown to reduce blood loss after joint replacement surgery, little is known regarding its effectiveness in obese patients. The aim of this study was to evaluate the effect of TXA changes in hematocrit and hemoglobin levels as well as incidence of packed red blood cell (pRBC) transfusions in obese patients undergoing total joint arthroplasty (TJA).

Material and Methods

Between January 2014 and May 2015, 420 consecutive primary joint replacements were performed by two surgeons at our institution. 157 patients (THA=29; TKA=128) were obese with a body mass index (BMI) greater than or equal to 30 kg/m2. Medical records were reviewed and identified that TXA was utilized in 85 (54.1%) arthroplasties [study group] and was compared to a consecutive series of 72 (45.9%) TJAs [control group]. TXA was given intravenously(IV) in two doses: (1) one gram prior to incision and (2) one gram at the time of femoral preparation in THA or prior to cementation in TKA. Changes in hemoglobin and hematocrit levels, number of pRBC transfusions, and occurrence of thrombolytic events were recorded.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 38 - 38
1 Apr 2019
Meftah M Kirschenbaum I
Full Access

Background

There is a recent interest and focus on reducing the length of stay and early discharge after total joint replacement (TJR). However, safety criteria for same-day (SD) or next-day (ND) home discharge are not well defined. We implemented a screening questionnaire to identify patients that qualify for early home discharge. The aim of this study was to assess the efficiency of this questionnaire and short-term outcomes including re-admission and peri-operative complications after TJR.

Methods

Between January 2016 and July 2017, 423 consecutive primary hip and knee arthroplasties were performed by the two senior surgeons at our institution. All cases were followed for a minimum of 3-month prospectively after institutional review board approval. Patients were divided based on using a pre-operative questionnaire to determine their disposition after surgery. Group 1 includes 121 cases as control and group 2 includes 302 cases with pre-operative questionnaire. Spinal anesthesia and multimodal pain management including peri-articular injection was used in all cases.

The pre-operative questionnaire (PQ, Swiftpath, Inc) included an overall score based on age, comorbidities, body mass index, physical assessment, motivation, comprehension, family support, home setup (i.e. easy access/stairs), proximity to the hospital and lack of serious barriers to early home discharge. Patients were divided into 3 categories based on the score: SD/ND home, regular home discharge and rehabilitation/subacute nursing facility (SNF) discharge. Length of stay (LOS), post-operative complications, readmissions, and discharge destination were assessed. Correlation the questionnaire score and outcomes were assessed.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 37 - 37
1 Apr 2019
Meftah M Kirschenbaum I
Full Access

Background

We identified several opportunities to significantly reduce cost for hip and knee arthroplasty procedures:

Customized instruments: by identifying the essential instruments for arthroplasty cases, we managed to have one universal tray for each case, and 3 specific trays from the implant manufacturing company.

Customized wrap-free, color-coded, stackable trays: by using a wrap-free trays, preparation time in central sterile, opening tray time in OR and turn-over time were reduced. Also, stackable trays were organized based on side and size, therefore only 2 trays needed to be used in each case.

Discounted implants: negotiated through optional case coverage with revision system and reps available as backup.

Optional rep coverage protocols: designed through process management of the operating room surgical staff and central sterile

Aim of the study was to measure the cost savings, efficacy, and outcomes associated with primary total hip and knee arthroplasty by implementing these protocol

Methods

This is a prospective study from January to October 2016 for selected primary total hip and knee arthroplasties were performed with the above protocols by 2 experienced arthroplasty trained surgeons, were followed for minimum 3 months. Initiating the cost saving protocols were achieved by re-engineering customized trays, discounted implants through optional case coverage (Sourced Based Selection of a Cooperating Manufacturer, MTD), and focused on process management of the staff training. Staff responsibilities were divided into 2 categories:

Familiarity of the instruments, implant, and techniques; trays set up and assurance of availability of the implants. These responsibilities were covered by a trained OR technician and the surgeon

Final verification of the accurate implants prior to opening the packaging. This was achieved by a trained OR nurse and the surgeon


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 5 - 5
1 Mar 2017
Meftah M Kirschenbaum I
Full Access

Introduction

Hip and knee device sales representatives (reps) can provide intra-operative guidance through their knowledge of the products, especially in complicated cases such as revision hip and knee arthroplasty. However, for an experienced arthroplasty surgeon in the majority of straightforward primary cases, the rep's presence may not be required for clinical decision-makings. With recent challenges in cost savings and bundle payments, hospitals and surgeons have focused on reducing the implant costs, among others, with a “repless” model. The aim of this study was to describe the process of utilizing this model, assess its efficacy, and analyze the cost savings in primary hip arthroplasty.

Methods

During the month of January 2016, 20 cases of primary, straightforward total hip arthroplasties were performed with the repless model by 2 experienced arthroplasty trained surgeons. All patients were followed prospectively for minimum 3 months. Prior to initiating the repless model, we focused on process management of the operating room with staff training and re-engineering of the trays to obtain a setup that included one hospital tray and one device company tray for each operation.

The responsibilities of the rep were divided into 2 categories for better management:

Familiarity of the instruments, implant, and techniques; trays set up and assurance of availability of the implants. These responsibilities were covered by a trained OR technician and the surgeon

Final verification of the accurate implants prior to opening the packaging. This was done by a trained OR nurse and the surgeon


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 3 - 3
1 Mar 2017
Meftah M White P Kirschenbaum I
Full Access

Background

While tranexamic acid (TXA) has been well shown to reduce blood loss after joint replacement surgery, little is known regarding its effectiveness in obese patients. The aim of this study was to evaluate the effect of TXA on packed red blood cell (PRBC) blood transfusion rates and change in hemoglobin (HGB) and hematocrit (HCT) for obese patients undergoing joint replacement at our institution.

Material and methods

Between January and December 2014, 117 consecutive primary joint replacements (THA n=23; TKA n=94) were performed in obese patients (BMI ≥ 30kg/m2) by two surgeons. Medical records were reviewed and identified that TXA was utilized in 45 (38.5%) arthroplasties. TXA was given intravenously (IV) in two doses: (1) one gram prior to incision and (2) one gram at the time of femoral preparation in THA or prior to cementation in TKA. Topical TXA was utilized in cases where IV TXA was contraindicated. PRBC transfusion rates, changes in HBG and HCT, and occurrence of thrombolytic events were recorded from hospital records.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 2 - 2
1 Mar 2017
Meftah M Kirschenbaum I
Full Access

Background

Post-operative deep venous thrombosis (DVT) and subsequent pulmonary embolism (PE) remain a serious complication after total joint replacement. Although with modern chemical and mechanical prophylaxis and rapid rehabilitation the rate of symptomatic DVT and PE has reduced, isolation of pre-operative DVT, especially in patients with prior history of DVT remains a challenge. The aim of this study was to assess the utility of pre-operative dopplers as a tool to screen and reduce DVT/PE rate in patients undergoing total joint replacement.

Methods

Between January 2014 and December 2014, 211 elective primary hip and knee arthroplasty were identified from our prospective institutional database as two consecutive cohorts (115 cases had pre-operative dopplers and 96 did not). All cases were performed by two adult reconstruction specialists. All primary total hip arthroplasties (THA) were non-cemented and all primary total knee arthroplasties (TKA) were cemented with similar implant and technique. In the first cohort, all cases underwent routine pre-operative doppler screening and in the control cohort, only patients with prior history of DVT or PE underwent pre-operative dopplers.

All patients with clinical symptoms of calf pain underwent post-operative dopplers. Patients were followed for a minimum of 3 month post-operatively. All emergency room (ER) visits for role out DVT were identified. No patient was lost to follow.