header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 69 - 69
1 Mar 2021
Ghani R Usman M Salar O Khan A Karim J Davis E Quraishi S Ahmed M
Full Access

Abstract

Objectives

Up to 19% of patients who undergo surgery for an acute hip fracture are readmitted to the hospital within three months of the index operation. We aimed to identify risk factors for unplanned clinic attendance, readmission, and mortality within the first 12 months postoperatively and subsequently determine if there is a role for routine follow-up.

Methods

Patients greater than 65 years old who underwent hip hemiarthroplasty using an uncemented Thompson implant for treatment of a traumatic non-pathological hip fracture were identified from a prospectively maintained database at a single institution between August 2007 and February 2011. Patient demographics, comorbidities, place of residence, mobility status, unplanned attendance to an orthopaedic clinic with symptoms relating to the respective limb, readmission, and mortality were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 21 - 21
1 Aug 2012
Khan A Surrao D Waldman S
Full Access

Bioreactors used in tissue engineering are mostly batch-fed with media added and removed periodically. Continuous flow bioreactors help increase ECM accumulation and cell proliferation, due to continuous flow of fresh media, thus, maintaining a steady extracellular nutrient environment. In previous work, we found chondrocytes cultured in continuous flow bioreactors with 20mM HEPES, accumulated considerably more matrix than static cultures. Hence, the objective of this study is to determine if NaHCO3 helps maintain a more physiological extracellular pH in the bioreactor, thus, enhancing ECM accumulation.

Cartilaginous tissue constructs were generated from isolated chondrocytes harvested from the metacarpal joints of 12-18 month old calves. Cells were seeded in high-density 3D cultures (2 million cells/construct). Constructs were cultivated in a continuous flow bioreactor, with and without 14 mM NaHCO3 supplemented media, for 5 weeks, at 37 degrees Celsius, 95% relative humidity and 5% CO2. After 5 weeks of culture the tissue weight, thickness, pH and ECM deposition were determined.

From the results obtained (Table 1), it is evident that chondrocytes cultured in the continuous flow bioreactor with 14mM NaHCO3 and 20mM HEPES, proliferated more extensively and produced more ECM than chondrocytes cultured in only 20mM HEPES. Additionally, the NaHCO3 constructs accumulated ECM in both the vertical (thickness) and horizontal (outgrowth) planes. The question then arises, are the effects mediated by improved buffering, or by addition of NaHCO3 itself. There was a significant difference between the pH of media with (pH 7.41) and without NaHCO3 (pH 6.95) supplementation, with no exposure to cells or tissue; when allowed to equilibrate with 5% CO2 at 37 degrees Celsius. However, there was little difference between the media after exposure to cells; after five weeks of culture in the bioreactor (Table 1). Thus, in the bioreactor with bicarbonate present, because of increased cell number and activity, the pH fell 0.54 pH units during the 7 hour residence time in comparison to the bioreactor with no bicarbonate supplementation. With no NaHCO3 supplementation, the extracellular pH of the medium fed to the cells was never above pH 7.0 (Table 1); low pH could account, at least in part, for lower ECM and cell numbers.