Aim

The aim of this study was to investigate the clinical relevance of an isolated positive sonication fluid culture (SFC) in patients who underwent revision surgery of a prosthetic joint. We hypothesized that cases with a positive SFC have a higher rate of infection and prosthesis failure during follow-up compared to controls with a negative SFC.

Method

This retrospective multicentre observational study was performed within the European Study Group of Implant-Associated Infections (ESGIAI). All patients who underwent revision surgery of a prosthetic joint between 2013 and 2019 and had a minimum follow-up of 1 year were included. Patients with positive tissue cultures or synovial fluid cultures were excluded from the study.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 50 - 50
1 Oct 2022
Pardos SL No LR Arderiu A Redó MLS Prieto DP Junyent JG Verdie LP Fabrego AA Prim N Cerrato SG
Full Access

Aim

Vancomycin is frequently used for bone and joint infections (BJI) because of the main role of Gram-positive bacteria as potential causal agents. It is crucial to achieve optimal vancomycin plasma concentrations since the first day to maximize treatment clinical and microbiological efficacy. The aim was to describe the patients’ profile that are more likely to achieve an optimal pharmacokinetic/pharmacodynamics (PK/PD) vancomycin target in the first therapeutic drug monitoring (TDM) sample.

Methods

Retrospective study (March 2018-January 2022) in a university hospital including all patients treated with vancomycin for a BJI and undergoing TDM. Initial dose (1g/8-12h) was selected by the responsible clinician. Vancomycin plasma concentrations were obtained pre-dose (Cmin,ss) and 60-minutes after the infusion on day 2 of treatment. Global exposure measured by the area under the curve of plasma concentrations during 24h (AUC024h) was estimated using a bicompartmental PK model.

An AUC024h/CMI=400–600mg*h/L was considered optimal, <400 infratherapeutic and >600 supratherapeutic, based on recent guidelines, and patients were classified into these 3 groups. A value of CMI=1 mg/L was considered, following guidelines recommendations.

Categorial data: percentages and quantitative data as mean (standard deviation).