header advert
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 399 - 403
1 Mar 2011
Griffiths D Gikas PD Jowett C Bayliss L Aston W Skinner J Cannon S Blunn G Briggs TWR Pollock R

Between 1997 and 2007, 68 consecutive patients underwent replacement of the proximal humerus for tumour using a fixed-fulcrum massive endoprosthesis. Their mean age was 46 years (7 to 87). Ten patients were lost to follow-up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumor Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS) at a mean follow-up of five years and 11 months (one year to ten years and nine months). The mean MSTS score was 72.3% (53.3% to 100%) and the mean TESS was 77.2% (58.6% to 100%).

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This subgroup had a mean MSTS score of 77.7% and a mean TESS of 80.0%. The dislocation rate for the original prosthesis was 25.9; none of the patients with the new liner had a dislocation at a mean of 14.5 months (12 to 18).

Endoprosthetic replacement for tumours of the proximal humerus using this prosthesis is a reliable operation yielding good results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with a new constrained humeral liner, which reduces the risk of dislocation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 499 - 499
1 Sep 2009
Griffiths D Pollock R Gikas P Bayliss L Jowett C Briggs T Cannon S Skinner J
Full Access

We retrospectively studied 67 patients who underwent proximal humeral replacement with the Bayley-Walker prosthesis, for tumour of the proximal humerus between 1997 and 2007. Of the 67 patients 10 were lost to follow up. Of the 41 surviving patients, function was assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS) questionnaire.

4 of the 41 patients received the new Bayley-Walker ‘captured’ proximal humeral replacement. The mean age was 46 years (7–87). The mean MSTS score at follow-up was 72.0 % and the mean TESS score was 77.2 %. The sub-group of 4 pts who received the new captured prosthesis had a mean MSTS score of 77.7 %. There was no mechanical failure of any prostheses in the follow up period.

Endoprosthetic replacement for tumour of the proximal humerus with the Bayley-Walker prosthesis, is a reliable operation yielding reasonable functional results and good long-term prosthesis survivorship. The performance of this prosthesis is expected to improve further with the new ‘captured’ prosthesis.