header advert
Results 1 - 10 of 10
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 1 - 1
8 Feb 2024
Gunia DM Pethers D Mackenzie N Stark A Jones B
Full Access

NICE Guidelines suggest patients should be offered a Total Hip Replacement (THR) rather than Hemiarthroplasty for a displaced intracapsular hip fracture. We investigated outcomes of patients aged 40–65 who received a THR or Hemiarthroplasty following a traumatic intracapsular hip fracture and had either high-risk (Group 1) or low-risk (Group 2) alcohol consumption (>14 or <14 units/week respectively).

This was a retrospective study (April 2008 – December 2018) evaluating patients who underwent THR or Hemiarthroplasty in Greater Glasgow and Clyde. Atraumatic injuries, acetabular fractures, patients with previous procedures on the affected side and those lost to follow up were excluded. Analysis of length of admission, dislocation risk, periprosthetic fractures, infection risk, and mortality was conducted between both cohorts.

Survival time post-operatively of Group 1 patients with a THR (61.9 months) and Hemiarthroplasty (42.3 months) were comparable to Group 2 patients with a THR (59 months) and Hemiarthroplasty(42.4 months). Group 1 patients with THR had increased risk of dislocation (12.9%; p=0.04) compared to those that received Hemiarthroplasty (2.5%). Group 1 Hemiarthroplasty patients had increased wound infection risk (11.6%) compared to Group 2 (3.7%).

In conclusion, we found that amongst our population the life expectancy of a post-operative patient was short irrespective of whether they had high or low-risk alcohol consumption. A hip fracture may represent increased frailty in our study population. The Group 1 THR cohort presented a higher risk of hip dislocation and periprosthetic fracture. With this in mind, Hemiarthroplasty is a more cost-effective and shorter operation which produces similar results.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 10 - 10
1 Feb 2020
Clark A Hounat A MacLean A Jones B Blyth M
Full Access

We report on the 5 year results of a randomized study comparing TKR performed using conventional instrumentation versus electromagnetic computer-assisted surgery.

This study analysed patient reported outcome measures (PROMs) at 5 years utilising the American Knee Society Score (AKSS), Oxford Knee Score (OKS), the Short Form 36 score and range of motion (ROM). Of the 200 patients enrolled 125 completed 5 year follow up, 62 in the navigated group and 63 in the conventional group. There were 28 deceased patients, 29 withdrawals and 16 lost to follow-up.

There was improvement in clinical function in most PROMs from 1-5 year follow up across both groups. OKS improved from a mean of 26.6 (12–55) to 35.1 (5–48). AKSS increased from 75.3 (0–100) to 78.4 (−10–100), SF36 from 58.9 (2.5–100) to 53.2 (0–100). ROM improved by an average 7 degrees from 110 degrees to 117 degrees (80–135). There was no statistically significant difference in PROMs between the groups at 5 years.

Patients undergoing revision surgery were identified from the dataset and global PACS. There were no revisions within 5 years in the navigated group and 3 revisions in the conventional group, two for infection and one for mid-flexion instability, giving an all cause revision rate of 3.06% at 5 years for this group.

There appears to be no significant advantage in clinical function for patients undergoing TKR for OA of the knee with electromagnetic navigation when compared to conventional techniques. There may be an advantage in reducing early revision rates using this technology.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 12 - 12
1 Feb 2020
Giebaly D Vats A Marshall C Leach B Rooney B McConnachie A Jones B Blyth M
Full Access

MOXIMED KineSpring® Knee Implant System is an Orthopaedic device designed for younger or highly active patients with osteoarthritis. The device is placed under the skin, is attached to the tibia and femur, and contains springs which help limit some of the forces that are transmitted through the knee during activities such as walking or running and thereby relieve pain that may be experienced by patients with early arthritis of the knee. The aim of this study is to determine the long term safety and efficacy of the KineSpring knee implant system.

This is a prospective case series involving two centres in Glasgow. 29 patients (mean age of 45.1 years and range 18-65 years) were recruited into the study between 2011 and 2016. The Primary outcome measure was Oxford knee score (OKS) at 2, 5 and 10 years post-operatively. Secondary outcome measures include device related complications and survival, patient reported functional outcome measures, patient satisfaction, pain levels and change in radiographic classification of osteoarthritis

At 2-year follow-up, 7 implants were removed (74.1% survival). Complications include deep infection, requiring removal in 1 patient, 2 implant failures requiring removal and one spring breakage. In comparison to pre-operative measures there was an improvement in the pain (3.58 vs. 5.20, p=0.02), stiffness (4.16 vs. 4.47, p=0.6) and OKS (32.4 vs. 36.9, p=0.03).

The KineSpring improves overall pain, stiffness and functional outcome at 2 years following surgery, however there was a high rate of removal and further long-term follow up analysis is required regarding its effectiveness.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_17 | Pages 12 - 12
1 Dec 2015
Torkington M Davison M Wheelwright E Jenkins P Lovering A Blyth M Jones B
Full Access

Cephalasporin antibiotics have been commonly used for prophylaxis against surgical site infection. To prevent Clostridium difficile, the preferential use of agents such as flucloxacillin and gentamicin has been recommended. The aim of this study was to investigate the bone penetration of these antibiotics during hip and knee arthroplasty, and their efficacy against Staphylococcus aureus and S. epidermidis.

Bone samples were collected from 21 patients undergoing total knee arthroplasty (TKA) and 18 patients undergoing total hip replacement (THA). The concentration of both antibiotics was analysed using high performance liquid chromatography. Penetration was expressed as a percentage of venous blood concentration. The efficacy against common infecting organisms was measured using the epidemiological cut-off value for resistance (ECOFF).

The bone penetration of gentamicin was higher than flucloxacillin. The concentration of both antibiotics was higher in the acetabulum than the femoral head or neck (p=0.007 flucloxacillin; p=0.021 gentamicin). Flucloxacillin concentrations were effective against S. aureus and S. epidermis in all THAs and 20 (95%) TKAs. Gentamicin concentrations were effective against S.epidermis in all bone samples. Gentamicin was effective against S. aureus in 11 (89%) femoral samples. Effective concentrations of gentamicin against S. aureus were only achieved in 4 (19%) femoral and 6 (29%) tibial samples in TKA.

Flucloxacillin and gentamicin was found to effectively penetrate bone during arthroplasty. Gentamicin was effective against S. epidermidis in both THA and TKA, while it was found to be less effective against S. aureus during TKA. Bone penetration of both antibiotics was less in TKA than THA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 6 - 6
1 Sep 2013
Robinson P Anthony I Kumar S Jones B Stark A Ingram R
Full Access

This study assesses the incidence of noise in ceramic on ceramic (COC) bearings compared to metal on polyethylene (MOP) bearings. Noise after MOP implants has rarely been studied and they never been linked to squeaking.

We have developed a noise characterising hip questionnaire and sent it along with the Oxford Hip Score (OHS) to 1000 patients; 509 respondents, 282 COC and 227 MOP; median age 63.7 (range 45–92), median follow up 2.9 years (range 6–156 months).

47 (17%) of the COC patients reported noise compared to 19 (8%) of the MOP patients (P=0.048). 9 COC and 4 MOP patients reported their hip noise as squeaking. We found the incidence of squeaking in the COC hips to be 3.2% compared to 1.8% in the MOP hips. Overall, 27% patients with noise reported avoiding recreational activities because of it and patient's with noisy hips scored on average 4 points less in the OHS (COC: P=0.04 and MOP: P =0.007).

This is the first study to report squeaking from MOP hip replacements. We therefore believe the squeaking hip phenomenon is not exclusive to hard bearings. Surprisingly, only a small proportion of patients described nose from their as a ‘squeak’. Noisy hip implants may have social implications, and patients should be aware of this. We have shown a relationship between noise and a lower OHS. However, longer follow-up and further study is needed to link noise to a poorly functioning implant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 7 - 7
1 Sep 2013
Lavery J Blyth M Jones B Anthony I
Full Access

To validate the Modified Forgotten Joint Score (MFJS) as a new patient-reported outcome measure (PROM) in hip and knee arthroplasty (THR/TKR) against the UK's gold standard Oxford Hip and Knee Scores (OHS/OKS).

The MFJS is a new assessment tool devised to provide a greater discriminatory power, particularly in well performing patients. It measures an appealing concept; the ability of a patient to forget about their artificial joint in everyday life.

Postal questionnaires were sent out to 400 THR and TKR patients who were 1–2 years post-op. The data collected from the 212 returned questionnaires was analysed in relation to construct and content validity. 77 patients took part in a test-retest repeatability assessment.

The MFJS proved to have an increased discriminatory power in high-performing patients in comparison to the OHS and OKS, highlighted by its more normal frequency of distribution and reduced ceiling effects. 30.8% of patients (n=131) achieved excellent OHS/OKS scores of 42–48 this compared to just 7.69% of patients who achieved a proportionately equivalent MFJS score of 87.5–100. The MFJS proved to have an increased test-retest repeatability based upon its intra-class correlation coefficient of 0.97 compared to the Oxford's 0.85.

The MFJS provides a more sensitive tool in the assessment of well performing hip and knee arthroplasties in comparison to the OHS/OKS. The MFJS tests the concept of awareness of a prosthetic joint, rather than pain and function and therefore should be used as adjunct to the OKS/OHS.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 11 - 11
1 May 2013
Donaldson D Torkington M Anthony I Blyth M Jones B
Full Access

The longitudinal midline and medial-parapatellar incision are commonly used in Total Knee Arthroplasty (TKA). Medial-parapatellar incision n offers a smaller wound, avoids creation of thin skin flaps and easier exposure in obese patients. This incision creates a lateral skin flap which may be subject to poor blood supply and delayed wound healing.

We undertook a Randomised Controlled Trial (n=20) comparing midline and medial-parapatellar incisions. Cutaneous blood-flow was measured using a Doppler Imager. Interstitial fluid measurements for lactate, pyruvate, lactate/pyruvate ratio and glucose were obtained from subcutaneous microdialysis catheters. Wound cosmesis was graded and skin sensation tested.

Immediately post-op there was no significant difference in subcutaneous blood flow, but by day 3 patients with medial-parapatellar incisions showed greater bloodflow than midline incisions, particularly on the medial side (387 vs 278units p=0.148). At both day 1 and 3 post-op the lateral flap of the medial parapatellar incision showed decreased blood flow compared to the medial side, though these failed to reach significance. In contrast the midline incision showed no discernable difference in blood flow between the medial and lateral flaps. Concentrations of subcutaneous glucose increased from 4 hours post-op in the midline group, returning to baseline by 24hours. In contrast, the parapatellar group remained at base line throughout. Lactate concentrations increased over time in both groups peaking at 12hours post-op. No difference was noted between incision types with regard to wound cosmesis.

We conclude that the use of a medial-parapatellar incision results in only minimal biochemical changes, which are unlikely to alter wound healing. Medial-parapatellar incision is therefore a safe alternative to a midline incision and can be utilised in appropriate complex cases to aid surgical exposure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 499 - 499
1 Sep 2012
Bell S Young P Drury C Blyth M Jones B Mclean A
Full Access

Introduction

Total knee arthroplasty is an established and successful operation. In up to 10% of patients who undergo total knee arthroplasty continue to complain of pain [1]. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful total knee arthroplasty.

Methods

We reviewed 56 painful total knee replacements and compared these to 59 pain free total knee replacements. Datum gathered from case notes and radiographs using a prospective orthopaedic database to identify patients. The age, sex, preoperative Oxford score and BMI, postoperative Oxford score and treatments recorded. The CT information recorded was limb alignment, tibial component rotation, femoral component rotation and combined rotation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 44 - 44
1 Sep 2012
Blyth M Jones B Smith J Rowe P
Full Access

Electromagnetic navigation versus conventional Total Knee Arthroplasty: Clinical improvements Optical and electromagnetic (EM) tracking systems are widely used commercially. However in orthopaedic applications optical systems dominate the market. Optical systems suffer from deficiencies due to line of sight. EM trackers are smaller but are affected by metal. The accuracy of the two tracker systems has been seen to be comparable1. Recent advancements in optical navigated TKA have shown improved overall limb alignment, implant placement and reduce outliers when compared to conventional TKA2-4.

This study is the first RCT to compare EM and conventional TKA. Two groups of 100 patients underwent TKA using either the EM navigation system or the conventional method. Frontal, sagittal and rotational alignment was analysed from a CT scan. Clinical scores including Oxford Knee Score (OKS) and Knee/Function American Knee Society Score (AKSS) were recorded pre-op, and at 3 and 12 months post-op. 3 month data presented includes 180 patients (n = 90). The 12 months data presented includes 140 (n = 70).

The two groups had similar mean mechanical axis alignments (EM 0.31o valgus, conventional 0.15o valgus). The mechanical axis alignment was improved in the EM group with 92% within +/-3o of neutral compared to 84% of the conventional group (p = 0.90). The alignment of the EM group was improved in terms of frontal femoral, frontal tibial, sagittal femoral, sagittal tibial and tibial rotation alignment. However, only the sagittal femoral alignment was significantly improved in the EM group (p = 0.04). Clinically, both TKA groups showed significant improvements in OKS and AKSS scores between both pre-op to 3 month post-op and 3 months to 12 months post-op (p<0.001). The OKS and the AKSS knee score for the EM group was significantly better at 3 months post-op (OXS p = 0.02, AKSS knee p = 0.04). However there was no difference between the groups at 12 months. The mean pre-op range of motion (ROM) for both groups was 105o. This decreased to 102o in the EM group and 99o in the conventional group at 3 months. There was a significant improvement at 12 months post-op, EM = 113o (p = 0.012) and conventional = 112o (p = 0.026). There was no significant difference in ROM between the two groups at 3 or 12 months post-op.

Therefore the alignment outcome of the EM TKA group was improved compared to the conventional group. The EM group also showed clinical improvements at 3 months post-op however these were not seen again at 12 months post-op. ROM was seen to decrease at 3 months post-op but then significantly improve by 12 month post-op.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIII | Pages 9 - 9
1 Jul 2012
Russell D Fogg Q Mitchell CI Jones B
Full Access

The superficial anterior vasculature of the knee is variably described; most of our information comes from anatomical literature. Descriptions commonly emphasise medial-dominant genicular branches of the popliteal artery. Describing the relative contribution of medial and lateral vessels to the anastomotic network of the anterior knee may help provide grounds for selecting one of a number of popular incisions for arthrotomy.

The aim of this study is to describe the relative contribution of vessels to anastomoses supplying the anterior knee.

Cadaveric knees (n = 16) were used in two cohorts. The first cohort (n = 8) were injected at the popliteal artery with a single colour of latex, and then processed through a modified diaphanisation technique (chemical tissue clearance) before final dissection and analysis. This was repeated for the second cohort, but with initial dissection to identify potential source vessels at their origin. Each source vessel was injected with a different colour of latex. The dominant sources were determined in each specimen.

The majority of the specimens (n = 13; 81%) demonstrated that an intramuscular branch though the vastus medialis muscle was the dominant vessel. Anastomoses were most common over the medial side of the knee, both superiorly and inferiorly (3-5 anastomoses in all cases). Anastomosis over the lateral knee was infrequent (1 anastomosis in 1 specimen).

The results suggest that anterior vasculature of the knee is predominately medial in origin, but not from the genicular branches as previously described. This network of vessels found in the anterior knee is thought to be the main supply to the patella, extensor apparatus, anterior joint capsule and skin.

Optimum placement of incision for arthrotomy is a subject of debate. Considering the main blood supply to the anterior knee may help in choosing a particular approach.