header advert
Results 1 - 5 of 5
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1138 - 1143
1 Sep 2019
MacDonald DRW Caba-Doussoux P Carnegie CA Escriba I Forward DP Graf M Johnstone AJ

Aims

The aim of this study was to compare the incidence of anterior knee pain after antegrade tibial nailing using suprapatellar and infrapatellar surgical approaches

Patients and Methods

A total of 95 patients with a tibial fracture requiring an intramedullary nail were randomized to treatment using a supra- or infrapatellar approach. Anterior knee pain was assessed at four and six months, and one year postoperatively, using the Aberdeen Weightbearing Test – Knee (AWT-K) score and a visual analogue scale (VAS) score for pain. The AWT-K is an objective patient-reported outcome measure that uses weight transmitted through the knee when kneeling as a surrogate for anterior knee pain.


Bone & Joint Research
Vol. 5, Issue 10 | Pages 481 - 489
1 Oct 2016
Handoll HHG Brealey SD Jefferson L Keding A Brooksbank AJ Johnstone AJ Candal-Couto JJ Rangan A

Objectives

Accurate characterisation of fractures is essential in fracture management trials. However, this is often hampered by poor inter-observer agreement. This article describes the practicalities of defining the fracture population, based on the Neer classification, within a pragmatic multicentre randomised controlled trial in which surgical treatment was compared with non-surgical treatment in adults with displaced fractures of the proximal humerus involving the surgical neck.

Methods

The trial manual illustrated the Neer classification of proximal humeral fractures. However, in addition to surgical neck displacement, surgeons assessing patient eligibility reported on whether either or both of the tuberosities were involved. Anonymised electronic versions of baseline radiographs were sought for all 250 trial participants. A protocol, data collection tool and training presentation were developed and tested in a pilot study. These were then used in a formal assessment and classification of the trial fractures by two independent senior orthopaedic shoulder trauma surgeons.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 4 - 4
1 Apr 2013
Munro C Escriba I Graf M Johnstone AJ
Full Access

This ongoing prospective RCT compares two surgical approaches with respect to accuracy of guidewire and tibial nail position.

29 patients with tibial fractures were randomised to semi-extended (SE) or standard (S) approaches of tibial nail insertion. Fluoroscopy obtained guidewire and final nail position. The SE approach is more proximal with the guidewire inserted posterior to the patella, theoretically allowing more accurate wire and nail placement.

Measurements were taken in both planes of the nail and guidewire to determine deviation from optimum angle of insertion (relative to the long axes of the tibial shaft).

14 and 15 patients were treated with semi-extended and standard approaches respectively.

The semi-extended approach results in better guidewire and nail placement in both planes with mean deviation from the optimal angle of insertion as below:

Guidewire AP 4.5° (SE) versus 4.04° (S) Lateral 24.59° (SE) versus 33.36° (S)

Nail AP 3.21° (SE) versus 3.68° (S) Lateral 17.73° (SE) versus 24.04° (S)

Anterior knee pain may be due to excessive anterior placement of the nail. We assessed anterior placement of the guidewire and nail in the lateral plane. This was expressed as a percentage from the anterior cortex of the tibia. Mean results are below:

Guidewire 9.7% (SE) versus 9.3% (S)

Nail 19.5% (SE) versus 16.3% (S)

Semi-extended nailing may allow for better guidewire position and as such nail placement. This may reduce anterior knee pain.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 38 - 38
1 Apr 2013
Johnstone A Johnstone AJ Elliott KG
Full Access

Failure to treat acute compartment syndrome (ACS) early leads to significant morbidity. Current practice depends on using clinical signs and intracompartmental pressure (ICP) monitoring to diagnose the syndrome but there is still debate regarding their accuracy and interpretation.

Patients admitted with injuries at risk of ACS underwent intramuscular (IM) pH and ICP monitoring combined with regular clinical assessment. Fasciotomies were performed on those with clinical and/or pressure based evidence of ACS. All patients were subsequently assessed for evidence of a missed ACS at at 6 & 12 months.

Of the 62 patients, 51 completed the protocol and were included in the analysis. They were divided into 2 groups: those who had ACS, either initially (fasciotomies; 13), or diagnosed at follow up (no fasciotomies; 7), and those with no evidence of ACS (31).

The sensitivity and specificity for the worst values for each variable were calculated and receiver operator characteristic (ROC) curves generated. The area under the curve for pH was 0.92, 0.73 for absolute pressure and 0.59 for delta pressure. To achieve a sensitivity of 95%, an absolute pressure of >30mmHg was 30% specific, a delta pressure of <33mmHg was 27%, while IM pH of 6.38 was 80% specific.

This study highlights the issues concerning current diagnostic methods for ACS. By comparison, IM pH radically out performed both the highest ICP and the lowest delta pressure, identifying patients early and accurately.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 11 - 11
1 Feb 2013
Wohlgemut JM Medlock G Stevenson IM Johnstone AJ
Full Access

Magnetic resonance imaging (MRI) validation of a novel method of assessing Distal Radial Fracture (DRF) reduction using the hypothesised constant relationship between the dorsal radial cortex (DC) and the superior pole of the lunate (SL).

MRI scans of 28 normal wrists were examined. Scans included the distal third of the radius to the proximal carpal row. Beginning 5cm proximal to the distal radius articular surface, a line was superimposed upon the DC extending distally through the metaphyseal flare.

Lunate height (LH) and distance from the DC line to the SL (DC-SL) were measured at 5-degree rotational increments around the radial shaft central axis to a total of 30 degrees of supination and pronation (S+P). The DC-SL/LH ratio was compared to 0 degrees (anatomical lateral) using the two-tailed paired student t-test.

There was no significant difference in DC-SL:LH between 0 degrees of rotation and any 5-degree increment up to 30 degrees of S+P (lowest p=0.075). The DC line lay consistently dorsal to the SL.

A constant DC-SL relationship exists with up to 30 degrees of S+P. This reference can be quickly and accurately used to assess DRF reduction in poorly-taken films with malrotation up to 30 degrees from anatomical lateral. Research comparing DC-SL distance with volar tilt to assess DRF reduction is needed.