header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 4 - 4
1 Feb 2017
Anderson C Gustke K Roche M Golladay G Jerry G Elson L
Full Access

Total knee arthroplasty (TKA) patients are consistently reported to be less satisfied than total hip arthroplasty (THA) patients. A patient's perception of success of his/her own total knee is dictated by their levels of post-operative pain and function, and many return to follow-up visits with inexplicable pain and stiffness that contradict favorable radiographic results. Several of these chief complaints that contribute to dissatisfaction are associated with soft-tissue imbalance. Therefore, in an effort to thoroughly understand the post-operative impact of soft-tissue balance on satisfaction, a multicenter study was conducted to evaluate the satisfaction outcomes of quantifiably balanced patients.

In this study, 102 sensor-assisted patients were followed out to 3 years. The intraoperative devices used in this study project kinetic loading (lbf.) and center of load location data, in real-time, to a screen. Because of the wireless nature of the intraoperative sensors, the patella can be reduced, and kinematic data can be evaluated through the range of motion. The target balance window that was used in this study has been previously reported in literature and includes: 1) a mediolateral differential of 15 lbf., through the ROM, and 2) Sagittal plane stability as determined by a posterior drawer analysis. A robust, face-validated satisfaction survey was administered at 3-year follow-up and included 7 questions with answers on a 5-point Likert scale.

At 3 years, post-operatively, 97.2% of this patient group reported being “satisfied” to “very satisfied” with their procedure, in comparison to the 81% average TKA satisfaction reported in literature (df = 11). The comparative literature included annual satisfaction intervals from 1 to 5 years (n = 33,775) which is comparable to the interval reported in this patient group. The sensor-assisted patient group exhibited a 16% increase in the proportion of satisfaction over what is currently reported in the comparative literature (p = 0.001).

Despite the success rate of TKA, unfavorable patient-reported satisfaction continues to present a problem for operative recipients and surgeons. Because satisfaction is dependent upon several variables – including pain, function, and activity levels – the satisfaction survey used in this study represents a more accurate account of patient perception than many traditional surveys. It was shown that sensor-balanced TKA patients exhibited a 16% increase in the proportion of those reporting being “satisfied” to “very satisfied”, over the average satisfaction reported in literature. Allowing the surgeon to quantitatively balance the soft-tissue envelope, dynamically, has continued to a significant decrease in the proportion of dissatisfaction.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 356 - 356
1 Dec 2013
Jerry G Dounchis J
Full Access

Introduction

Accurate alignment of components in total knee arthroplasty (TKA) is a known factor that contributes to improvement of post-operative kinematics and survivorship of the prosthetic joint. Recently, CAOS has been introduced into TKA in effort to reduce positioning variability that may deviate from the mechanical axis. However, literature suggests that clinical outcomes following TKA with CAOS may not present a significant improvement from traditional methods of implantation. This would infer that achieving correct alignment, alone, might be insufficient for ensuring an optimal reconstruction of the joint. Therefore, this study seeks to evaluate the importance of soft-tissue balancing, through the quantification of joint kinetics collected with intraoperative sensors, with or without the combined use of CAOS.

Methods

Seven centers have contributed 215 patients who have undergone primary TKA with the use of intraoperative sensors. Of the 7 surgeons contributing patients to this study, 3 utilize CAOS; 4 utilize manual techniques. Along with standard demographic and surgical data being collected as per the multicenter study protocol, soft-tissue release techniques and medial-lateral intercompartmental loads—as indicated by the intraoperative sensors—were also captured pre- and post-release. “Optimal” balance was defined as a medial-lateral load difference of ≤ 15 lbs. A chi-squared analysis was performed to determine if the percentage of soft-tissue release was significantly different between the two groups: patients with CAOS, and patients without CAOS.