header advert
Results 1 - 20 of 31
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 283 - 288
1 Feb 2017
Hughes A Heidari N Mitchell S Livingstone J Jackson M Atkins R Monsell F

Aims

Computer hexapod assisted orthopaedic surgery (CHAOS), is a method to achieve the intra-operative correction of long bone deformities using a hexapod external fixator before definitive internal fixation with minimally invasive stabilisation techniques.

The aims of this study were to determine the reliability of this method in a consecutive case series of patients undergoing femoral deformity correction, with a minimum six-month follow-up, to assess the complications and to define the ideal group of patients for whom this treatment is appropriate.

Patients and Methods

The medical records and radiographs of all patients who underwent CHAOS for femoral deformity at our institution between 2005 and 2011 were retrospectively reviewed. Records were available for all 55 consecutive procedures undertaken in 49 patients with a mean age of 35.6 years (10.9 to 75.3) at the time of surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 111 - 111
1 Jan 2017
O'Callaghan J Clark D Jackson M LIvingstone J Mitchell S Atkins R
Full Access

The implementation of knee arthrodesis has become synonymous with limb salvage in the presence of chronic sepsis and bone loss around the knee. This can be seen in failed trauma surgery or knee arthroplasty as an alternative to trans-femoral amputation. There is no prior literature assessing which factors affect knee arthrodesis using external fixation devices.

Sixteen consecutive patients (four women and twelve men) made up of eleven infected knee implants, three internal fixations of the tibial following fractured tibial plateau as well as 2 infected native joints were identified. The mean age at initial surgery was 56 years (range 25 to 82 years). All procedures were performed under the direct supervision of the limb reconstruction teams using a standard protocol with either a Taylor spatial frame or Ilizarov frame. The patient records, microbiology results and radiographs of all patients who underwent knee arthrodesis at this institution between 1999 and 2010 were reviewed.

Of the 16 patients in this study knee fusion occurred in eleven patients (69%). The five patients where arthrodesis failed all had significant bone loss on the pre-operative radiographs and confirmed at surgery. We found a relationship between a significant infection of the knee with MRSA and failure to fuse. Three of the five patients had MRSA isolated from inside the knee at some stage during their treatment.

The five patients where fusion failed were on average older (mean age 63 years against 51 years) and had more extensive bone loss. Those who failed to fuse had more co-morbidities. We would conclude that where there is little or no bone loss, arthrodesis of the knee can be reliably achieved with the use of circular frame fixation. A greater number of negative factors also prolongs the amount of time spent in the external fixator. The presence of significant bone loss, infection, increased age and multiple co-morbidities requires careful evaluation and consideration of trans-femoral amputation as an alternative.


Bone & Joint 360
Vol. 4, Issue 4 | Pages 2 - 7
1 Aug 2015
Nicol S Jackson M Monsell F

This review explores recent advances in fixator design and used in contemporary orthopaedic practice including the management of bone loss, complex deformity and severe isolated limb injury.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 12 - 12
1 Jul 2014
Fenton P Hughes A Howard D Atkins R Jackson M Mitchell S Livingstone J
Full Access

Percutaneous grafting of non-union using bone marrow concentrates has shown promising results, we present our experience and outcomes following the use of microdrilling and marrowstim in long bone non-unions.

We retrospectively reviewed all patients undergoing a marrowstim procedure for non-union in 2011–12. Casenotes and radiographs were reviewed for all. Details of injury, previous surgery and non-union interventions together with additional procedures performed after marrowstim were recorded for all patients. The time to clinical and radiological union were noted.

We identified 32 patients, in sixteen the tibia was involved in 15 the femur and in one the humerus. Ten of the 32 had undergone intervention for non-union prior to marrowstim including 4 exchange nailings, 2 nail dynamisations, 3 caption graftings, 2 compression in circular frame and 1 revision of internal fixation. Three underwent adjunctive procedures at the time of marroswstim. In 18 further procedures were required following marrowstim. In 4 this involved frame adjustment, 5 underwent exchange nailing, 4 revision internal fixation, 2 additional marrowstim, 2 autologous bone grafting and 3 a course of exogen treatment.

In total 27 achieved radiological and clinical union at a mean of 9.6 months, of these ten achieved union without requiring additional intervention following marrowstim, at a mean of 5.4 months. There were no complications relating to marrowstim harvest or application.

Marrowstim appears to be a safe and relatively cheap addition to the armamentarium for treatment of non-union. However many patients require further procedures in addition to marrowstim to achieve union. Furthermore given the range of procedures this cohort of patients have undergone before and after marrowstim intervention it is difficult to draw conclusions regarding it efficacy.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_2 | Pages 7 - 7
1 Jan 2013
Khan I Nicol S Jackson M Monsell F Livingstone J Atkins R
Full Access

Lower limb mal-alignment due to deformity is a significant cause of early degenerative change and dysfunction. Standard techniques are available to determine the centre of rotation of angulation (CORA) and extent of the majority of deformities, however distal femoral deformity is difficult to assess because of the difference between anatomic and mechanical axes. We found the described technique involving constructing a line perpendicular to a line from the tip of the greater trochanter to the centre of the femoral head inaccurate, particularly if the trochanter is abnormal. We devised a novel technique which accurately determines the CORA and extent of distal femoral deformity, allowing accurate correction.

Using standard leg alignment views of the normal femur, the distal femoral metaphysis and joint line are stylized as a block. A line bisecting the axis of the proximal femur is then extended distally to intersect the joint. The angle (θ) between the joint and the proximal femoral axis and the position (p) where the extended proximal femoral axis intersects the joint line are calculated. These measurements can then be reproduced on the abnormal distal femur in order to calculate the CORA and extent of the deformity, permitting accurate correction.

We examined the utility and reproducibility of the new method using 100 normal femora. θ = 81 ± sd 2.5°. As expected, θ correlated with femoral length (r=0.74). P (expressed as the percentage of the distance from the lateral edge of the joint block to the intersection) = 61% ± sd 8%. P was not correlated with θ.

Intra-and inter-observer errors for these measurements are within acceptable limits and observations of 30-paired normal femora demonstrate similar values for θ and p on the two sides.

We have found this technique to be universally applicable and reliable in a variety of distal femoral deformities.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 16 - 16
1 May 2012
Jackson M
Full Access

Persistent pain is a common cause of disability in patients after fractures of the calcaneum. Amongst the possible causes for post traumatic pain is the development of degenerative osteoarthritis of the posterior facet of the subtalar joint. However there are many other causes of post-traumatic hindfoot pain which require consideration prior to treatment. Knowledge of the patho-anatomy of calcaneal fractures is required to reach an accurate diagnosis. Significant symptoms and disability may be treated by arthrodesis of the subtalar joint.

Post-traumatic arthritis in the non-operatively treated calcaneal fracture is however usually associated with deformity of the hindfoot, disordered hindfoot biomechanics, lateral wall fibular impingement and fibular tendon dysfunction.

Fractures treated by primary open reduction and fixation should be well aligned but despite anatomic reduction may also develop posterior facet arthritis. Symptoms may also be caused by prominence or impingement of the implant, particularly of locked perimeter plates on the lateral wall.

Patients therefore require careful assessment prior to surgery and any operative measures have to address these key features in order to produce a satisfactory clinical result.

This lecture will address the potential problems of this type of surgery and key features in the clinical assessment and imaging of these patients.

Subtalar arthrodesis in the presence of deformity is technically complex and requires careful planning in order to correct the deformity and to produce a well aligned hindfoot to allow corrected biomechanics without impingement and the fitment of suitable footwear.

The surgical techniques and different types of surgery required to adequately manage the posterior facet and deformity will be covered and will include arthroscopically assisted in-situ fusion, the safe approaches for open surgery and techniques to reconstruct the lateral wall, fibular tendon function and osteotomies required to restore calcaneal height and alignment.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 66 - 66
1 May 2012
Khan IH Nicol S Jackson M Monsell F Livingstone JA Atkins RM
Full Access

Lower limb mal-alignment due to deformity is a significant cause of early degenerative change and dysfunction. Standard techniques are available to determine the centre of rotation of angulation (CORA) and extent of the majority of deformities, however distal femoral deformity is difficult to assess because of the difference between anatomic and mechanical axes. We found the described technique involving constructing a line perpendicular to a line from the tip of the greater trochanter to the centre of the femoral head inaccurate, particularly if the trochanter is abnormal. We devised a novel technique which accurately determines the CORA and extent of distal femoral deformity, allowing accurate correction.

Using standard leg alignment views of the normal femur, the distal femoral metaphysis and joint line are stylized as a block. A line bisecting the axis of the proximal femur is then extended distally to intersect the joint. The angle (Θ) between the joint and the proximal femoral axis and the position (p) where the extended proximal femoral axis intersects the joint line are calculated. These measurements can then be reproduced on the abnormal distal femur in order to calculate the CORA and extent of the deformity, permitting accurate correction.

We examined the utility and reproducibility of the new method using 100 normal femora. Θ = 81 ± sd 2.5. As expected, Θ correlated with femoral length (r=0.74). P (expressed as the percentage of the distance from the lateral edge of the joint block to the intersection) = 61% ± sd 8%. P was not correlated with Θ.

Intra-and inter-observer errors for these measurements are within acceptable limits and observations of 30-paired normal femora demonstrate similar values for Θ and p on the two sides.

We have found this technique to be universally applicable and reliable in a variety of distal femoral deformities.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 8 - 8
1 May 2012
Gardner R Yousri T Holmes F Clark D Pollintine P Miles A Jackson M
Full Access

Treatment of syndesmotic injuries is a subject of ongoing controversy. Locking plates have been shown to provide both angular and axial stability and therefore could potentially control both shear forces and resist widening of the syndesmosis. The aim of this study is to determine whether a two-hole locking plate has biomechanical advantages over conventional screw stabilisation of the syndesmosis in this pattern of injury. Six pairs of fresh-frozen human cadaver lower legs were prepared to simulate an unstable Maisonneuve fracture. The limbs were then mounted on a servo-hydraulic testing rig and axially loaded to a peak load of 800N for 12000 cycles. Each limb was compared with its pair; one receiving stabilisation of the syndesmosis with two 4.5mm quadricortical cortical screws, the other a two-hole locking plate with 3.2mm locking screws (Smith and Nephew). Each limb was then externally rotated until failure occurred. Failure was defined as fracture of bone or metalwork, syndesmotic widening or axial migration >2mm. Both constructs effectively stabilised the syndesmosis during the cyclical loading within 1mm of movement. However the locking plate group demonstrated superior resistance to torque compared to quadricortical screw fixation (40.6Nm vs 21.2Nm respectively, p value <0.03).

Conclusion

A 2 hole locking plate (3.2mm screws) provides significantly greater stability of the syndesmosis to torque when compared with 4.5mm quadricortical fixation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XII | Pages 15 - 15
1 Apr 2012
Khan I Nicol S Jackson M Monsell F Livingstone J Atkins R
Full Access

Lower limb mal-alignment due to deformity is a significant cause of early degenerative change and dysfunction. Standard techniques are available to determine the centre of rotation of angulation (CORA) and extent of the deformities. However, distal femoral deformity is difficult to assess because of the difference between anatomic and mechanical axes. We describe a novel technique which accurately determines the CORA and extent of distal femoral deformity.

Using standard leg alignment views of the normal femur, the distal femoral metaphysis and joint line are stylised as a block. A line bisecting the anatomical axis of the proximal femur is then extended distally to intersect the joint. The angle (?) between the joint and the proximal femoral axis, and the position (p) where the extended proximal femoral axis intersects the joint line are calculated. These measurements can then be reproduced on the abnormal distal femur in order to calculate the CORA and extent of deformity, permitting accurate correction.

We examined the utility and reproducibility of the new method using 100 normal femora. We found this technique to be universally robust in a variety of distal femoral deformities.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 148 - 148
1 Mar 2012
Morgan B Livingstone J MacFadyen I Jackson M Atkins R
Full Access

Introduction

The optimal management of intra-articular tibial plateau fractures with metaphyseal-diaphyseal dissociation remains challenging and controversial. We report results using the technique of limited open reduction with external fixation using a fine wire circular frame.

Method

Between 1994 –2006, 83 eligible patients were identified. Case notes were reviewed; X-Rays and CT scans were examined and used to rank-order the severity of injury. ‘Musculoskeletal Functional Assessment’ (MFA) and ‘Knee Outcome Survey’ (KOS) questionnaires were completed and axial alignment X-Rays were taken to assess functional and radiological outcome.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 4 - 4
1 Feb 2012
Cottam H Jackson M Butler-Manuel A Apthorp H
Full Access

Aims

To compare a randomised group of patients undergoing UKA to investigate the advantages of the minimal invasive approach in the early post-operative stage.

Results

100 patients on the waiting list for UKA were recruited into the trial. Patients were prospectively randomised into 2 groups: Group 1 – longitudinal skin incision with dislocation of the patella, Group 2 – the minimally invasive approach. Standard milestones were recorded post-operatively: time to achieve IRQ, independent stair climbing and to discharge. Additionally, patients were scored with the AKSS and Oxford knee questionnaire pre-operatively, at 6 weeks, 6 months and 1 year. No significant differences were found between the 2 groups in the measured parameters.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 388 - 388
1 Jul 2011
Khan IH Nicol S Jackson M Monsell F Livingstone JA Atkins RM
Full Access

Lower limb mal-alignment due to deformity is a significant cause of early degenerative change and limb dysfunction. Standard techniques are available to determine the centre of rotation of angulation (CORA) and extent of the majority of deformities, however distal femoral deformity is difficult to assess because of the difference between the anatomic and mechanical axes. We have found the described technique involving constructing a line perpendicular to a line from the tip of the greater trochanter to the centre of the femoral head inaccurate, particularly if the trochanter is abnormal. We have devised a novel technique which accurately determines the CORA and extent of distal femoral deformity, allowing accurate correction.

Using standard leg alignment views of the normal femur, the distal femoral metaphysis and joint line are stylised as a block. A line bisecting the axis of the proximal femur is then extended distally to intersect the joint. The angle (𝛉) between the joint and the proximal femoral axis and the position (p) where the extended proximal femoral axis intersects the joint line are calculated. These measurements can then be reproduced on the abnormal distal femur in order to calculate the CORA and extent of the deformity, permitting accurate correction.

We have examined the utility and reproducibility of the new method using one hundred normal femurs. Θ=81+/− sd 2.5°. As expected, 𝛉 correlated with femoral length (r=0.74). P (expressed as the percentage of the distal from the medial edge of the joint block to the intersection) = 61% +/− sd 8%. P was not correlated with 𝛉.

Intra-and inter-observer errors for these measurements are within acceptable limits and observations of twenty paired normal femora demonstrate similar values for 𝛉 and p on the two sides.

We have employed this technique in a variety of distal femoral deformities, including vitamin D resistant rickets, growth arrest, fibula hemimelia, post-traumatic deformity and Ellis-van Creveld syndrome. We find the system universally applicable and reliable.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 315 - 315
1 Jul 2011
Barnes J Monsel F Kirubanandan R Aylott C Atkins R Jackson M Livingstone J
Full Access

Methods: A Ring Fixator (Taylor Spatial Frame (TSF); Smith & Nephew, Memphis, TN), was used in the treatment of 5 patients (ages 11 to 16 years) with proximal tibial growth arrest following trauma.

Results: The mean corrections were 14.2° (max 28°, min 0°) in the saggital plane and 14° (max 38°, min 2°) in the coronal plane. Leg length discrepancy was also corrected (max 1cm). The average time in frame was 17.8 weeks, with an average correction time of 29.8 days. Knee Society Clinical Rating System (KSCRS) scores post operatively ranged from 95 to 100. All patients returned to full activity, and would accept the same treatment if offered again. The circular fixator is an effective, minimally invasive method for treating the complex deformities arising from this rare injury. Patients remain active during treatment, encouraging a rapid return to school/work activities.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 127 - 127
1 May 2011
Yeung E Bott PT Jackson M Walter W Walter W Zicat B
Full Access

Aim: Alumina ceramic on ceramic bearings have gained popularity in hip arthroplasty due to the properties of low wear, low friction and chemically inert wear debris. In a previous study, we reported the excellent clinical results of a series of cementless ceramic on ceramic primary total hip arthroplasties at a minimum of 5 years. We now present the follow up results at 10 years.

Method: Between June 1997 and February 1999, 301 consecutive, primary cementless hip arthroplasties were performed on 283 patients in our unit. The mean age of the patients was 57.8 years, with 145 (51%) being female. All of the hips received the same implant: (Osteonic ABC cup and Secure-Fit or Secure-Fit Plus stem; Stryker Orthopaedics). A third generation alumina ceramic on ceramic bearing (Biolox Forte; CeramTec) was used for articulation in all cases. All the operations were performed through a posterior approach with enhanced posterior repair, and the post-operative protocols were the same for all the patients. The clinical and radiographic outcome at 10 years were analysed.

Results: At 10 years, 7.3% had died of unrelated cause and 3% were revised. The average Harris Hip score was 94.3 points at the last follow up. Ninety six percent of patients scored an excellent or good result, with less than 3% have moderate residual pain. Radiographically, all patients assessed had evidence of stable bony ingrowth. There were nine revisions in all, four stem revisions due to periprosthetic fracture, one secondary to aseptic loosening and one to facilitate a femoral shortening osteotomy. There was one cup revision for psoas tendonitis and one for cup repositioning. This same patient subsequently underwent further revision due to acetabular osteolysis with metallosis and some ceramic wear. Overall, the survival rate of the implants was 96% at 10 years. The retrieved femoral heads showed a median wear rate of 0.2 cubic millimeters per year.

Conclusions: Alumina ceramic on ceramic bearings in cementless primary total hip arthroplasty had been shown to have good survival rate at 10 years with good function, low wear rate and no adverse radiographic changes. The one case of osteolysis may be due to ceramic wear debris or may be due to metal wear debris from the neck to rim impingement.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 4 - 4
1 Jan 2011
McCann P Mitchell S Jackson M
Full Access

A series of 49 pilon fractures in a tertiary referral centre treated definitively with open reduction and internal fixation have been assessed examining the complications associated with such injuries. A retrospective analysis of casenotes, radiographs and computerised tomographs over a seven year period from 1999–2006 was performed.

Infection was the most common post operative problem. There were 7 cases of superficial infection. There was a single case of deep infection requiring intravenous antibiotics and removal of metalwork. Other notable complications were those of secondary osteoarthritis (three cases) and malunion (one case).

The key finding of this paper is the 2% incidence of deep infection following the direct operative approach to these fractures. The traditional operative approach to such injuries (initially advocated by Ruedi and All-gower) consisted of extensive soft tissue dissection to gain access to the distal tibia. Our preferred method is to gain access to via the “direct approach” which involves direct access to the fracture site with minimal disturbance of the soft tissue envelope. We therefore believe open reduction and internal fixation of pilon fractures via the direct approach to be an excellent technique in the treatment of such injuries.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 4 - 4
1 Jan 2011
Barnes J Monsell F Aylott C Kirubandanan R Jackson M Atkins R Livingstone J
Full Access

A Ring Fixator (Taylor Spatial Frame (TSF); Smith & Nephew, Memphis, TN), was used in the treatment of 5 patients (ages 11 to 16 years) with proximal tibial growth arrest following trauma. The mean corrections were 14.20 (max 280, min 00) in the saggital plane and 140 (max 380, min 20) in the coronal plane. Leg length discrepancy was also corrected (max 1 cm). The average time in frame was 17.8 weeks, with an average correction time of 29.8 days. Knee Society Clinical Rating System (KSCRS) scores post operatively ranged from 95 to 100. All patients returned to full activity, and would accept the same treatment if offered again.

The circular fixator is an effective, minimally invasive method of treatment for post-traumatic proximal tibial deformity. Patients remain active during treatment encouraging a rapid return to school/work activities.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 530 - 530
1 Oct 2010
Sexton S Jackson M Martell J Walter W Zicat B
Full Access

Introduction: Dislocation is the most common complication resulting in re-operation after total hip arthroplasty. This study investigates the association between acetabular prosthesis position, changes in femoral offset and leg length and the risk of dislocation.

Patients and Methods: All total hip arthroplasties performed over the past 17 years at one institution were reviewed. The posterolateral approach was used in all cases. Only hips that included all of the following were included in the study: diagnosis of primary osteoarthritis, no previous surgery, unconstrained liner. 3682 hips met the inclusion criteria. 60 hips (1.6%) sustained a dislocation. Cup inclination and version was determined from scanned radiographs using Hip Analysis Suite software (University of Chicago) in all hips that dislocated and a control group of 60 patients matched for femoral head size, sex, age at surgery, side of hip replacement, time from surgery, BMI, type of prosthesis and bearing surface. We compared femoral offset and length against the contralateral normal hip, on standardised radiographs. Therefore dislocation cases where the contralateral hip had been replaced, where arthritic changes were present, or where previous surgery had been undertaken were not included in the analysis. 24 dislocating hips were measured and compared with 48 controls matched using the same criteria as above. Radiographs were analysed using Hip Analysis Suite.

Results: There is a statistically significant difference (p=0.025) in anteversion between dislocators and matched controls. Inclination is not significantly associated with dislocation (p=0.536).

There is a relative risk of 3.0 of dislocation in cups with ≤15 degrees of anteversion compared with > 15 degrees of anteversion. This difference in dislocation is statistically significant (p< 0.01).

Increased femoral offset compared with the normal contralateral hip is statistically significantly associated with an increased risk of dislocation (p=0.03). Change in leg length is not associated with dislocation risk.

Discussion: Decreased cup anteversion is associated with an increased risk of dislocation in hips operated on via the postero-lateral approach. Our results indicate that the surgeon should aim for a minimum of 15 degrees of anteversion to reduce the risk of dislocation.

The increase in femoral offset in the prosthetic hip compared with the normal contralateral hip and its association with dislocation may be due to intraoperative attempts to compensate for an unstable hip by increasing offset. These results indicate that a surgeon should be cautious when increasing femoral offset alone to try and compensate for a potentially unstable hip. Other factors, for example acetabular version should be addressed, with readjustment of cup position intra-operatively if required.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 529 - 530
1 Oct 2010
Sexton S De Steiger R Jackson M Stanford T Walter W
Full Access

Introduction: Dislocation is the most common complication resulting in re-operation following total hip arthroplasty, accounting for 33.5% of revisions. This study investigates the relationship between bearing surface and the risk of revision due to dislocation.

Materials and Methods: Analysis was based on 110,239 primary total hip arthroplasties with a primary diagnosis of osteoarthritis. Data were collected by the Austra-lian Orthopaedic National Joint Replacement Registry from September 1999 to December 2007. The bearing surfaces were: 20627 (18.7%) ceramic-on-ceramic, 14001 (12.7%) ceramic-on-polyethylene, 12208 (11.1%) metal-on-metal, and 62437 (56.6%) metal-on-polyethylene. In 966 (0.8%) hips the bearing surface was unknown.

Results: There were 862 (0.8%) hips revised due to dislocation, with a rate of 0.3 revisions per 100 component years. Survival analysis with an end point of revision due to dislocation was performed. Revision for dislocation is potentially associated with variables other than bearing surface (including age and femoral component head size). Therefore analyses were stratified by femoral head size (≤28mm and > 28mm), and age (< 65 years and ≤65 years). There is a significantly higher rate of revision for dislocation in ceramic-on-ceramic bearing surfaces compared to metal-on-polyethylene bearing surfaces after adjustment for age, sex and head size in the head size < =28mm/Age < 65 group (hazard ratio = 1.53, 95% C.I. = 1.02 to 2.30, p=0.041) and the head size > 28mm/Age > =65 group (hazard ratio = 1.73, 95% C.I. = 1.10 to 2.74, p=0.016).

Discussion: Ceramic-on-ceramic bearing surfaces have a higher risk of revision due to dislocation in the femoral head sizes and ages discussed above, compared with metal-on-polyethylene. Possible mechanisms for this observed difference may include patient selection, the limits to head and liner offset options when using ceramic bearing surfaces or higher rates of revision after dislocation due to ceramic head or liner damage. However our results are based on a seven year follow-up, and higher rates of late dislocation with polyethylene bearings may be observed in association with higher wear rates compared with ceramic liners.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 79 - 79
1 Mar 2009
Kelley S Rogers M Morgan B Jackson M
Full Access

INTRODUCTION – Tuberosity fractures of the calcaneum are rare injuries. The traditional operative treatment involves open reduction and internal fixation with a tension band wire construct. We have developed a new technique of fixing these fractures with internal fixation using cannulated screws and a figure of eight wire. This paper describes the new technique outlining its advantages and compares the 2 methods of fixation biomechanically to determine their properties with respect to fracture fixation.

METHOD – 20 sections of bovine bone were taken to act as an experimental model for the calcaneum. They were osteotomised to create the posterior process fracture model. 10 were fixed using a traditional tension band wire construct and 10 were fixed using the cannulated screw and wire construct. Each construct was subjected to biomechanical testing to identify the stiffness, energy to failure and load to failure.

RESULTS – During loading the cannulated screw and wire constructs showed a significant increase in stiffness and energy to failure compared to the tension band wire constructs

CONCLUSION – The increased stability of the cannulated screw construct demonstrated by the testing offers biomechanical benefit over the traditional tension band wire construct. This, as well as the improved technical aspects of the cannulated screw fixation, may be beneficial for clinical use.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 504 - 504
1 Aug 2008
Morgan B Rogers MJ Jackson M Livingstone J Monsell F Atkins R
Full Access

17 patients have undergone 20 microdrilling procedures to stimulate bone union in cases of established non-union. This occurred at the docking site following completion of bone transport using a stacked Taylor Spatial Frame, non-union following arthrodesis or non-union in long bone fracture.

Additional bone grafting was performed in only one patient. Further stimulation of union via injection of Bone Morphogenetic Protein was undertaken with 3 microdrilling procedures.

Of the 20 microdrilling procedures, 8 were considered fully successful in terms of stimulation of union, 7 were partially successful and 5 were not felt to have been successful.

The mean time to fully successful union following microdrilling was 11.4 weeks, ranging from 6 to 19 weeks.

There were 2 complications, both acute infections at the microdrilling site. Both of these were in patients with previous significant pin site infections.

We present the use of a microdrilling technique as a safe and effective minimally invasive technique that promotes union in cases of refractory non-union, whilst avoiding the donor site morbidity associated with open bone grafting.

We present, as a pilot study, our experience in the use of this technique in patients treated with circular frames for acute fractures, at the docking site in cases of bone transport and in cases of non-union following arthrodesis.