Higgs ZCJ Danks BA Sibinski M Rymaszewski LA

The use of passive stretching of the elbow after arthrolysis is controversial. We report the results of open arthrolysis in 81 patients. Prospectively collected outcome data with a minimum follow-up of one year were analysed. All patients had sustained an intra-articular fracture initially and all procedures were performed by the same surgeon under continuous brachial plexus block anaesthesia and with continuous passive movement (CPM) used post-operatively for two to three days. CPM was used to maintain the movement achieved during surgery and passive stretching was not used at any time. A senior physiotherapist assessed all the patients at regular intervals. The mean range of movement (ROM) improved from 69° to 109° and the function and pain of the upper limb improved from 32 to 16 and from 20 to 10, as assessed by the Disabilities of the Arm Shoulder and Hand score and a visual analogue scale, respectively. The greatest improvement was obtained in the stiffest elbows: nine patients with a pre-operative ROM < 30° achieved a mean post-operative ROM of 92° (55° to 125°). This study demonstrates that in patients with a stiff elbow after injury, good results may be obtained after open elbow arthrolysis without using passive stretching during rehabilitation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 349 - 349
1 Jul 2008
Higgs ZCJ Danks B Sibinski M Rymaszewski L
Full Access

Over the last 15 years there have been a series of publications reporting the beneficial effects of elbow arthrolysis, with considerable variation in operative technique and post-operative management.

Aim. To assess the results of open elbow arthrolysis in patients who did not receive any physiotherapy after discharge from hospital, although this is routinely prescribed by many surgeons.

Patients and Methods. Prospectively collected data of 34 patients with a minimum follow-up of 1 year after arthrolysis was analysed. All the procedures were performed by the same surgeon, achieving as much improvement in elbow motion as possible at operation. All the patients had continuous brachial plexus blocks and continual passive motion for 2–3 days postoperatively but none received any physiotherapy after discharge. At review, a senior physiotherapist formally assessed all the patients, including measuring elbow motion with a goniometer.

Results. All patients’ arc of movement improved from, with mean elbow flexion increasing by 16 degrees and extension 20 degress at the last follow-up. Upper limb function, assessed with a Disabilities of the Arm, Shoulder and Hand score (DASH), had improved 30%. Pain had decreased from 4.8 to 3.1 using the Visual Analogue Score. The greatest improvement in motion was obtained in the stiffest elbows – 5 patients with an arc of 30 degrees or less pre-operatively achieved an arc of 96 degrees by the time of the last review. Only early complications occurred – ulnar neuritis and significant pain – but these symptoms had largely settled by the time of the last review.

Conclusions. Good results of open arthrolysis for post-traumatic elbow stiffness can be achieved with continuous brachial plexus blocks and continual passive motion for 2–3 days post-operatively. There appears to be little evidence to support formal treatment with physiotherapy after discharge from hospital, as our results are similar to other reported series.