Aim

In patients with bone sarcoma, placing mega prostheses in the proximal tibia is associated with high rates of infection. In studies with small numbers of patients and short follow-up periods, silver-coated mega prostheses have been reported to lead to reduced infection rates. To the best of our knowledge, this study is the largest one that has compared the infection rates with titanium versus silver-coated mega prostheses in patients treated for sarcomas in the proximal tibia.

Method

The infection rate in 98 patients with sarcoma or giant cell tumour in the proximal tibia who underwent placement of a titanium (n = 42) or silver-coated (n = 56) mega prosthesis* was assessed, along with the treatments administered for any infection.