header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 72 - 72
1 Dec 2016
Karlsen ØE Borgen P Bragnes BO Figved W Grøgaard B Rydinge J Sandberg L Snorrason F Wangen H Witso E Westberg M
Full Access

Aim

Prosthetic joint infection (PJI) is a much feared complication to arthroplasty with significant patient morbidity. Rifampin is increasingly used in staphylococcal PJIs treated with debridement and retention of the prosthesis. The evidence supporting rifampin combination therapy in PJIs is limited due to the lack of controlled studies. The aim of this study is to evaluate the effect of adding rifampin to conventional antimicrobial therapy in early staphylococcal PJIs treated with debridement and retention.

Method

In this multicentre randomized controlled trial, 99 patients with PJI after hip and knee arthroplasties were enrolled. All patients underwent a standardized surgical debridement. 65 patients had PJI caused by staphylococci and further included in the study. They were randomly assigned to receive rifampin or not in addition to standard antimicrobial therapy with cloxacillin, or vancomycin in case of methicillin resistance. They received parenteral antibiotics for two weeks, then oral antibiotics for 4 weeks. In case of methicillin resistance, vancomycin was administered i.v. for 6 weeks. The primary end point was no signs of infection after 2 wears follow-up.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 151 - 151
1 Jul 2014
van Leeuwen J Röhrl S Grøgaard B Snorrason F
Full Access

Summary Statement

Our data suggest that postoperative component positioning in TKA with PSPG is not consistent with pre-operative software planning. More studies are needed to rule out possible learning curve in this study.

Introduction

Patient specific positioning guides (PSPGs) in TKA are based on MRI or CT data. Preoperatively, knee component positions can be visualised in 3-dimensional reconstructed images. Software allows anticipation of component position. From software planning PSPGs are manufactured and those PSPGs represent intra-operative component alignment. To our knowledge, there are no studies comparing pre-operative software planning with post-operative alignment. Aim of this study is to investigate the correlation between pre-operative planning of component positioning and the post-operative achieved alignment with PSPG technique.